In this paper, a novel method for electric field intensity and magnetic induction estimation in the vicinity of the high voltage overhead transmission lines is proposed. The proposed method is based on two fully connected feed-forward neural networks to independently estimate electric field intensity and magnetic induction. The artificial neural networks are trained using the scaled conjugate gradient algorithm. Training datasets corresponds to different overhead transmission line configurations that are generated using an algorithm that is especially developed for this purpose. The target values for the electric field intensity and magnetic induction datasets are calculated using the charge simulation method and Biot-Savart law based method, respectively. This data is generated for fixed applied voltage and current intensity values. In instances when the applied voltage and current intensity values differ from those used in the artificial neural network training, the electric field intensity and magnetic induction results are appropriately scaled. In order to verify the validity of the proposed method, a comparative analysis of the proposed method with the charge simulation method for electric field intensity calculation and Biot-Savart law-based method for magnetic induction calculation is presented. Furthermore, the results of the proposed method are compared to measurement results obtained in the vicinity of two 400 kV transmission lines. The performance analysis results showed that proposed method can produce accurate electric field intensity and magnetic induction estimation results for different overhead transmission line configurations.
3 June 2020 in IEEE Transactions on Power Delivery
This study interprets results of multiparametric measurements obtained on a pipeline experiencing dynamic stray currents caused by DC train traction. Measurements included three 24 h recordings of pipe-to-soil and rail-to-soil potentials, pipe-to-rail voltages and drainage currents in cases without mitigation measures, with polarized drainage and with forced drainage. Time domain analysis included construction of frequency diagrams and linear correlation between pipe-to-soil potentials and pipe-to-rail voltages. Wavelet space analysis pinpoints time intervals with harmful stray current periods within them and resolves between the dominant potential shifts due to the nearby passing trains and distant trains in the transport network.
In this paper, a novel method for the magnetic flux density estimation in the vicinity of multi-circuit overhead transmission lines is proposed. The proposed method is based on a fully connected feed-forward artificial neural network model that is trained to estimate the magnetic flux density vector components for a range of single-circuit overhead transmission lines. The proposed algorithm is able to simplify estimation process in instances when there are two or more geometrically identical circuits present in the multi-circuit overhead transmission line. In such instances, artificial neural network model is employed to estimate the magnetic flux density distribution over a considered lateral profile for only one of such circuits. The magnetic flux density estimates of the other geometrically identical circuits are derived from these results. The proposed methodology defines the resultant magnetic flux density for the multi-circuit overhead transmission line in terms of the contributions made by individual circuits. The application of the proposed magnetic flux density estimation method is demonstrated on several multi-circuit configurations of overhead transmission lines. The performance of the proposed method is compared with the Biot-Savart law based method calculation results as well as with field measurement results.
The use of renewable energy sources increases the energy self-sustainability of cities, enabling citizens to reduce energy costs, which results in an increase in their standard of living. However, solar energy penetration in Bosnia and Herzegovina, and its capital Sarajevo, is not in line with the possibilities. Furthermore, the Sarajevo Canton is extremely polluted during the winter months because of the use of unacceptable heating fuel. The aim of this paper is to introduce photovoltaic power systems use in heating electrification system. In this paper AQI is calculated based on historical data and the hybrid model EMD-SARIMA for air pollution and a solar production forecast is presented. The methodology was tested in the Sarajevo Canton, taking into account 35,000 households. In order to ensure clean air, renewable electric energy use for household heating should be implemented. The widespread use of inefficient individual heating systems characterized by inefficient and expensive use of firewood and the use of coal in individual furnaces in populated areas are the main problems of internal and urban air pollution in Sarajevo Canton. In order to reduce energy poverty in Sarajevo Canton, the use of a floating photovoltaic power plant located on Lake Jablanica with a capacity of 30 MW and the solar prosumers with capacity of 115 MW to provide the 196 GWh necessary for heating electrification of 35,000 households is implemented in this paper. Finally, based on correlation between AQI forecast and solar production it was calculated that the values of the AQI, considering the application of solar energy during 150 days (five months) in one heating season, have significantly decreased. Also renewable energy sources have a very important role in reducing carbon dioxide (CO2) emissions into the atmosphere and reducing urban pollution. With this approach, households would be heated by renewable electricity, which would make Sarajevo a cleaner, smarter city.
Paper presents a calculation of the electric field distribution around the 400 kV transmission lines in power system of Bosnia and Herzegovina (B&H). Method of equivalent charges was used for the calculation of the electric field at arbitrary points in the vicinity of high-voltage transmission lines. Transmission lines with standard tower's dimensions, as well as lines with reduced (compact) tower's dimensions were considered. Comparisons between calculated and measured results of electric field values around the transmission line with the standard dimensions of the tower on 400 kV line Sarajevo 10 - Sarajevo 20 was performed.