Although still widely used due to its robustness, reliability, and low cost, induction motor (IM) has a disadvantage of more complicated mathematical description than permanent magnet AC machines. In high-demanding applications, the decoupled control of the machine’s flux and torque along with the proper function of selected efficiency-improving and flux-weakening algorithms can be achieved only if the IM parameters are known with sufficient accuracy. For parameter estimation, many algorithms have been proposed in the literature so far. Due to its simple and straightforward implementation, one of the popular estimation strategies is the model reference adaptive system (MRAS). However, MRAS-based algorithms for a specific parameter estimation tend to be sensitive to other machine parameters. For instance, most of the proposed MRAS algorithms do not consider the influence of the phenomena such as iron losses and load-dependent saturation. Since one of the most performance-decisive parameters of the popular rotor flux-oriented control (RFOC) are the magnetizing inductance and the rotor resistance, this paper aims to present a novel MRAS-based magnetizing inductance estimator (Lm-MRAS) with the included effect of iron losses. Furthermore, to enable the identification of the load-dependent saturation, another MRAS with included iron losses based on reactive power is proposed to work parallelly with Lm-MRAS, since under load conditions, the rotor resistance mismatch causes RFOC detuning. The adaptation law of the Lm-MRAS is obtained using the Lyapunov function approach and further examined using small-signal analysis. The proposed algorithms are verified on a 3.6 kW IM drive both in simulations and experiments.
Today’s modern control strategies of an induction motor (IM) drive require a power source with an adjustable output voltage frequency and amplitude. The most commonly used converter topology is a two-level voltage-source inverter (VSI). However, the utilization of a VSI introduces additional voltage and current distortion, which leads to additional power losses in the machine’s magnetic circuit. Both the transistor switching frequency and the type of the inverter control determine the total harmonic distortion (THD) of the motor’s phase currents. In this paper, the influence of the inverter DC-link voltage on the iron losses of an IM controlled by a predictive torque control (PTC) is presented. It is shown that if the IM drive operates below the rated speed, it is possible to modify the PTC algorithm to reduce the additional iron losses caused by the non-harmonic inverter output voltage. The control of the DC-link voltage is achieved by using a silicon-controlled rectifier. Experiments were conducted on a 5.5 kW IM controlled by PTC, and the results are compared against a sinusoidal voltage supply created by a synchronous generator.
24 March 2025 in IEEE Transactions on Transportation Electrification
The dual-inverter (DI) with galvanically isolated dc supplies offers advantages such as multilevel and fault-tolerant operation, superior dc voltage utilization, and simple control, making it particularly attractive for traction applications. The DI provides significant flexibility in output voltage synthesis by utilizing two conventional voltage-source inverters (VSIs) to supply each end of the load. This article leverages that flexibility by proposing several modulation strategies, where one inverter operates in a six-step (square-wave) mode, and the other utilizes a modified space vector pulse width modulation (SVPWM) or discontinuous pulse width modulation (DPWM). These strategies efficiently reduce switching losses while maintaining low implementation complexity through the reference signal deformation approach. The proposed modulations are theoretically analyzed for switching loss reduction and experimentally validated on an induction machine under closed-loop field-oriented control to confirm their effectiveness compared to conventional approaches.
Gallium nitride (GaN) devices are becoming more popular in power semiconductor converters. Due to the absence of the freewheeling substrate diode, the reverse conduction region is used in GaN transistors to conduct the freewheeling current. However, the voltage drop across the device in the reverse conduction mode is relatively high, causing additional power losses. These losses can be optimized by adequately adjusting the dead-time issued by the microcontroller. The dead-time loss minimization strategies presented in the literature have the common disadvantage that either additional hardware or specific converter data are needed for their proper operation. Therefore, this paper’s motivation is to present a novel dead-time loss minimization method for GaN-based high-frequency switching converters for electric drives that does not impose additional requirements on the hardware design phase and converter data acquisition. The method is based on optimizing the current controllers’ output with a simple perturb-and-observe tracker. The experimental results show that the proposed approach can minimize the dead-time losses over the whole drive’s operating range at the cost of only a moderate increase in software complexity.
25 January 2024 in IEEE Transactions on Power Electronics
This paper introduces a novel overmodulation strategy tailored for dual-inverter topologies with galvanically isolated DC-links and evenly distributed DC-link voltage. The core contribution of the paper is the utilization of the multilevel capabilities of the dual-inverter topology. At the maximum modulation index, the presented overmodulation method achieves what is referred to as a 12-step operation. The 12-step operation improves the voltage waveform and offers superior harmonic performance compared to the conventional 6-step operation. The utilized approach leverages a hybrid Space Vector Pulse Width Modulation (SVPWM) method, a well-established technique in two-level inverters, to achieve this extended operation range. Furthermore, the paper presents a nonlinear gain compensation characteristic vital for real-time motor control applications and provides a comparative analysis of the modulation's harmonic performance. The proposed approach is validated through simulations and experiments. The experiments were conducted using a custom inverter based on Gallium-Nitride (GaN) transistors where simple volt/hertz control of an induction motor was programmed. The results of these experiments affirm the strategy's effectiveness, showcasing superior current waveform quality and a smooth transition from linear mode to 12-step operation while keeping a simple implementation of the algorithm.
This paper investigates the optimal stator voltage angle in a rotor flux‐oriented system of an induction machine drive, aiming to maximise machine torque while operating in a deep field weakening region. Here, torque maximisation leads to maximum torque per voltage control, as only voltage constraints are relevant in this region due to high back‐electromotive force. Previous studies have predominantly focused on field‐weakening operation and torque maximisation, assuming a constant synchronous speed. However, for a given rotor speed, the variation in the dq voltage components impacts the slip speed, thereby influencing the synchronous speed. Therefore, this paper proposes enhanced analytical expressions to address this limitation. It is shown that after a linearisation around a suitable operating point, a closed‐form algebraic equation for calculating the speed and parameter‐dependent optimal voltage angle for torque maximisation can be obtained. The theoretical analysis is supported by numerical and experimental results. The presented linearised expression is proven to be an effective tool for the analytical calculation of the optimal voltage angle, making it suitable for real‐time control applications. It is shown that the proposed approach achieves higher drive torque and efficiency than the conventional voltage component distribution.