Kentaro Noda

Kentaro Noda

Auto-generated profile, based on publicly available information

Kentaro Noda

The University of Tokyo, Japan

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2006 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
KNKentaro Noda
Kentaro Noda
KHKazunori Hoshino
Kazunori Hoshino
KMKiyoshi Matsumoto
Kiyoshi Matsumoto
ISIsao Shimoyama
Isao Shimoyama

1 August 2014 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
KNKentaro Noda
Kentaro Noda
KMKiyoshi Matsumoto
Kiyoshi Matsumoto
ISIsao Shimoyama
Isao Shimoyama

18 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
TOTaiyu Okatani
Taiyu Okatani
HTHidetoshi Takahashi
Hidetoshi Takahashi
KNKentaro Noda
Kentaro Noda
TTTomoyuki Takahata
Tomoyuki Takahata
KMKiyoshi Matsumoto
Kiyoshi Matsumoto
ISIsao Shimoyama
Isao Shimoyama
This paper reports on a tactile sensor using piezoresistive beams for detection of the coefficient of static friction merely by pressing the sensor against an object. The sensor chip is composed of three pairs of piezoresistive beams arranged in parallel and embedded in an elastomer; this sensor is able to measure the vertical and lateral strains of the elastomer. The coefficient of static friction is estimated from the ratio of the fractional resistance changes corresponding to the sensing elements of vertical and lateral strains when the sensor is in contact with an object surface. We applied a normal force on the sensor surface through objects with coefficients of static friction ranging from 0.2 to 1.1. The fractional resistance changes corresponding to vertical and lateral strains were proportional to the applied force. Furthermore, the relationship between these responses changed according to the coefficients of static friction. The experimental result indicated the proposed sensor could determine the coefficient of static friction before a global slip occurs.

1 January 2012
Verified
Conference Paper
Closed access
SWS. Wattanasarn
S. Wattanasarn
KNK. Noda
K. Noda
KMK. Matsumoto
K. Matsumoto
ISIsao Shimoyama
Isao Shimoyama
A 3D flexible tactile sensor has been fabricated based on the principle of electromagnetic induction. A force applied to the proposed elastomer-based sensor causes mechanical deformations in the sensor structure, which subsequently alter the induced voltage of each coil couple embedded in the sensor. The magnitude and direction of forces can be calculated with that induced voltages data through generalized transfer functions. A 3-axis force sensing capability and repeatability with an average standard deviation of 0.109 mV are achieved with a simple fabrication process and low cost. The proposed sensor could satisfy demands of tactile sensing in various robotic applications as well as 3D force measurement works.

1 May 2010
Verified
Conference Paper
Closed access
KNK. Noda
K. Noda
EIEiji Iwase
Eiji Iwase
KMK. Matsumoto
K. Matsumoto
ISIsao Shimoyama
Isao Shimoyama
In this paper, we propose a stretchable tactile sensor composed of a pair of silicone rubber channels filled with electro conductive liquid. When a force was applied to this channel, its length and cross-sectional area deforms. By measuring the resistance change of the electro conductive liquid in the channel, its deformation can be measured. The proposed tactile sensor is composed of two parallel channel filled with electro conductive liquid, therefore, by comparing the resistance changes of each channel to the deformation, only the contacting force can be measured independently. Since a liquid is used for the sensing material, the proposed liquid tactile sensor can be easily attached to movable portions as the joints of robots. In the paper, we measured the sensing characteristics of the liquid tactile sensor to the stretch, bend, and contact force. Finally, the efficiency of the sensor was demonstrated by measuring the contact force from 0 to 3.0N by attaching the 20% stretched liquid tactile sensor to curved surfaces with 0.05mm-1 in curvature.

12 June 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
YSYoshiki Saito
Yoshiki Saito
YYYosuke Yamamoto
Yosuke Yamamoto
TKTetsuo Kan
Tetsuo Kan
TTTakuya Tsukagoshi
Takuya Tsukagoshi
KNKentaro Noda
Kentaro Noda
ISIsao Shimoyama
Isao Shimoyama
A current detection surface plasmon resonance (SPR) sensor with an Au grating on an n-Si wafer was proposed. SPR excitation light is illuminated from the backside of the device and diffracted by the grating. Since the diffraction provides matching conditions, SPR can be coupled to the Au/analyte interface. Since the coupled SPR excites free electrons on the Au surface, the SPR can be detected as a current signal by a Schottky barrier diode formed on the Au/n-Si interface. The obtained angular current spectrum showed clear agreement with SPR coupling theory, thereby confirming that the sample on the Au surface can be electrically detected using the proposed sensor.