Mitchell Watsky

Dr. Mitchell Watsky

1. Department of Cellular Biology and Anatomy, Medical College of Georgia, Augusta University, Augusta, GA 30907, USA</br> 2. James and Jean Culver Vision Discovery Institute, Medical College of Georgia, Augusta University, Augusta, GA 30907, USA
orcid

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 1991 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
JRJames Rae
James Rae
KCKim Cooper
Kim Cooper
PGPeter Gates
Peter Gates
Mitchell WatskyMitchell Watsky
Mitchell Watsky

10 December 1999 in Science
Verified
Journal Article
Closed access
PDF file
MGMay Griffith
May Griffith
RORosemarie Osborne
Rosemarie Osborne
RMRejean Munger
Rejean Munger
XXXiaojuan Xiong
Xiaojuan Xiong
CDCharles J. Doillon
Charles J. Doillon
Mitchell WatskyMitchell Watsky
Mitchell Watsky
Human corneal equivalents comprising the three main layers of the cornea (epithelium, stroma, and endothelium) were constructed. Each cellular layer was fabricated from immortalized human corneal cells that were screened for use on the basis of morphological, biochemical, and electrophysiological similarity to their natural counterparts. The resulting corneal equivalents mimicked human corneas in key physical and physiological functions, including morphology, biochemical marker expression, transparency, ion and fluid transport, and gene expression. Morphological and functional equivalents to human corneas that can be produced in vitro have immediate applications in toxicity and drug efficacy testing, and form the basis for future development of implantable tissues.

1 October 2008 in Biomaterials
Verified
Journal Article
Closed access
MRMehrdad Rafat
Mehrdad Rafat
FLFengfu Li
Fengfu Li
PFPer Fagerholm
Per Fagerholm
NLNeil Satish Lagali
Neil Satish Lagali
Mitchell WatskyMitchell Watsky
Mitchell Watsky
MGMay Griffith
May Griffith

1 March 2008 in Biomaterials
Verified
Journal Article
Closed access
WLWenguang Liu
Wenguang Liu
KMKimberley Merrett
Kimberley Merrett
MGMay Griffith
May Griffith
PFPer Fagerholm
Per Fagerholm
SDSubhadra Dravida
Subhadra Dravida
FLFengfu Li
Fengfu Li

1 May 2006 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
YLYuwen Liu
Yuwen Liu
LGLisha Gan
Lisha Gan
DCDavid J. Carlsson
David J. Carlsson
PFPer Fagerholm
Per Fagerholm
NLNeil Satish Lagali
Neil Satish Lagali
MGMay Griffith
May Griffith
Purpose. To develop a simple corneal substitute from cross-linked collagen. methods. Porcine type I collagen (10%; pH 5), was mixed with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The final homogenous solution was molded to corneal dimensions, cured, and then implanted into rabbits and minipigs by lamellar keratoplasty. The implants were followed for up to 6 months after surgery. Clinical examinations of the cornea included detailed slit lamp biomicroscopy, in vivo confocal microscopy, topography and esthesiometry for nerve function. Histopathologic examinations were also performed on rabbit corneas harvested after 6 months. results. Cross-linked collagen (refractive index, 1.35) had optical clarity superior to human corneas. Implanted into rabbit and porcine corneas, only 1 of 24 of the surgical corneas showed a slight haze at 6 months after surgery. All other implants showed no adverse reactions and remained optically clear. Topography showed a smooth surface and a profile similar to that of the contralateral nonsurgical eye. The implanted matrices promoted regeneration of corneal cells, tear film, and nerves. Touch sensitivity was restored, indicating some restoration of function. The corneas with implants showed no significant loss of thickness and demonstrated stable host–graft integration. conclusions. Collagen can be adequately stabilized, using water soluble carbodiimides as protein cross-linking reagents, in the fabrication of corneal matrix substitutes for implantation. The simple cross-linking methodology would allow for easy fabrication of matrices for transplantation in centers where there is a shortage of corneas, or where there is need for temporary patches to repair perforations in emergency situations.

1 March 2009 in Biomaterials
Verified
Journal Article
Closed access
WLWenguang Liu
Wenguang Liu
CDChao Deng
Chao Deng
CMChristopher R. McLaughlin
Christopher R. McLaughlin
PFPer Fagerholm
Per Fagerholm
NLNeil Satish Lagali
Neil Satish Lagali
MGMay Griffith
May Griffith