Pavel Skarolek

Mr. Pavel Skarolek

Department of Electrical Drives and Traction
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019
Verified
Conference Paper
Closed access
Pavel SkarolekPavel Skarolek
Pavel Skarolek
JLJiri Lettl
Jiri Lettl
Three methods of cooling gallium nitride (GaN) transistors have been tested and directly compared together. Under similar conditions, top side cooled GaN was compared to the bottom side cooled type; both were of the same electrical parameters and were mounted on FR4 (fibreglass resin) and IMS (insulated metal substrate) printed circuit boards. At equal dissipated power the proposed bottom side cooled transistor on IMS board reaches half the temperature compared to the top side cooled one and one fourth of the temperature compared to the bottom side cooled GaN on FR4 board. A High speed driver is placed close to the transistor also on the IMS board to reduce parasitic inductance of the gate driving path from control board to the high power side on the IMS board.

22 November 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Pavel SkarolekPavel Skarolek
Pavel Skarolek
FFFilipp Frolov
Filipp Frolov
OLOndrej Lipcak
Ondrej Lipcak
JLJiří Lettl
Jiří Lettl
Gallium nitride (GaN) devices are becoming more popular in power semiconductor converters. Due to the absence of the freewheeling substrate diode, the reverse conduction region is used in GaN transistors to conduct the freewheeling current. However, the voltage drop across the device in the reverse conduction mode is relatively high, causing additional power losses. These losses can be optimized by adequately adjusting the dead-time issued by the microcontroller. The dead-time loss minimization strategies presented in the literature have the common disadvantage that either additional hardware or specific converter data are needed for their proper operation. Therefore, this paper’s motivation is to present a novel dead-time loss minimization method for GaN-based high-frequency switching converters for electric drives that does not impose additional requirements on the hardware design phase and converter data acquisition. The method is based on optimizing the current controllers’ output with a simple perturb-and-observe tracker. The experimental results show that the proposed approach can minimize the dead-time losses over the whole drive’s operating range at the cost of only a moderate increase in software complexity.

1 September 2019
Verified
Conference Paper
Open access
Pavel SkarolekPavel Skarolek
Pavel Skarolek
JLJiri Lettl
Jiri Lettl

1 September 2017
Verified
Conference Paper
Closed access
Pavel SkarolekPavel Skarolek
Pavel Skarolek
JLJiri Lettl
Jiri Lettl

1 September 2018
Verified
Conference Paper
Closed access
Pavel SkarolekPavel Skarolek
Pavel Skarolek
JLJiri Lettl
Jiri Lettl

7 May 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Pavel SkarolekPavel Skarolek
Pavel Skarolek
OLOndrej Lipcak
Ondrej Lipcak
JLJiří Lettl
Jiří Lettl
The ever-increasing demands on the efficiency and power density of power electronics converters lead to the replacement of traditional silicon-based components with new structures. One of the promising technologies represents devices based on Gallium-Nitride (GaN). Compared to silicon transistors, GaN semiconductor switches offer superior performance in high-frequency converters, since their fast switching process significantly decreases the switching losses. However, when used in hard-switched converters such as voltage-source inverters (VSI) for motor control applications, GaN transistors increase the power dissipated due to the current conduction. The loss increase is caused by the current-collapse phenomenon, which increases the dynamic drain-source resistance of the device shortly after the turn-on. This disadvantage makes it hard for GaN converters to compete with other technologies in electric drives. Therefore, this paper offers a purely software-based solution to mitigate the negative consequences of the current-collapse phenomenon. The proposed method is based on the minimum pulse length optimization of the classical 7-segment space-vector modulation (SVM) and is verified within a field-oriented control (FOC) of a three-phase permanent magnet synchronous motor (PMSM) supplied by a two-level GaN VSI. The compensation in the control algorithm utilizes an offline measured look-up table dependent on the machine input power.