Lindsay Underhill

Ms. Lindsay Underhill


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Environmental Health Perspectives
Verified
Journal Article
Closed access
MJMichael A. Johnson
Michael A. Johnson
KSkyle steenland
kyle steenland
RPRicardo Piedrahita
Ricardo Piedrahita
MCMaggie Clark
Maggie Clark
APAjay Pillarisetti
Ajay Pillarisetti
HIHAPIN Investigators
HAPIN Investigators

20 January 2020 in Journal of Exposure Science & Environmental Epidemiology
Verified
Journal Article
Closed access
PDF file
LULindsay Underhill
Lindsay Underhill
WDW. Stuart Dols
W. Stuart Dols
SLSharon K. Lee
Sharon K. Lee
MFM. Patricia Fabian
M. Patricia Fabian
JLJonathan I. Levy
Jonathan I. Levy

15 January 2022 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Open access
SSSuzanne Simkovich
Suzanne Simkovich
LULindsay Underhill
Lindsay Underhill
MKMiles A. Kirby
Miles A. Kirby
MCMary E. Crocker
Mary E. Crocker
DGDina Goodman
Dina Goodman
WCWilliam Checkley
William Checkley
Rationale: Pneumonia is the leading cause of death in children worldwide. Identifying and appropriately managing severe pneumonia in a timely manner improves outcomes. Little is known about the readiness of healthcare facilities to manage severe pediatric pneumonia in low-resource settings. Objectives: As part of the HAPIN (Household Air Pollution Intervention Network) trial, we sought to identify healthcare facilities that were adequately resourced to manage severe pediatric pneumonia in Jalapa, Guatemala (J-GUA); Puno, Peru (P-PER); Kayonza, Rwanda (K-RWA); and Tamil Nadu, India (T-IND). We conducted a facility-based survey of available infrastructure, staff, equipment, and medical consumables. Facilities were georeferenced, and a road network analysis was performed. Measurements and Main Results: Of the 350 healthcare facilities surveyed, 13% had adequate resources to manage severe pneumonia, 37% had pulse oximeters, and 44% had supplemental oxygen. Mean (±SD) travel time to an adequately resourced facility was 41 ± 19 minutes in J-GUA, 99 ± 64 minutes in P-PER, 40 ± 19 minutes in K-RWA, and 31 ± 19 minutes in T-IND. Expanding pulse oximetry coverage to all facilities reduced travel time by 44% in J-GUA, 29% in P-PER, 29% in K-RWA, and 11% in T-IND (all P < 0.001). Conclusions: Most healthcare facilities in low-resource settings of the HAPIN study area were inadequately resourced to care for severe pediatric pneumonia. Early identification of cases and timely referral is paramount. The provision of pulse oximeters to all health facilities may be an effective approach to identify cases earlier and refer them for care and in a timely manner.

LULindsay Underhill
Lindsay Underhill
SBSonali Bose
Sonali Bose
DWD'ann Williams
D'ann Williams
KRKarina M. Romero
Karina M. Romero
GMGary Malpartida
Gary Malpartida
NHNadia Hansel
Nadia Hansel
The influence of traffic-related air pollution on indoor residential exposure is not well characterized in homes with high natural ventilation in low-income countries. Additionally, domestic allergen exposure is unknown in such populations. We conducted a pilot study of 25 homes in peri-urban Lima, Peru to estimate the effects of roadway proximity and season on residential concentrations. Indoor and outdoor concentrations of particulate matter (PM2.5), nitrogen dioxide (NO2), and black carbon (BC) were measured OPEN ACCESS Int. J. Environ. Res. Public Health 2015, 12 13467 during two seasons, and allergens were measured in bedroom dust. Allergen levels were highest for dust mite and mouse allergens, with concentrations above clinically relevant thresholds in over a quarter and half of all homes, respectively. Mean indoor and outdoor pollutant concentrations were similar (PM2.5: 20.0 vs. 16.9 μg/m3, BC: 7.6 vs. 8.1 μg/m3, NO2: 7.3 vs. 7.5 ppb), and tended to be higher in the summer compared to the winter. Road proximity was significantly correlated with overall concentrations of outdoor PM2.5 (rs = −0.42, p = 0.01) and NO2 (rs = −0.36, p = 0.03), and outdoor BC concentrations in the winter (rs = −0.51, p = 0.03). Our results suggest that outdoor-sourced pollutants significantly influence indoor air quality in peri-urban Peruvian communities, and homes closer to roadways are particularly vulnerable.

27 December 2017 in Indoor Air
Verified
Journal Article
Closed access
PDF file
LULindsay Underhill
Lindsay Underhill
MFM. Patricia Fabian
M. Patricia Fabian
KVK. Vermeer
K. Vermeer
MSM. Sandel
M. Sandel
GAG. Adamkiewicz
G. Adamkiewicz
JLJonathan Levy
Jonathan Levy

MFM. Patricia Fabian
M. Patricia Fabian
SLSharon Lee
Sharon Lee
LULindsay Underhill
Lindsay Underhill
KVKimberly Vermeer
Kimberly Vermeer
GAGary Adamkiewicz
Gary Adamkiewicz
JLJonathan Levy
Jonathan Levy
Secondhand exposure to environmental tobacco smoke (ETS) in multifamily housing remains a health concern despite strong recommendations to implement non-smoking policies. Multiple studies have documented exposure to ETS in non-smoking units located in buildings with smoking units. However, characterizing the magnitude of ETS infiltration or measuring the impact of building interventions or resident behavior on ETS is challenging due to the complexities of multifamily buildings, which include variable resident behaviors and complex airflows between numerous shared compartments (e.g., adjacent apartments, common hallways, elevators, heating, ventilating and air conditioning (HVAC) systems, stack effect). In this study, building simulation models were used to characterize changes in ETS infiltration in a low income, multifamily apartment building in Boston which underwent extensive building renovations targeting energy savings. Results suggest that exterior wall air sealing can lead to increases in ETS infiltration across apartments, while compartmentalization can reduce infiltration. The magnitude and direction of ETS infiltration depends on apartment characteristics, including construction (i.e., level and number of exterior walls), resident behavior (e.g., window opening, operation of localized exhaust fans), and seasonality. Although overall ETS concentrations and infiltration were reduced post energy-related building retrofits, these trends were not generalizable to all building units. Whole building smoke-free policies are the best approach to eliminate exposure to ETS in multifamily housing.