Three-phase gas-oil-water flow is an important type of flow present in petroleum extraction and processing. This paper reports a novel threshold-based method to visualize and estimate the cross-sectional phase fraction of gas-oil-water mixtures. A $16\times 16$ dual-modality wire-mesh sensor (WMS) was employed to simultaneously determine the conductive and capacitive components of the impedance of fluid. Then, both electrical parameters are used to classify readings of WMS into either pure substance (gas, oil or water) or two-phase oil-water mixtures (foam is neglected in this work). Since the wire-mesh sensor interrogates small regions of the flow domain, we assume that the three-phase mixture can be segmented according to the spatial sensor resolution (typically 2–3 mm). Hence, the proposed method simplifies a complex three-phase system in several segments of single or two-phase mixtures. In addition to flow visualization, the novel approach can also be applied to estimate quantitative volume fractions of flowing gas-oil-water mixtures. The proposed method was tested in a horizontal air-oil-water flow loop in different flow conditions. Experimental results suggest that the threshold-based method is able to capture transient three-phase flows with high temporal and spatial resolution even in the presence of water-oil dispersion regardless of the continuous phase.
Wire-mesh sensors are well-established scientific instruments for measuring the spatio-temporal phase distribution of two-phase flows based on different electrical conductivities of the phases. Presently, these instruments are also applied in industrial processes and need to cope with dynamic operating conditions increasingly. However, since the quantification of phase fractions is achieved by normalizing signals with respect to a separately recorded reference measurement, the results are sensitive to temperature differences in any application. Therefore, the present study aims at proposing a method to compensate temperature effects in the data processing procedure. Firstly, a general approach is theoretically derived from the underlying measurement principle and compensation procedures for the electrical conductivity from literature models. Additionally, a novel semi-empirical model is developed on the basis of electrochemical fundamentals. Experimental investigations are performed using a single-phase water loop with adjustable fluid temperature in order to verify the theoretical approach for wire-mesh sensor applications and to compare the different compensation models by means of real data. Finally, the preferred model is used to demonstrate the effect of temperature compensation with selected sets of experimental two-phase data from a previous study. The results are discussed in detail and show that temperature effects need to be handled carefully—not merely in industrial applications, but particularly in laboratory experiments.
10 February 2021 in IEEE Transactions on Instrumentation and Measurement
A wire-mesh sensor (WMS) is a widely used instrument to visualize and estimate derived parameters of multiphase flows, e.g., gas void fraction or liquid hold-up. The spatial resolution of obtained flow images is associated with the number of crossing points formed by the transmitter and receiver wires of a given sensor. This may be a limitation for applications that require high spatial resolution since WMS is an intrusive device and the increase of electrodes may increase pressure drop and deform/fragment bubbles. In order to minimize such undesirable effects and maximize the sensor resolution, we employed a reconstruction algorithm based on the minimum mean-square error (MMSE) estimator to increase image resolution of WMS with fewer wires than commonly reported in the literature, i.e., here, we apply $8\times 8$ , $6\times 6$ , $4\times 4$ , and $2\times 2$ sensors for 1-in pipe. Since standard regularization approaches may provide incorrect solutions for such configurations, a new methodology to obtain the prior model is presented. In our approach, the prior is assumed as a multivariate Gaussian model, which is extracted from experimental flow data of a $16\times 16$ WMS (the most common resolution for 1-in pipe). Finally, the sensitivity matrix obtained by electric field simulation and the experimental prior model is incorporated into the MMSE algorithm to restore experimental flow data of the low-resolution sensors. The experiments were performed in a flow loop operating at slug flow. The experimental results suggest that the MMSE estimator combined with the experimental prior model has a high potential not only to improve image resolution but also to correct the average void fraction estimation.
Real-time monitoring of gas-liquid pipe flow is highly demanded in industrial processes in the chemical and power engineering sectors. Therefore, the present contribution describes the novel design of a robust wire-mesh sensor with an integrated data processing unit. The developed device features a sensor body for industrial conditions of up to 400 °C and 135 bar as well as real-time processing of measured data, including phase fraction calculation, temperature compensation and flow pattern identification. Furthermore, user interfaces are included via a display and 4…20 mA connectivity for the integration into industrial process control systems. In the second part of the contribution, we describe the experimental verification of the main functionalities of the developed system. Firstly, the calculation of cross-sectionally averaged phase fractions along with temperature compensation was tested. Considering temperature drifts of up to 55 K, an average deviation of 3.9% across the full range of the phase fraction was found by comparison against image references from camera recordings. Secondly, the automatic flow pattern identification was tested in an air–water two-phase flow loop. The results reveal reasonable agreement with well-established flow pattern maps for both horizontal and vertical pipe orientations. The present results indicate that all prerequisites for an application in industrial environments in the near future are fulfilled.
We reviewed the electronic principles and design of the wire-mesh sensor with respect to inherent energy losses. From the analysis we derived a new circuit design with an optimized amplifier circuit and extended the sensor by an extra transmitter electrode embedded into the dielectric construction material. The latter allows an inherent determination of the energy losses that cannot be suppressed by circuit optimization only. Experimental analysis showed that we achieve an improvement in measurement accuracy with respect to the local and average phase fractions. Deviations in a single crossing point are reduced from more than down to less than and deviations in the average phase fraction are reduced from more than down to less than .
30 April 2025 in Flow Measurement and Instrumentation