Kazunori Hoshino

Dr. Kazunori Hoshino

Biomedical Engineering Department, University of Connecticut, 260 Glenbrook Rd Unit 3247, Storrs, CT 06269-3247, USA
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Bioactive Materials
Verified
Journal Article
Open access
SSScott Stratton
Scott Stratton
NSNamdev B. Shelke
Namdev B. Shelke
KHKazunori Hoshino
Kazunori Hoshino
SRSwetha Rudraiah
Swetha Rudraiah
Sangmesh KumbarSangmesh Kumbar
Sangmesh Kumbar
A variety of engineered scaffolds have been created for tissue engineering using polymers, ceramics and their composites. Biomimicry has been adopted for majority of the three-dimensional (3D) scaffold design both in terms of physicochemical properties, as well as bioactivity for superior tissue regeneration. Scaffolds fabricated via salt leaching, particle sintering, hydrogels and lithography have been successful in promoting cell growth in vitro and tissue regeneration in vivo. Scaffold systems derived from decellularization of whole organs or tissues has been popular due to their assured biocompatibility and bioactivity. Traditional scaffold fabrication techniques often failed to create intricate structures with greater resolution, not reproducible and involved multiple steps. The 3D printing technology overcome several limitations of the traditional techniques and made it easier to adopt several thermoplastics and hydrogels to create micro-nanostructured scaffolds and devices for tissue engineering and drug delivery. This review highlights scaffold fabrication methodologies with a focus on optimizing scaffold performance through the matrix pores, bioactivity and degradation rate to enable tissue regeneration. Review highlights few examples of bioactive scaffold mediated nerve, muscle, tendon/ligament and bone regeneration. Regardless of the efforts required for optimization, a shift in 3D scaffold uses from the laboratory into everyday life is expected in the near future as some of the methods discussed in this review become more streamlined.

24 August 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
KHKazunori Hoshino
Kazunori Hoshino
YHYu-Yen Huang
Yu-Yen Huang
NLNancy Lane
Nancy Lane
MHMichael Huebschman
Michael Huebschman
JUJonathan W. Uhr
Jonathan W. Uhr
XZXiaojing Zhang
Xiaojing Zhang
Screening for circulating tumor cells (CTCs) in blood has been an object of interest for evidence of progressive disease, status of disease activity, recognition of clonal evolution of molecular changes and for possible early diagnosis of cancer. We describe a new method of microchip-based immunomagnetic CTC detection, in which the benefits of both immunomagnetic assay and the microfluidic device are combined. As the blood sample flows through the microchannel closely above arrayed magnets, cancer cells labeled with magnetic nanoparticles are separated from blood flow and deposited at the bottom wall of the glass coverslip, which allows direct observation of captured cells with a fluorescence microscope. A polydimethylsiloxane (PDMS)-based microchannel fixed on a glass coverslip was used to screen blood samples. The thin, flat dimensions of the microchannel, combined with the sharp magnetic field gradient in the vicinity of arrayed magnets with alternate polarities, lead to an effective capture of labeled cells. Compared to the commercially available CellSearch™ system, fewer (25%) magnetic particles are required to achieve a comparable capture rate, while the screening speed (at an optimal blood flow rate of 10 mL h−1) is more than five times faster than those reported previously with a microchannel-based assay. For the screening experiment, blood drawn from healthy subjects into CellSave™ tubes was spiked with cultured cancer cell lines of COLO205 and SKBR3. The blood was then kept at room temperature for 48 hours before the screening, emulating the actual clinical cases of blood screening. Customized Fe3O4 magnetic nanoparticles (Veridex Ferrofluid™) conjugated to anti-epithelial cell adhesion molecule (EpCAM) antibodies were introduced into the blood samples to label cancer cells, and the blood was then run through the microchip device to capture the labelled cells. After capture, the cells were stained with fluorescent labelled anti-cytokeratin, DAPI and anti-CD45. Subsequent immunofluorescence images were taken for the captured cells, followed by comprehensive computer aided analysis based on fluorescence intensities and cell morphology. Rare cancer cells (from ∼1000 cells down to ∼5 cells per mL) with very low tumor cell to blood cell ratios (about 1 : 107 to 109, including red blood cells) were successfully detected. Cancer cell capture rates of 90% and 86% were demonstrated for COLO205 and SKBR3 cells, respectively.

1 March 2006 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
KNKentaro Noda
Kentaro Noda
KHKazunori Hoshino
Kazunori Hoshino
KMKiyoshi Matsumoto
Kiyoshi Matsumoto
ISIsao Shimoyama
Isao Shimoyama

9 September 2013 in ACS Nano
Verified
Journal Article
Closed access
CWChun-Hsien Wu
Chun-Hsien Wu
YHYu-Yen Huang
Yu-Yen Huang
PCPeng Chen
Peng Chen
KHKazunori Hoshino
Kazunori Hoshino
HLHuaying Liu
Huaying Liu
KSKonstantin V. Sokolov
Konstantin V. Sokolov

22 November 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DJDevina Jaiswal
Devina Jaiswal
NCNorah Cowley
Norah Cowley
ZBZichao Bian
Zichao Bian
GZGuoan Zheng
Guoan Zheng
KCKevin P. Claffey
Kevin P. Claffey
KHKazunori Hoshino
Kazunori Hoshino
We describe a novel mechanical characterization method that has directly measured the stiffness of cancer spheroids for the first time to our knowledge. Stiffness is known to be a key parameter that characterizes cancerous and normal cells. Atomic force microscopy or optical tweezers have been typically used for characterization of single cells with the measurable forces ranging from sub pN to a few hundred nN, which are not suitable for measurement of larger 3D cellular structures such as spheroids, whose mechanical characteristics have not been fully studied. Here, we developed microtweezers that measure forces from sub hundred nN to mN. The wide force range was achieved by the use of replaceable cantilevers fabricated from SU8, and brass. The chopstick-like motion of the two cantilevers facilitates easy handling of samples and microscopic observation for mechanical characterization. The cantilever bending was optically tracked to find the applied force and sample stiffness. The efficacy of the method was demonstrated through stiffness measurement of agarose pillars with known concentrations. Following the initial system evaluation with agarose, two cancerous (T47D and BT474) and one normal epithelial (MCF 10A) breast cell lines were used to conduct multi-cellular spheroid measurements to find Young’s moduli of 230, 420 and 1250 Pa for BT474, T47D, and MCF 10A, respectively. The results showed that BT474 and T47D spheroids are six and three times softer than epithelial MCF10A spheroids, respectively. Our method successfully characterized samples with wide range of Young’s modulus including agarose (25–100 kPa), spheroids of cancerous and non-malignant cells (190–200 μm, 230–1250 Pa) and collagenase-treated spheroids (215 μm, 130 Pa).

2 December 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
PCPeng Chen
Peng Chen
YHYu-Yen Huang
Yu-Yen Huang
KHKazunori Hoshino
Kazunori Hoshino
XZXiaojing Zhang
Xiaojing Zhang
We review the rare cancer cell sorting technologies, with a focus on multiscale immunomagnetic approaches. Starting from the conventional magnetic activated cell sorting system, we derive the scaling laws of immunomagnetic assay and justify the recent trend of using downscaled systems for CTC studies. Furthermore, we introduce recent work on combining the immunomagnetic assay with microfluidic technology for enhanced separation. We summarize different types of in-channel micro-magnetic structures that can further increase the local magnetic field without lowering the system throughput. Related design concepts, principles, and microfabrication techniques are presented and evaluated.