Gallium nitride (GaN) devices are becoming more popular in power semiconductor converters. Due to the absence of the freewheeling substrate diode, the reverse conduction region is used in GaN transistors to conduct the freewheeling current. However, the voltage drop across the device in the reverse conduction mode is relatively high, causing additional power losses. These losses can be optimized by adequately adjusting the dead-time issued by the microcontroller. The dead-time loss minimization strategies presented in the literature have the common disadvantage that either additional hardware or specific converter data are needed for their proper operation. Therefore, this paper’s motivation is to present a novel dead-time loss minimization method for GaN-based high-frequency switching converters for electric drives that does not impose additional requirements on the hardware design phase and converter data acquisition. The method is based on optimizing the current controllers’ output with a simple perturb-and-observe tracker. The experimental results show that the proposed approach can minimize the dead-time losses over the whole drive’s operating range at the cost of only a moderate increase in software complexity.
Three-phase LLC resonant converters are attractive for high-power applications due to their reduced output current ripple, improved thermal distribution, and inherent scalability. However, component tolerances in resonant tanks often cause phase current imbalance, leading to asymmetric conduction losses among the converter phases, output ripple, and uneven thermal stress. This paper proposes a simple online balancing algorithm that dynamically adjusts input voltage phase shifts to equalize RMS phase currents in real-time. The presented approach is capable of achieving a low unbalance factor even under severe mismatch conditions. The algorithm was validated on an 11 kW LLC prototype, achieving operation with an unbalance factor less than 2% over the full operating frequency range. Results demonstrate improved electrical symmetry and reduced thermal stress, confirming the practicality of the proposed strategy for high-power three-phase LLC converters.
This paper presents a new strategy for a three-phase LLC resonant converter operating over an extended output-voltage range. The converter employs three-phase, two-phase full-bridge, and single-phase half-bridge modes to regulate the output voltage from approximately 400 V to 100 V within the specified switching-frequency range. In conventional fixed half-bridge operation, one phase continuously transfers power, resulting in unequal component utilization and localized thermal loading. The proposed rotating phase-shedding method periodically rotates the active, supporting, and inactive states among the three converter phases. Consequently, the accumulated current stress and power losses are distributed uniformly without requiring additional power components. The operating principles and phase-rotation sequence are analyzed, and the proposed strategy is experimentally validated on an 11 kW three-phase LLC resonant converter prototype. Measured current waveforms confirm the correct transfer of the active state among the phases. Thermal-camera measurements demonstrate a more uniform temperature distribution across the secondary-side rectifier diodes compared with fixed phase-shedding operation, confirming improved component utilization and thermal performance.