Temperature reflects the balance between production and dissipate of heat. Flexible temperature sensors are primary sensors used for temperature monitoring. To obtain real-time and accurate information of temperature, different flexible temperature sensors are developed according to the principle of flexible resistance temperature detector (FRTC), flexible thermocouple, flexible thermistor and flexible thermochromic, showing great potential in energy conversion and storage. In order to obtain high integration and multifunction, various flexible temperature sensors are studied and optimized, including active-matrix flexible temperature sensor, self-powered flexible temperature sensor, self-healing flexible temperature sensor and self-cleaning flexible temperature sensor. This review focuses on the structure, material, fabrication and performance of flexible temperature sensors. Also, some typical applications of flexible temperature sensors are discussed and summarized.
Neural microelectrode is the important bridge of information exchange between the human body and machines. By recording and transmitting nerve signals with electrodes, people can control the external machines. At the same time, using electrodes to electrically stimulate nerve tissue, people with long-term brain diseases will be safely and reliably treated. Young’s modulus of the traditional rigid electrode probe is not matched well with that of biological tissue, and tissue immune rejection is easy to generate, resulting in the electrode not being able to achieve long-term safety and reliable working. In recent years, the choice of flexible materials and design of electrode structures can achieve modulus matching between electrode and biological tissue, and tissue damage is decreased. This review discusses nerve microelectrodes based on flexible electrode materials and substrate materials. Simultaneously, different structural designs of neural microelectrodes are reviewed. However, flexible electrode probes are difficult to implant into the brain. Only with the aid of certain auxiliary devices, can the implant be safe and reliable. The implantation method of the nerve microelectrode is also reviewed.
All human activity is associated with the generation of electrical signals. These signals are collectively referred to as electrical physiology (EP) signals (e.g., electrocardiogram, electroencephalogram, electromyography, electrooculography, etc.), which can be recorded by electrodes. EP electrodes are not only widely used in the study of primary diseases and clinical practice, but also have potential applications in wearable electronics, human–computer interface, and intelligent robots. Various technologies are required to achieve such goals. Among these technologies, adhesion and stretchable electrode technology is a key component for rapid development of high-performance sensors. In last decade, remarkable efforts have been made in the development of flexible and high-adhesive EP recording systems and preparation technologies. Regarding these advancements, this review outlines the design strategies and related materials for flexible and adhesive EP electrodes, and briefly summarizes their related manufacturing techniques.
In recent years, optoelectronics and related industries have developed rapidly. As typical optoelectronics devices, photodetectors (PDs) are widely applied in various fields. The functional materials in traditional PDs exhibit high hardness, and the performance of these rigid detectors is thus greatly reduced upon their stretching or bending. Therefore, the development of new flexible PDs with bendable and foldable functions is of great significance and has much interest in wearable, implantable optoelectronic devices. Graphene with excellent electrical and optical performance constructed on various flexible and rigid substrates has great potential in PDs. In this review, recent research progress on graphene-based flexible PDs is outlined. The research states of graphene conductive films are summarized, focusing on PDs based on single-component graphene and mixed-structure graphene, with a systematic analysis of their optical and mechanical performance, and the techniques for optimizing the PDs are also discussed. Finally, a summary of the current applications of graphene flexible PDs and perspectives is provided, and the remaining challenges are discussed.
With the development of the Internet of things, artificial intelligence, and wearable devices, massive amounts of data are generated and need to be processed. High standards are required to store and analyze this information. In the face of the explosive growth of information, the memory used in data storage and processing faces great challenges. Among many types of memories, memristors have received extensive attentions due to their low energy consumption, strong tolerance, simple structure, and strong miniaturization. However, they still face many problems, especially in the application of artificial bionic synapses, which call for higher requirements in the mechanical properties of the device. The progress of integrated circuit and micro-processing manufacturing technology has greatly promoted development of the flexible memristor. The use of a flexible memristor to simulate nerve synapses will provide new methods for neural network computing and bionic sensing systems. In this paper, the materials and structure of the flexible memristor are summarized and discussed, and the latest configuration and new materials are described. In addition, this paper will focus on its application in artificial bionic synapses and discuss the challenges and development direction of flexible memristors from this perspective.
Monolayer nanosheets have gained significant attention as functional materials and also in photo/electrocatalysis due to their unique physical/chemical properties, abundance of highly exposed coordination sites, edges, and corner sites, motivating the pursuit of highly active monolayer nanosheets. NiFe-based layered double hydroxide (NiFe-LDH) nanosheets have been regarded as the most efficient electrocatalysis for oxygen evolution. However, the limited catalytic active site and the stacking layer limited the performance. Therefore, by introducing highly electroactive Co ions into monolayer NiFe-LDH, the obtained ternary NiFeCo-LDH monolayer structure possessed an increased concentration of defect (oxygen and metal vacancies), providing enough unsaturated coordination sites, benefitting the electrocatalytic water oxidation, as also explained by the density functional theory (DFT). This work reported an efficient strategy for the synthesis of ternary monolayer LDH in the application of energy conversion and storage.