We developed cell-free implants, comprising carbodiimide crosslinked recombinant human collagen (RHC), to enable corneal regeneration by endogenous cell recruitment, to address the worldwide shortage of donor corneas. Patients were grafted with RHC implants. Over four years, the regenerated neo-corneas were stably integrated without rejection, without the long immunosuppression regime needed by donor cornea patients. There was no recruitment of inflammatory dendritic cells into the implant area, whereas, even with immunosuppression, donor cornea recipients showed dendritic cell migration into the central cornea and a rejection episode was observed. Regeneration as evidenced by continued nerve and stromal cell repopulation occurred over the four years to approximate the micro-architecture of healthy corneas. Histopathology of a regenerated, clear cornea from a regrafted patient showed normal corneal architecture. Donor human cornea grafted eyes had abnormally tortuous nerves and stromal cell death was found. Implanted patients had a 4-year average corrected visual acuity of 20/54 and gained more than 5 Snellen lines of vision on an eye chart. The visual acuity can be improved with more robust materials for better shape retention. Nevertheless, these RHC implants can achieve stable regeneration and therefore, represent a potentially safe alternative to donor organ transplantation.
Purpose. To develop a simple corneal substitute from cross-linked collagen. methods. Porcine type I collagen (10%; pH 5), was mixed with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The final homogenous solution was molded to corneal dimensions, cured, and then implanted into rabbits and minipigs by lamellar keratoplasty. The implants were followed for up to 6 months after surgery. Clinical examinations of the cornea included detailed slit lamp biomicroscopy, in vivo confocal microscopy, topography and esthesiometry for nerve function. Histopathologic examinations were also performed on rabbit corneas harvested after 6 months. results. Cross-linked collagen (refractive index, 1.35) had optical clarity superior to human corneas. Implanted into rabbit and porcine corneas, only 1 of 24 of the surgical corneas showed a slight haze at 6 months after surgery. All other implants showed no adverse reactions and remained optically clear. Topography showed a smooth surface and a profile similar to that of the contralateral nonsurgical eye. The implanted matrices promoted regeneration of corneal cells, tear film, and nerves. Touch sensitivity was restored, indicating some restoration of function. The corneas with implants showed no significant loss of thickness and demonstrated stable host–graft integration. conclusions. Collagen can be adequately stabilized, using water soluble carbodiimides as protein cross-linking reagents, in the fabrication of corneal matrix substitutes for implantation. The simple cross-linking methodology would allow for easy fabrication of matrices for transplantation in centers where there is a shortage of corneas, or where there is need for temporary patches to repair perforations in emergency situations.