Marcio Mendonca

Prof. Dr. Marcio Mendonca

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Complementary Therapies in Medicine
Verified
Journal Article
Closed access
MRManuel da Fonseca Rodrigues
Manuel da Fonseca Rodrigues
MRMarisa Lupes Rodrigues
Marisa Lupes Rodrigues
KBKimberly Suellen Bueno
Kimberly Suellen Bueno
JAJanaina Paula Aroca
Janaina Paula Aroca
VCVeridiana Camilotti
Veridiana Camilotti
MMMarcio Mendonca
Marcio Mendonca

11 April 2022 in Complementary Therapies in Clinical Practice
Verified
Journal Article
Closed access
JAJanaina Paula Aroca
Janaina Paula Aroca
PCPoliana Maria de Faveri Cardoso
Poliana Maria de Faveri Cardoso
JFJamille Favarão
Jamille Favarão
MZMauricio Matté Zanini
Mauricio Matté Zanini
VCVeridiana Camilotti
Veridiana Camilotti
LALuciana Azevedo-Alanis
Luciana Azevedo-Alanis

8 September 2020 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
LCLúcio P.G. Chicarelli
Lúcio P.G. Chicarelli
MWMariana B.F. Webber
Mariana B.F. Webber
JAJoão P.A. Amorim
João P.A. Amorim
ARAna L.C.A. Rangel
Ana L.C.A. Rangel
VCVeridiana Camilotti
Veridiana Camilotti
MMMarcio Mendonca
Marcio Mendonca
Objectives Conduct a histological comparison of the pulp response to different materials, with a focus on the continuity and morphology of the mineralized barrier after direct pulp capping. Materials and Methods One hundred and eight maxillary first molars of 54 Wistar rats were subject to direct pulp capping and divided into three groups according to the materials used: calcium hydroxide (CH), mineral trioxide aggregate (MTA), and Biodentine. All cavities were sealed, and the animals were euthanized at 7, 14, and 21 days. Descriptive histological evaluation of the inflammation and formation of the mineralized barrier was performed. Statistical Analysis Statistical analyses were performed using the Kruskal–Wallis test, which was complemented by the Dunn test; differences with p < 0.05 were considered statistically significant. Results The results showed that MTA and Biodentine elicited less intense inflammatory reactions than CH. With respect to the formation and quality of the dentin barrier formed, differences were observed at 21 days between the analyzed groups; the best results being obtained following treatment with MTA and Biodentine. Conclusion MTA and Biodentine induced formation of a more continuous and uniform mineralized barrier with less intense pulp response than CH.

1 January 2024 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
TZThayna Carolina Zeni
Thayna Carolina Zeni
PCPoliana Maria de Faveri Cardoso
Poliana Maria de Faveri Cardoso
RVRafael da Silva Vanolli
Rafael da Silva Vanolli
MMMarcio Mendonca
Marcio Mendonca
JUJulio Katuhide Ueda
Julio Katuhide Ueda
VCVeridiana Camilotti
Veridiana Camilotti
Zeni TC, et al. Restor Dent Endod. 2024 Mar;49:e15. https://doi.org/10.5395/rde.2024.49.e15

1 February 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
GLGabriéla Melo Lopes
Gabriéla Melo Lopes
TPTaiana Paola Prado
Taiana Paola Prado
VCVeridiana Camilotti
Veridiana Camilotti
PBPaula Bernardon
Paula Bernardon
MMMarcio Mendonca
Marcio Mendonca
JUJulio Katuhide Ueda
Julio Katuhide Ueda

1 January 2008 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
EDEduardo Dalli'MAgro
Eduardo Dalli'MAgro
MSMário Alexandre Coelho Sinhoreti
Mário Alexandre Coelho Sinhoreti
ACAmérico Bortolazzo Correr
Américo Bortolazzo Correr
RCRafael Leonardo Xediek Consani
Rafael Leonardo Xediek Consani
ESEliseu Augusto Sicoli
Eliseu Augusto Sicoli
LCLourenço Correr-Sobrinho
Lourenço Correr-Sobrinho
This study evaluated the bond strength and Knoop hardness of Z250 composite resin, light activated with XL2500 curing unit, using different protocols: continuous mode - high intensity (CH) (700 mW/cm²) for 20 s; continuous mode - low intensity (CL) (150 mW/cm²) for 20 s; and pulse-delay with 150 mW/cm² for 2(P2), 3(P3), 5(P5), 10(P10) or 15 s (P15), with a 1-min delay, followed by 700 mW/cm² for 20 s. For the push-out test (n=10), the bond strength values were obtained using a universal test machine at a crosshead speed of 0.5 mm/min. For Knoop hardness (n=5), the specimens were made using the same light-activation protocols. The hardness measurements were made with a hardness tester at six depths (top, 1, 2, 3, 4, and 5 mm). The data were subjected to ANOVA and Tukey's test at 5% significance level. For bond strength, CL and P5 presented significantly higher mean values (p0.05) between P2, P3, P10, P15 and CH. For Knoop hardness, CH and P15 presented the highest mean values from top surface up to 4 mm depth , while CL presented the lowest hardness mean values (p<0.05). From the depth of 3 mm to 5 mm, the mean values of all groups were significantly lower (p<0.05) than those recorded on top surface. In conclusion, for the pulse-delay method, the initial exposure time can influence bond strength and Knoop hardness of composites.