Emir Turajlic

Prof. Emir Turajlic

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2021 in IEEE Access
Verified
Journal Article
Open access
AAAjdin Alihodzic
Ajdin Alihodzic
AMAdnan Mujezinovic
Adnan Mujezinovic
ETEmir Turajlic
Emir Turajlic
In this paper, a novel method for electric field intensity and magnetic induction estimation in the vicinity of the high voltage overhead transmission lines is proposed. The proposed method is based on two fully connected feed-forward neural networks to independently estimate electric field intensity and magnetic induction. The artificial neural networks are trained using the scaled conjugate gradient algorithm. Training datasets corresponds to different overhead transmission line configurations that are generated using an algorithm that is especially developed for this purpose. The target values for the electric field intensity and magnetic induction datasets are calculated using the charge simulation method and Biot-Savart law based method, respectively. This data is generated for fixed applied voltage and current intensity values. In instances when the applied voltage and current intensity values differ from those used in the artificial neural network training, the electric field intensity and magnetic induction results are appropriately scaled. In order to verify the validity of the proposed method, a comparative analysis of the proposed method with the charge simulation method for electric field intensity calculation and Biot-Savart law-based method for magnetic induction calculation is presented. Furthermore, the results of the proposed method are compared to measurement results obtained in the vicinity of two 400 kV transmission lines. The performance analysis results showed that proposed method can produce accurate electric field intensity and magnetic induction estimation results for different overhead transmission line configurations.


20 November 2018 in IEEE Access
Verified
Journal Article
Open access
ETEmir Turajlic
Emir Turajlic
Noise level estimation is a challenging area of digital image processing with a variety of applications including image enhancement, image segmentation and feature extraction. In this paper, an adaptive estimation of additive white Gaussian noise level based on the singular value decomposition (SVD) of images is proposed. The proposed algorithm aims to improve the performance of noise level estimation in the SVD domain at low noise levels. An initial noise level estimate is used to adjust the parameters of the algorithm in order to increase the accuracy of noise level estimation. The proposed algorithm exhibits the ability to adapt the number of considered singular values and to accordingly adjust the slope of a linear function that describes how the average value of the singular value tail varies with noise levels. Although, for each image, the proposed algorithm performs the noise level estimation twice in two distinct stages, the singular value decompositions are only performed in the first stage of the algorithm. The experimental results demonstrate that the proposed algorithm improves the noise level estimation at low noise levels without a significant increase in computational complexity. At noise level σ=15, the improvements in the mean square level are about 39% at the expense of slightly higher additional computational time.

1 February 2019 in Electronics
Verified
Journal Article
Open access
PDF file
ETEmir Turajlic
Emir Turajlic
ABAlen Begović
Alen Begović
NŠNamir Škaljo
Namir Škaljo
The blind additive white Gaussian noise level estimation is an important and a challenging area of digital image processing with numerous applications including image denoising and image segmentation. In this paper, a novel block-based noise level estimation algorithm is proposed. The algorithm relies on the artificial neural network to perform a complex image patch analysis in the singular value decomposition (SVD) domain and to evaluate noise level estimates. The algorithm exhibits the capacity to adjust the effective singular value tail length with respect to the observed noise levels. The results of comparative analysis show that the proposed ANN-based algorithm outperforms the alternative single stage block-based noise level estimating algorithm in the SVD domain in terms of mean square error (MSE) and average error for all considered choices of block size. The most significant improvements in MSE levels are obtained at low noise levels. For some test images, such as “Car” and “Girlface”, at σ = 1 , these improvements can be as high as 99% and 98.5%, respectively. In addition, the proposed algorithm eliminates the error-prone manual parameter fine-tuning and automates the entire noise level estimation process.

1 September 2022 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
Verified
Journal Article
Open access
AAAjdin Alihodzic
Ajdin Alihodzic
AMAdnan Mujezinovic
Adnan Mujezinovic
ETEmir Turajlic
Emir Turajlic
MDMaja Muftić Dedović
Maja Muftić Dedović

9 February 2022 in Electronics
Verified
Journal Article
Open access
PDF file
AMAdnan Mujezinovic
Adnan Mujezinovic
ETEmir Turajlic
Emir Turajlic
AAAjdin Alihodzic
Ajdin Alihodzic
MDMaja Muftić Dedović
Maja Muftić Dedović
NDNedis Dautbasic
Nedis Dautbasic
This paper considers the method for the calculation of magnetic flux density in the vicinity of overhead distribution lines which takes into account the higher current harmonics. This method is based on the Biot–Savart law and the complex image method. The considered method calculates the values of the magnetic flux density for each harmonic component of the current separately at all points of interest (usually lateral profile). In this way, it is possible to determine the contributions of individual harmonic components of the current intensity to the total value of magnetic flux density. Based on the contributions of individual harmonic components, the total (resultant) value of the magnetic flux density at points of interest is determined. Validation of the computational method is carried out by comparison of the results obtained by the considered calculation method with measurement results. Furthermore, the application of the calculation method was demonstrated by calculating magnetic flux density harmonics in the vicinity of two overhead distribution lines of typical phase conductor arrangements.