Helena Zelikman

Dr. Helena Zelikman


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in Materials
Verified
Journal Article
Open access
PDF file
AMAvi Meirowitz
Avi Meirowitz
ARArkadi Rahmanov
Arkadi Rahmanov
ESEti Shlomo
Eti Shlomo
HZHelena Zelikman
Helena Zelikman
EDeran dolev
eran dolev
NSNir Sterer
Nir Sterer
Denture stomatitis is a common manifestation of oral candidiasis affecting some 65% of denture wearers. This condition is initiated by the adherence of Candida albicans to denture base acrylic resin. The present study aimed to test the in vitro effect of traditional and novel fabrication methods on Candida albicans adhesion to denture base samples. Denture based acrylic discs were fabricated using: (i) computerized milling, (ii) 3D printing, (iii) heat curing, and (iv) cold curing. Discs were tested for surface roughness (Ra), hydrophobicity (contact angle), mucin adsorption (Bradford assay), and Candida albicans adhesion. 3D printing significantly increased microbial cell adhesion as compared with heat curing, and computerized milling significantly decreased it. These results were associated with mucin adsorption levels rather than surface roughness. Results suggest that 3D printing may increase the risk for developing denture stomatitis, whereas computerized milling may decrease it as compared with traditional heat curing denture base fabrication.

18 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
HZHelena Zelikman
Helena Zelikman
GSGil Slutzkey
Gil Slutzkey
ORofir rosner
ofir rosner
SLShifra Levartovsky
Shifra Levartovsky
Shlomo MatalonShlomo Matalon
Shlomo Matalon
IBIlan Beitlitum
Ilan Beitlitum
GBR (Guided Bone Regeneration) procedure is challenged by the risk of membrane exposure to the oral cavity and contamination. The barrier quality of these membranes serve as a mechanical block from bacterial penetration into the GBR site. The purpose of this in vitro study was to evaluate the antibacterial effect of three commercial non-resorbable polytetrafluoroethylene membranes. (Two d-PTFE membranes and one double layer e-PTFE +d-PTFE membrane). A validated in vitro model with two bacterial species (Streptococcus sanguinis and Fusobacterium nucleatum) was used. Eight samples from membrane each were placed in a 96-well microtiter plate. The experimental and positive control groups were exposed to a bacterial suspension which involved one bacterial species in each plate. Bacterial growth was monitored spectrophotometrically at 650 nm for 24 h in temperature controlled microplate spectrophotometer under anaerobic conditions. One- Sample Kolmogorov–Smirnov Normal test and the Kruskal–Wallis test was used for the statistical analysis. As shown by the bacterial growth curves obtained from the spectrophotometer readings, all three membranes resulted in bacterial growth. We have not found a statistical difference in F. nucleatum growth between different membrane samples and the positive control group. However, S. sanguinis growth was reduced significantly in the presence of two membranes (CYTOPLAST TXT-200 and NeoGenTM) when compared to the control (p < 0.01). The presence of Permamem® had no significant influence on S. sanguinis growth. Some types of commercial non-resorbable PTFE membranes may have an impact on the growth dynamics of specific bacterial species.

9 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SNSarit Adriana Naishlos
Sarit Adriana Naishlos
EZEran Zenziper
Eran Zenziper
HZHelena Zelikman
Helena Zelikman
Joseph NissanJoseph Nissan
Joseph Nissan
SMShaked Mizrahi
Shaked Mizrahi
LCLiat Chaushu
Liat Chaushu
Background: Various conditions may lead to bony deficiency in the anterior maxilla. The present study evaluated esthetic (PES—pink esthetic score and WES—white esthetic score) results after augmentation of the anterior atrophic maxilla using cancellous bone-block allograft followed by implant placement and late (conventional) loading. Methods: Cohort study that included 33 patients with missing teeth in the upper anterior region characterized by extensive bone loss. Allogeneic cancellous bone-blocks were used for augmentation. Six months later, a dental implant was inserted. After a waiting time of an additional six-months, implant exposure and reconstruction were performed. The mean follow-up period was 62.93 ± 17.37 months (range 19–82 months). Results: The mean value of PES/WES was 17.8 ± 2.78. All patients had a PES/WES value above 12 (threshold value defined as clinically acceptable esthetics). The mean value of PES was 9.0 ± 1.79 and the mean value of WES was 8.8 ±1.84. Conclusions: Bone augmentation of the anterior atrophic maxilla using cancellous block-allograft and late loading supports achievement of a predictable esthetic result with long-term stability of soft and hard tissues around implant-supported reconstructions.

26 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HZHelena Zelikman
Helena Zelikman
ORofir rosner
ofir rosner
SNSarit Adriana Naishlos
Sarit Adriana Naishlos
HAHanaa Azem
Hanaa Azem
IMIsabelle Meinster
Isabelle Meinster
Shlomo MatalonShlomo Matalon
Shlomo Matalon
Two critical factors that influence the accuracy of an impression include the proper manipulation of the impression materials and the technique used to make the impression. The purpose of this study was to clinically evaluate the effect of different mixing techniques on the accuracy of vinyl polysiloxane (VPS) impressions by assessing metal framework fit of fixed partial restorations. The study included 92 consecutive patients diagnosed with partial edentulism and treated with fixed partial denture restorations. The mixing technique was one of the two following mixing methods: hand mixing technique (45 patients), with the putty material mixed according to the manufacturer’s instructions; or mechanical mixing technique (47 patients), with the putty material mixed by a Pentamix device. Under both mixing methods, vinyl polysiloxane was used as the impression material. Two impression techniques were randomly used by the operators (One/Two-stage putty –wash impression techniques). The accuracy of the metal framework restorations was tested clinically and radiologically, resulting in significant statistical difference (p = 0.04) between different mixing techniques. The mechanical mixing produced more accurate restorations (metal framework misfit only in 14.9% of patients vs. hand mixing 31.1%). Regarding the impression techniques, the two-stage impression technique was found to be significantly more accurate (p = 0.04), resulting in 14.6% ill-fitted metal frameworks vs. 31.8%, in the one-stage technique. It can be concluded that mechanical mixing yields more accurate impressions leading to more accurate restorations, especially when combined with two-stage impression technique.

21 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
Joseph NissanJoseph Nissan
Joseph Nissan
ORofir rosner
ofir rosner
GRGal Rosen
Gal Rosen
SNSarit Adriana Naishlos
Sarit Adriana Naishlos
EZEran Zenziper
Eran Zenziper
LCLiat Chaushu
Liat Chaushu
Impression technique is one of the factors affecting restoration fit accuracy, which is a major aspect influencing its survival. The purpose of this study is to compare, in vivo, the effect of two commonly used Vinyl Polysiloxane (VPS) impression techniques on the metal framework fitting of fixed partial dentures. Ninety-two consecutive patients, diagnosed as partially edentulous, treated by fixed partial denture restorations, participated in the study. Group 1-impressions (n = 44) were subjected to the 1-step technique, while group 2 impressions (n = 48) were subjected the 2-step technique. Three accuracy assessment common methods: probe, tactile sense and radiographic test, were used to validate the clinical fit of the metal framework. Misfit was defined as even one test failure. Twenty-one (22.8%) out of 92 metal frameworks exhibited metal frameworks misfit, whereas the other 71 (77.2%) were found to be accurate. Group 1 presented significantly (p = 0.04) more metal frameworks misfit, 14/44 (31.8%) vs. 7/48 (14.6%). Restoration location (maxilla vs. mandible) had no statistically significant impact on the results (p = 0.461). The use of the VPS putty/wash 2-step impression technique is recommended to improve the clinical fit of fixed partial denture restorations.

14 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASasaf shely
asaf shely
SLshiri livne
shiri livne
GBGil Ben-izhack
Gil Ben-izhack
MLMichal Lokshin
Michal Lokshin
SHShahar Har-Nes
Shahar Har-Nes
EDeran dolev
eran dolev
Background: The purpose of this in vitro study was to compare the implant axis’ spatial position and orientation by using laboratory scanner versus intra-oral scanner with three different scan abutments. Methods: A 3D model was printed with an internal hex implant analog in the place of teeth 35#. Three standard scan abutments were used: MIS (two-piece titanium), AB (two-piece PEEK and titanium base) and ZZ (one-piece PEEK). Each scan abutment was scanned 30 times by TRIOS E3 (laboratory scanner) and 30 times by Omnicam (intra-oral scanner). For each scan, an STL (stereolithography) file was created, and the spatial characterization of each scan abutment was measured in the X, Y, Z coordinates, and rotational and longitudinal angles. The comparison between all the scans was conducted by superimposition of the STL files, using a 3D software. A t-test and Wilcoxon signed-rank test were used. (p < 0.05) Results: Only the MIS scan abutment showed no statistical difference in the X and Z axes. (p < 0.05). All other scan abutments showed a statistical difference in all axes. The rotational angle of the AB scan abutment was twice the angle of the MIS and ZZ scan abutments. Conclusions: All three scan abutments showed a rotational deviation of the implant axis between the laboratory scanner and the intra-oral scanner. The AB scan abutment showed the greatest deviation (1.04 degrees) while the other two abutments showed deviations of about half a degree in relation to the laboratory scan abutment. There is a need for further studies which will examine the influence of geometry, material, and scan abutment parts on the accuracy of the scan obtained.