In this paper using Artificial Neural Network (ANN) are presented forecasting results of PM10 concentrations for the city of Sarajevo. Input data of the proposed model are meteorological variables (wind speed, humidity, temperature and pressure) and pollution variable (PM10 concentration) recorded in the Federal Institute for Hydrometeorology from 2010 to 2013. The proposed model is tested on the several cases and the results are satisfactory. The results of the forecasting show the different effects that certain meteorological parameters have on the temporal prediction of concentrations of PM10. It can also be concluded that ANN approach is very useful in terms of the time series forecast the concentrations of PM10 particles with good forecasting results. Also, it is presented the idea of a unified system for air quality improvement, which involves a variety of systemic measures in the areas affected by an increase of PM10 concentrations.
In this paper, a novel method for the magnetic flux density estimation in the vicinity of multi-circuit overhead transmission lines is proposed. The proposed method is based on a fully connected feed-forward artificial neural network model that is trained to estimate the magnetic flux density vector components for a range of single-circuit overhead transmission lines. The proposed algorithm is able to simplify estimation process in instances when there are two or more geometrically identical circuits present in the multi-circuit overhead transmission line. In such instances, artificial neural network model is employed to estimate the magnetic flux density distribution over a considered lateral profile for only one of such circuits. The magnetic flux density estimates of the other geometrically identical circuits are derived from these results. The proposed methodology defines the resultant magnetic flux density for the multi-circuit overhead transmission line in terms of the contributions made by individual circuits. The application of the proposed magnetic flux density estimation method is demonstrated on several multi-circuit configurations of overhead transmission lines. The performance of the proposed method is compared with the Biot-Savart law based method calculation results as well as with field measurement results.
The use of renewable energy sources increases the energy self-sustainability of cities, enabling citizens to reduce energy costs, which results in an increase in their standard of living. However, solar energy penetration in Bosnia and Herzegovina, and its capital Sarajevo, is not in line with the possibilities. Furthermore, the Sarajevo Canton is extremely polluted during the winter months because of the use of unacceptable heating fuel. The aim of this paper is to introduce photovoltaic power systems use in heating electrification system. In this paper AQI is calculated based on historical data and the hybrid model EMD-SARIMA for air pollution and a solar production forecast is presented. The methodology was tested in the Sarajevo Canton, taking into account 35,000 households. In order to ensure clean air, renewable electric energy use for household heating should be implemented. The widespread use of inefficient individual heating systems characterized by inefficient and expensive use of firewood and the use of coal in individual furnaces in populated areas are the main problems of internal and urban air pollution in Sarajevo Canton. In order to reduce energy poverty in Sarajevo Canton, the use of a floating photovoltaic power plant located on Lake Jablanica with a capacity of 30 MW and the solar prosumers with capacity of 115 MW to provide the 196 GWh necessary for heating electrification of 35,000 households is implemented in this paper. Finally, based on correlation between AQI forecast and solar production it was calculated that the values of the AQI, considering the application of solar energy during 150 days (five months) in one heating season, have significantly decreased. Also renewable energy sources have a very important role in reducing carbon dioxide (CO2) emissions into the atmosphere and reducing urban pollution. With this approach, households would be heated by renewable electricity, which would make Sarajevo a cleaner, smarter city.
The city of Sarajevo as the capital and the largest administrative and economic center in Bosnia and Herzegovina represents one of the most polluted cities in Europe in terms of the concentration of PM10 (particulate matter 10). Scientific and professional communities have particularly been focused on identifying the causes of this situation, and on the introduction of the system of measures to reduce PM10 values to below the limit values. This paper analyzes the impact of meteorological variables (wind speed, humidity, temperature and pressure) to the concentration of PM10 in the city of Sarajevo by using the Wavelet Coherence approach (WTC). Available data indicate actual values recorded in the Federal Institute for Hydrometeorology in 2012. The results of the analysis show the different effects that certain meteorological parameters have on the concentrations of PM10 particles in a time period of one year. It can also be concluded that this approach is very useful in terms of the practical interpretation of available data and it offers a clearer picture of the impact of meteorological conditions on the concentrations of PM10 particles.
The decrease in overall inertia in power systems due to the shift from synchronous generator production to renewable energy sources (RESs) presents a significant challenge. This transition affects the system’s stable frequency response, making it highly sensitive to imbalances between production and consumption, particularly during large disturbances. To address this issue, this paper introduces a novel approach using Multivariate Empirical Mode Decomposition (MEMD) for the accurate estimation of power system inertia. This approach involves applying MEMD, a complex signal processing technique, to power system frequency signals. The study utilizes PMU (Phasor Measurement Unit) data and simulated disturbances in the IEEE 39 bus test system to conduct this analysis. MEMD offers substantial advantages in analyzing multivariate data and frequency signals during disturbances, providing accurate estimations of system inertia. This approach enhances the understanding of power system dynamics in the context of renewable energy integration. However, the complexity of this methodology and the requirement for precise data collection are challenges that need to be addressed. The results from this approach show high accuracy in estimating the rate of change of frequency (RoCoF) and system inertia, with minimal deviation from actual values. The findings highlight the significant impact of renewable energy integration on system inertia and emphasize the necessity of accurate inertia estimation in modern power systems.
This paper considers the method for the calculation of magnetic flux density in the vicinity of overhead distribution lines which takes into account the higher current harmonics. This method is based on the Biot–Savart law and the complex image method. The considered method calculates the values of the magnetic flux density for each harmonic component of the current separately at all points of interest (usually lateral profile). In this way, it is possible to determine the contributions of individual harmonic components of the current intensity to the total value of magnetic flux density. Based on the contributions of individual harmonic components, the total (resultant) value of the magnetic flux density at points of interest is determined. Validation of the computational method is carried out by comparison of the results obtained by the considered calculation method with measurement results. Furthermore, the application of the calculation method was demonstrated by calculating magnetic flux density harmonics in the vicinity of two overhead distribution lines of typical phase conductor arrangements.