ofir rosner

Dr. ofir rosner


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
HZHelena Zelikman
Helena Zelikman
GSGil Slutzkey
Gil Slutzkey
ORofir rosner
ofir rosner
SLShifra Levartovsky
Shifra Levartovsky
Shlomo MatalonShlomo Matalon
Shlomo Matalon
IBIlan Beitlitum
Ilan Beitlitum
GBR (Guided Bone Regeneration) procedure is challenged by the risk of membrane exposure to the oral cavity and contamination. The barrier quality of these membranes serve as a mechanical block from bacterial penetration into the GBR site. The purpose of this in vitro study was to evaluate the antibacterial effect of three commercial non-resorbable polytetrafluoroethylene membranes. (Two d-PTFE membranes and one double layer e-PTFE +d-PTFE membrane). A validated in vitro model with two bacterial species (Streptococcus sanguinis and Fusobacterium nucleatum) was used. Eight samples from membrane each were placed in a 96-well microtiter plate. The experimental and positive control groups were exposed to a bacterial suspension which involved one bacterial species in each plate. Bacterial growth was monitored spectrophotometrically at 650 nm for 24 h in temperature controlled microplate spectrophotometer under anaerobic conditions. One- Sample Kolmogorov–Smirnov Normal test and the Kruskal–Wallis test was used for the statistical analysis. As shown by the bacterial growth curves obtained from the spectrophotometer readings, all three membranes resulted in bacterial growth. We have not found a statistical difference in F. nucleatum growth between different membrane samples and the positive control group. However, S. sanguinis growth was reduced significantly in the presence of two membranes (CYTOPLAST TXT-200 and NeoGenTM) when compared to the control (p < 0.01). The presence of Permamem® had no significant influence on S. sanguinis growth. Some types of commercial non-resorbable PTFE membranes may have an impact on the growth dynamics of specific bacterial species.

23 June 2024 in Molecules
Verified
Journal Article
Open access
PDF file
ORofir rosner
ofir rosner
SLshiri livne
shiri livne
MBMaria Bsharat
Maria Bsharat
SDShir Dviker
Shir Dviker
UJUziel עוזיאל Jeffet
Uziel עוזיאל Jeffet
NSNir Sterer
Nir Sterer
Oral malodor still constitutes a major challenge worldwide. A strong effort is invested in eliminating volatile sulfur compound-producing oral bacteria through organic natural products such as essential oils. Fusobacterium nucleatum is a known volatile sulfur compound-producing bacteria that inspires oral malodor. The aim of the present study was to test the effect of lavender essential oil on the bacterium’s ability to produce volatile sulfide compounds, the principal components of oral malodor. Lavender (Lavandula angustifolia) essential oil was extracted by hydrodistillation and analyzed using GC-MS. The minimal inhibitory concentration (MIC) of lavender essential oil on Fusobacterium nucleatum was determined in a previous trial. Fusobacterium nucleatum was incubated anaerobically in the presence of sub-MIC, MIC, and above MIC concentrations of lavender essential oil, as well as saline and chlorhexidine as negative and positive controls, respectively. Following incubation, volatile sulfur compound levels were measured using GC (Oralchroma), and bacterial cell membrane damage was studied using fluorescence microscopy. Chemical analysis of lavender essential oil yielded five main components, with camphor being the most abundant, accounting for nearly one-third of the total lavender essential oil volume. The MIC (4 µL/mL) of lavender essential oil reduced volatile sulfur compound secretion at a statistically significant level compared to the control (saline). Furthermore, the level of volatile sulfur compound production attributed to 1 MIC of lavender essential oil was in the range of the positive control chlorhexidine with no significant difference. When examining bacterial membrane damage, 2 MIC of lavender essential oil (i.e., 8 µL/mL) demonstrated the same, showing antibacterial membrane damage values comparative to chlorhexidine. Since lavender essential oil was found to be highly effective in hindering volatile sulfur compound production by Fusobacterium nucleatum through the induction of bacterial cell membrane damage, the results suggest that lavender essential oil may be a suitable alternative to conventional chemical-based anti-malodor agents.

20 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASasaf shely
asaf shely
DLDiva Lugassy
Diva Lugassy
ORofir rosner
ofir rosner
EZEran Zenziper
Eran Zenziper
Joseph NissanJoseph Nissan
Joseph Nissan
GBGil Ben-izhack
Gil Ben-izhack
Background: The purpose of this in vitro study was to compare the inter-implant distance, inter-implant axis, and intra-implant axis of three implants in a straight line by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS) with two different intra-oral scan bodies (ISBs). Methods: A 3D model was printed with internal hex implant analogs of three implants in positions 15#, 16#, and 17#. Two standard intra-oral scan bodies (ISBs) were used: MIS ISB (two-piece titanium) and Zirkonzhan ISB (two-piece titanium). Both ISBs were scanned using 7 Series dental wings (LBS) and 30 times using Primescan (IOS). For each scan, a stereolithography (STL) file was created and a comparison between all the scans was performed through superimposition of the STL files by using 3D analysis software (PolyWorks® 2020; InnovMetric, Québec, QC, Canada). A Kolmogorov–Smirnov test was performed followed by a Mann–Whitney test (p < 0.05). Results: The change in inter-implant distance for the MIS ISB was significantly lower compared to the ZZ (p < 0.05). The change in intra-implant angle was significantly lower for the ZZ ISB compared to MIS (p < 0.05). The changes in inter-implant angle between the mesial and middle and between the middle and distal were significantly lower for MIS compared to ZZ in contrast to mesial to distal, which was significantly higher (p < 0.05). Conclusions: Both ISBs showed differences in all the parameters between the LBS and the IOS. The geometry of the scan abutment had an impact on the inter-implant distance as the changes in the inter-implant distance were significantly lower for the MIS ISB. The changes in the intra-implant angle were significantly lower for the ZZ ISB. There is a need for further research examining the influence of geometry, material, and scan abutment parts on the trueness.

26 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HZHelena Zelikman
Helena Zelikman
ORofir rosner
ofir rosner
SNSarit Adriana Naishlos
Sarit Adriana Naishlos
HAHanaa Azem
Hanaa Azem
IMIsabelle Meinster
Isabelle Meinster
Shlomo MatalonShlomo Matalon
Shlomo Matalon
Two critical factors that influence the accuracy of an impression include the proper manipulation of the impression materials and the technique used to make the impression. The purpose of this study was to clinically evaluate the effect of different mixing techniques on the accuracy of vinyl polysiloxane (VPS) impressions by assessing metal framework fit of fixed partial restorations. The study included 92 consecutive patients diagnosed with partial edentulism and treated with fixed partial denture restorations. The mixing technique was one of the two following mixing methods: hand mixing technique (45 patients), with the putty material mixed according to the manufacturer’s instructions; or mechanical mixing technique (47 patients), with the putty material mixed by a Pentamix device. Under both mixing methods, vinyl polysiloxane was used as the impression material. Two impression techniques were randomly used by the operators (One/Two-stage putty –wash impression techniques). The accuracy of the metal framework restorations was tested clinically and radiologically, resulting in significant statistical difference (p = 0.04) between different mixing techniques. The mechanical mixing produced more accurate restorations (metal framework misfit only in 14.9% of patients vs. hand mixing 31.1%). Regarding the impression techniques, the two-stage impression technique was found to be significantly more accurate (p = 0.04), resulting in 14.6% ill-fitted metal frameworks vs. 31.8%, in the one-stage technique. It can be concluded that mechanical mixing yields more accurate impressions leading to more accurate restorations, especially when combined with two-stage impression technique.

21 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
Joseph NissanJoseph Nissan
Joseph Nissan
ORofir rosner
ofir rosner
GRGal Rosen
Gal Rosen
SNSarit Adriana Naishlos
Sarit Adriana Naishlos
EZEran Zenziper
Eran Zenziper
LCLiat Chaushu
Liat Chaushu
Impression technique is one of the factors affecting restoration fit accuracy, which is a major aspect influencing its survival. The purpose of this study is to compare, in vivo, the effect of two commonly used Vinyl Polysiloxane (VPS) impression techniques on the metal framework fitting of fixed partial dentures. Ninety-two consecutive patients, diagnosed as partially edentulous, treated by fixed partial denture restorations, participated in the study. Group 1-impressions (n = 44) were subjected to the 1-step technique, while group 2 impressions (n = 48) were subjected the 2-step technique. Three accuracy assessment common methods: probe, tactile sense and radiographic test, were used to validate the clinical fit of the metal framework. Misfit was defined as even one test failure. Twenty-one (22.8%) out of 92 metal frameworks exhibited metal frameworks misfit, whereas the other 71 (77.2%) were found to be accurate. Group 1 presented significantly (p = 0.04) more metal frameworks misfit, 14/44 (31.8%) vs. 7/48 (14.6%). Restoration location (maxilla vs. mandible) had no statistically significant impact on the results (p = 0.461). The use of the VPS putty/wash 2-step impression technique is recommended to improve the clinical fit of fixed partial denture restorations.

18 April 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GBGil Ben-izhack
Gil Ben-izhack
ORofir rosner
ofir rosner
EZEran Zenziper
Eran Zenziper
Joseph NissanJoseph Nissan
Joseph Nissan
Reema HosaryReema Hosary
Reema Hosary
ASasaf shely
asaf shely
Background: In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). Methods: Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line). Standard intra-oral scan bodies (ISBs) were used, and the two models were scanned using 7 Series dental wings (LBS, reference model), followed by ten scans with Primescan (digital method). Standard Tessellation Language (STL) files were created. Five polyether impressions were taken from each model (straight and curved), and gypsum type 4 models were poured; each model was scanned five times to create a total of 25 STL files for each group (conventional method). The comparison between all the STL files (conventional and digital) was made by superimposition of the STL files on the STL reference model laboratory file using a 3D analyzing software. A Kolmogorov–Smirnov test was performed, followed by Mann–Whitney tests and Wilcoxon signed-rank tests. (p < 0.05). Results: For the conventional method, the mean errors were significantly higher for the curved line model (12–14) compared to the straight line model (15–17) for most parameters (p < 0.05). For the digital method, the mean errors were significantly higher for the curved-line model (12–14) compared to the straight line model (15–17) in half of the parameters (p < 0.05). Within the curved line model (12–14) and the straight line model (15–17), the mean errors between the conventional method and the digital method were not significant for most variables. Conclusions: The difference between curved lines and straight lines has an impact on the mean error of the conventional method. Both methods are reliable for straight and curved lines in partially dentate situations.