Eckhard Schleicher

Dr. Eckhard Schleicher

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2015 in International Journal of Multiphase Flow
Verified
Journal Article
Closed access
MPMazdak Parsi
Mazdak Parsi
RVRonald E. Vieira
Ronald E. Vieira
CTCarlos F. Torres
Carlos F. Torres
NKNetaji R. Kesana
Netaji R. Kesana
BMBrenton S. McLaury
Brenton S. McLaury
UHUwe Hampel
Uwe Hampel

16 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
UHUwe Hampel
Uwe Hampel
Laurent BaboutLaurent Babout
Laurent Babout
Robert BanasiakRobert Banasiak
Robert Banasiak
ESEckhard Schleicher
Eckhard Schleicher
MSManuchehr Soleimani
Manuchehr Soleimani
Alexander PennAlexander Penn
Alexander Penn
With the ongoing digitalization of industry, imaging sensors are becoming increasingly important for industrial process control. In addition to direct imaging techniques such as those provided by video or infrared cameras, tomographic sensors are of interest in the process industry where harsh process conditions and opaque fluids require non-intrusive and non-optical sensing techniques. Because most tomographic sensors rely on complex and often time-multiplexed excitation and measurement schemes and require computationally intensive image reconstruction, their application in the control of highly dynamic processes is often hindered. This article provides an overview of the current state of the art in fast process tomography and its potential for use in industry.

10 September 2014 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
RVRonald E. Vieira
Ronald E. Vieira
NKNetaji R. Kesana
Netaji R. Kesana
CTCarlos F. Torres
Carlos F. Torres
BMBrenton S. McLaury
Brenton S. McLaury
SSSiamack A. Shirazi
Siamack A. Shirazi
UHUwe Hampel
Uwe Hampel
Stratified and annular gas–liquid flow patterns are commonly encountered in many industrial applications, such as oil and gas transportation pipelines, heat exchangers, and process equipment. The measurement and visualization of two-phase flow characteristics are of great importance as two-phase flows persist in many fluids engineering applications. A wire-mesh sensor (WMS) technique based on conductance measurements has been applied to investigate two-phase horizontal pipe flow. The horizontal flow test section consisting of a 76.2 mm ID pipe, 18 m long was employed to generate stratified and annular flow conditions. Two 16 × 16 wire configuration sensors, installed 17 m from the inlet of the test section, are used to determine the void fraction within the cross section of the pipe and determine interface velocities between the gas and liquid. These physical flow parameters were extracted using signal processing and cross-correlation techniques. In this work, the principle of WMS and the methodology of flow parameter extraction are described. From the obtained raw data time series of void fraction, cross-sectional mean void fraction, time averaged void fraction profiles, interfacial structures, and velocities of the periodic structures are determined for different liquid and gas superficial velocities that ranged from 0.03 m/s to 0.2 m/s and from 9 m/s to 34 m/s, respectively. The effects of liquid viscosity on the measured parameters have also been investigated using three different viscosities.

19 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MAMartin Arlit
Martin Arlit
UHUwe Hampel
Uwe Hampel
ESEckhard Schleicher
Eckhard Schleicher
A novel thermal anemometry grid sensor was developed for the simultaneous measurement of cross-sectional temperature and axial velocity distribution in a fluid flow. The sensor consists of a set of platinum resistors arranged in a regular grid. Each platinum resistor allows the simultaneous measurement of fluid temperature via electrical resistance and flow velocity via constant voltage thermal anemometry. Cross-sectional measurement was enabled by applying a special multiplexing-excitation scheme. In this paper, we present the design and characterization of a prototypical sensor for measurements in a range of very low velocities.

11 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PWPhilipp Wiedemann
Philipp Wiedemann
FDFelipe de Assis Dias
Felipe de Assis Dias
ESEckhard Schleicher
Eckhard Schleicher
UHUwe Hampel
Uwe Hampel
Wire-mesh sensors are well-established scientific instruments for measuring the spatio-temporal phase distribution of two-phase flows based on different electrical conductivities of the phases. Presently, these instruments are also applied in industrial processes and need to cope with dynamic operating conditions increasingly. However, since the quantification of phase fractions is achieved by normalizing signals with respect to a separately recorded reference measurement, the results are sensitive to temperature differences in any application. Therefore, the present study aims at proposing a method to compensate temperature effects in the data processing procedure. Firstly, a general approach is theoretically derived from the underlying measurement principle and compensation procedures for the electrical conductivity from literature models. Additionally, a novel semi-empirical model is developed on the basis of electrochemical fundamentals. Experimental investigations are performed using a single-phase water loop with adjustable fluid temperature in order to verify the theoretical approach for wire-mesh sensor applications and to compare the different compensation models by means of real data. Finally, the preferred model is used to demonstrate the effect of temperature compensation with selected sets of experimental two-phase data from a previous study. The results are discussed in detail and show that temperature effects need to be handled carefully—not merely in industrial applications, but particularly in laboratory experiments.

7 January 2008 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ESEckhard Schleicher
Eckhard Schleicher
MSMarco Jose Da Silva
Marco Jose Da Silva
UHUwe Hampel
Uwe Hampel
We introduce a novel combined-temperature-and-conductivity needle probe measuring system for local void fraction measurements in multiphase-flow experiments. The system is able to deal with direct sheathed microthermocouples as well as open thermocouples. It consists of a thermoneedle probe connected to a special electronic circuit using an ac measuring technique for the conductivity measurements and a high-gain instrumentation amplifier with very high common-mode rejection for the amplification of the Seebeck voltage generated by the microthermocouple. After system buildup and calibration, the system has been tested in different experiments. In a dropping experiment, the time constant of the temperature measurement of the needle probe system was determined as 3.6 ms. Additionally, steam-water and gas-steam-water flow experiments have been carried out to demonstrate the system performance.