Brine with a high magnesium-to-lithium ratio was separated by electrodialysis equipped with a monovalent cation exchange membrane under differing operational parameters. The ionic concentration variations, separation coefficients, lithium recovery ratio, permselectivity coefficient, and Li+ flux were analyzed to evaluate the effect of the initial Li+/Mg2+ mass concentration ratio, applied voltage, and initial volume ratio between the dilute and concentrated compartments on the separation performance of magnesium and lithium. The results showed that the increase in initial Li+/Mg2+ concentration ratio significantly increased the separation coefficient, lithium recovery ratio, and Li+ flux, demonstrating an improvement in the separation performance since the Li+ migration was accelerated when less Mg2+ competed with Li+. As the applied voltage increased from 10 V to 15 V, the separation coefficient increased, and the lithium recovery ratio and Li+ flux increased within 60 min; however, as the applied voltage increased to 20 V, the separation coefficient, the lithium recovery ratio, and the Li+ flux did not increase, which indicated that an increase in the applied voltage within the limits would contribute to the separation performance. The increase in the initial volume ratio between the dilute and concentrated compartments decreased the separation coefficient and lithium recovery ratio, indicating that the separation performance had declined.
1 August 2025 in Journal of Physics: Conference Series
Stainless steel, known for its excellent corrosion resistance, is widely used in various fields such as energy, chemical processing, and marine engineering. However, under certain environmental conditions—especially high temperature and high chloride environments—intergranular corrosion (IGC) remains one of the primary causes of stainless steel failure, posing serious safety risks in critical applications. This paper reviews recent advances in the study of IGC in stainless steels. It first introduces classical mechanisms such as the chromium depletion effect, and then discusses newly proposed mechanisms including sigma (σ) phase precipitation and impurity element segregation. Subsequently, the article summarizes detection methods for IGC, with a focus on techniques such as electrochemical potentiokinetic reactivation (EPR) and localized electrochemical methods (SVET/LEIS), which offer improved precision and broader applicability. Finally, strategies for enhancing IGC resistance are discussed, including alloy composition optimization, heat treatment processes, and data-driven service life prediction models. Future research directions include the development of innovative testing technologies and advanced corrosion-resistant stainless steel design to address challenges under complex service conditions.
A polyamine water treatment agent was prepared with the film-forming amine (N-oleyl-1,3-propylenediamine) and the neutralizing amine (cyclohexanamine) under optimal conditions. The copper sulfate liquid drop experiment showed that a protective film was formed by the polyamine water treatment agent on carbon steel. The analyses of the polarization curve and electrochemical impedance spectroscopy of carbon steel indicated that the polyamine water treatment agent exhibited geometric effects, which could inhibit both anode and cathode reactions of carbon steel, and the corrosion inhibition effect of the polyamine water treatment agent showed an extreme-concentration phenomenon. A metal corrosion experiment in a simulated boiler steam–water system indicated that the polyamine water treatment agent mitigated the corrosion of carbon steel at different temperatures, and the corrosion inhibition rates of the polyamine water treatment agent in liquid and gas environments at 150 °C were 53.84% and 67.43%, respectively, better than that at 350 °C. SEM-EDS characterization indicated that the formation of the corrosion product, iron oxide, on the carbon steel was reduced with the addition of the polyamine water treatment agent in the simulated boiler steam–water system.
A commercial anion-exchange membrane was modified via the electrodeposition of different water-soluble polymers to study the effects of surface modification on electrodialysis performance. X-ray photoelectron spectroscopy and attenuated total reflectance Fourier transform infrared spectroscopy analyses showed that the different polymers were successfully electrodeposited on the membrane surface. The surface morphology and electrical resistance of the modified AEMs were almost unchanged. Contact angle and zeta potential measurements indicated differences in the surface hydrophilicity and surface charge density of the modified AEMs. The electrodialysis performance of the pristine AEM declined significantly in the presence of the foulant. In contrast, the electrodialysis performance of the AEMs modified with poly (vinylsulfonic acid, sodium salt) showed almost no decline and exhibited the best antifouling property in the presence of the foulant, followed by those modified with poly (sodium acrylate) and poly (vinyl alcohol). The results indicated that an increase in surface negative charge density and surface hydrophilicity increased the resistance of the modified AEMs to the foulant and improved their electrodialysis performance.