Julio Katuhide Ueda

Julio Katuhide Ueda

Auto-generated profile, based on publicly available information

Julio Katuhide Ueda

Universidade Estadual do Oeste do Paraná (UNIOESTE)

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
TZThayna Carolina Zeni
Thayna Carolina Zeni
PCPoliana Maria de Faveri Cardoso
Poliana Maria de Faveri Cardoso
RVRafael da Silva Vanolli
Rafael da Silva Vanolli
MMMarcio Mendonca
Marcio Mendonca
JUJulio Katuhide Ueda
Julio Katuhide Ueda
VCVeridiana Camilotti
Veridiana Camilotti
Zeni TC, et al. Restor Dent Endod. 2024 Mar;49:e15. https://doi.org/10.5395/rde.2024.49.e15

1 February 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
GLGabriéla Melo Lopes
Gabriéla Melo Lopes
TPTaiana Paola Prado
Taiana Paola Prado
VCVeridiana Camilotti
Veridiana Camilotti
PBPaula Bernardon
Paula Bernardon
MMMarcio Mendonca
Marcio Mendonca
JUJulio Katuhide Ueda
Julio Katuhide Ueda

9 March 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
VCVeridiana Camilotti
Veridiana Camilotti
ADAnna Caroliny Detogni
Anna Caroliny Detogni
GAGláucia Maria Bovi Ambrosano
Gláucia Maria Bovi Ambrosano
MMMarcio Mendonca
Marcio Mendonca
JUJulio Katuhide Ueda
Julio Katuhide Ueda
MGMário Fernando De Goes
Mário Fernando De Goes
The objective of this study was to evaluate in vitro the roughness and surface morphology of composite resins (CRs) stored for 180 days in acidic solutions present in the diet. Three micro-hybrid composite resins were used in this study (Charisma, Opallis, and Esthet-X). Fifty-one specimens were made of each material with 4 mm in diameter and 2 mm thick with the aid of an elastomer matrix. After photoactivation for 40 seconds (Elipar Free-Light / 3M ESPE), the specimens were stored in distilled water for 24 hours at 37ºC for subsequent surface polishing with Soft Lex / 3M ESPE discs in fine and extra-fine granulation. Then, the specimens were dried with absorbent paper and the surface roughness was measured using a rugosimeter. The specimens were then randomly divided into five groups (n=10) according to the tested solutions: DW - Distilled water (pH 5.30); RW - Red Wine / Trapiche Syha Ind. Argentina red wine (pH 3.68); CK – Coke / Coca Cola Co. (pH 2.73), OJ - Orange juice / Purity Cocamar (pH 3.58) and LBS - lactate buffer solution (pH 2.74). The tested solutions were changed daily. The surface roughness test was repeated after 15, 90 and 180 days of immersion. The average values of surface roughness were submitted to LSmeans analysis and Tukey-Kramer test, at a significance level of 5%. The results of surface roughness revealed that all CRs showed a significant increase in the roughness values over time for all tested solutions.

7 September 2023 in Journal of Advances in Medicine and Medical Research
Verified
Journal Article
Closed access
PDF file
FFFelipe Gustavo Fachin
Felipe Gustavo Fachin
PCPoliana Maria de Faveri Cardoso
Poliana Maria de Faveri Cardoso
JUJulio Katuhide Ueda
Julio Katuhide Ueda
VCVeridiana Camilotti
Veridiana Camilotti
MMMarcio Mendonca
Marcio Mendonca

6 February 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
BLBruna Caroline de Oliveira Lima
Bruna Caroline de Oliveira Lima
TZThayna Carolina Zeni
Thayna Carolina Zeni
MMMarcio Mendonca
Marcio Mendonca
JRJoão Vitor Oribka Roque
João Vitor Oribka Roque
JUJulio Katuhide Ueda
Julio Katuhide Ueda
VCVeridiana Camilotti
Veridiana Camilotti
This study aimed to assess the effects of adding chlorhexidine (CHX) to different adhesive systems on antibacterial activity and bond strength after 24 hours and 30 days under in vitro conditions. A total of 210 bovine incisor crowns and divided into three groups, based on the adhesive system: Single Bond Plus (SB), Clearfil SE Bond (CL), and AdheSE Primer and Bond (AD). All groups were subdivided by CHX concentration (n=7): no CHX, CHX applied before the adhesive (CPA), and the adhesive incorporated with 0.5% CHX, 1.0% CHX, and 2.0% CHX. The micro shear test was conducted on one-half of the specimens after 24 hours, and on the other half after 30 days. Antibacterial activity was evaluated using the agar diffusion test with Streptococcus mutans. The bond strength variable was assessed using the factorial analysis of variance for repeated measurements, whereas the variable of the bacterial halo size was subjected to the Kruskal–Wallis nonparametric test. The significance level was 5% for both tests. The qualitative variable of fracture pattern was assessed by descriptive statistical analysis. Thus, CHX concentration of 2% (10.80 ±2.83) and CPA (9.95 ±1.47) (p >0.05) helped to increase the bond strength values for most adhesive systems, whereas CL had the highest bond strength values. The CL adhesive system also presented the best results in the antibacterial test with S.mutans.

31 July 2023 in REVISTA FOCO
Verified
Journal Article
Open access
PDF file
ADAnna Caroliny Detogni
Anna Caroliny Detogni
MSMarina Pereira Silva
Marina Pereira Silva
MSMário Alexandre Coelho Sinhoreti
Mário Alexandre Coelho Sinhoreti
JUJulio Katuhide Ueda
Julio Katuhide Ueda
VCVeridiana Camilotti
Veridiana Camilotti
O objetivo deste estudo foi avaliar a influência da água ozonizada utilizada como solução de limpeza dentinária previamente a aplicação dos sistemas adesivos universais Prime & Bond Universal e Single Bond Universal na resistência de união das resinas compostas bulk fill flow Spectra Basic e Filtek Bulk Fill Flow. Foram selecionados 40 dentes anteriores bovinos, divididos em 4 grupos (n=10): OZ24DENT: limpeza da dentina com água ozonizada a 4 ppm, seguido do uso do sistema adesivo Prime & Bond Universal e resina bulk fill flow Spectra Basic, com armazenamento por 24h; OZ30DENT: limpeza da dentina com água ozonizada a 4 ppm, seguido do uso do sistema adesivo Prime & Bond Universal e resina bulk fill flow Spectra Basic, com armazenamento por 30 dias; OZ243M: limpeza da dentina com água ozonizada a 4 ppm, seguido do uso do sistema adesivo Single Bond Universal e resina Filtek Bulk Fill Flow, com armazenamento por 24h; e OZ303M: limpeza da dentina com água ozonizada a 4 ppm, seguido do uso do sistema adesivo Single Bond Universal e resina Filtek Bulk Fill Flow, com armazenamento por 30 dias. O tratamento das superfícies destes foi realizado de acordo com as recomendações de cada fabricante e protocolo de limpeza superficial. Após a confecção dos corpos de prova, as amostras foram armazenadas por períodos de 24 horas ou 30 dias, e posteriormente, o teste de resistência adesiva por microcisalhamento na máquina universal de ensaios foi executado. Os dados obtidos foram submetidos à análise estatística. De forma geral, não foram observados resultados de resistência de união estatisticamente significantes nas análises intra e intergrupos, independentemente do terço coronário e tempo de armazenamento. Conclui-se que a água ozonizada, quando utilizada como agente de limpeza dentinária previamente aos sistemas adesivos universais Prime Bond Universal e Single Bond Universal, não interfere na resistência de união das resinas compostas bulk fill flow, podendo ser empregada na rotina clínica de maneira satisfatória.