This paper proposes an energy management system (EMS) of direct current (DC) microgrid. In order to implement the proposed EMS, the control and operation method of EMS is presented in this work. While most of the studies have individually examined the grid-connected mode used in building and the stand-alone operation mode applicable to the island, the proposed EMS allows it to be used in both grid-connected mode and stand-alone mode with 10 modes. In order to determine each mode in EMS, not only the amount of generated power, load power, and the state of charge (SOC) of the battery, but also the rated power of the energy storage system (ESS) converter that performs charging and discharging operations is additionally considered. Thus, various uncertainties that may occur in the actual DC microgrid environment can be improved. A laboratory-scale DC microgrid is fabricated to conduct experimental validation of proposed EMS. Experiments of DC microgrid with proposed EMS were performed for each mode, and the experiment waveforms of each power conversion device are included in detail.
Recent developments in high-density lithium-ion battery technologies have greatly expanded the electric vehicle (EV) market. Due to the fact that the rapid charging of an EV battery pack while maintaining a suitable cell cycle life is necessary for further growth of the EV market, we herein propose an innovative adaptive rapid charging pattern that minimizes cell degradation and reflects the degradation characteristics. This technology is advantageous in that cells can be developed by analyzing the charging characteristics in the latter stages of cell development of the rapid charging pattern, while also considering the complexity and heterogeneity of the manufacturing process. Furthermore, the battery charging pattern is optimized and controlled in real-time by reflecting the characteristics of the battery module and pack degradation as the cycle number is increased. More specifically, we present a preliminary study that simplifies the implementation of the new optimization pattern to improve the cell cycle life by over 45% in comparison to conventional fast charging patterns, and to address the drop in capacity in the latter half of cell life during rapid charging.
This paper investigates the fault-tolerance control of a multilevel cascaded NPC/H-bridge (CNHB) inverter. The fault-tolerance control method has been widely used for multilevel inverters, such as the neutral-point voltage-shifting control, which can operate for a certain period of time by compensating for the phase voltage of a faulty stack even if one stack is broken. Even though the three-phase equilibrium is maintained in the case of failure by using the conventional neutral-point voltage-shifting control, an imbalance in the output power occurs between each stack, which causes problems for maintenance and lifetime. Therefore, this paper proposes a fault-tolerance control that can maintain three-phase equilibrium in a case of stack failures and minimize power imbalances between the stacks. The problem of the conventional neutral-point voltage-shifting control is presented based on the output power. In addition, the power imbalance is improved by performing selective neutral-point voltage-shifting control according to the reference voltage range. To verify the principle and feasibility of the proposed neutral-point voltage-shifting control method, a simulation and an experiment are implemented with the CNHB inverter.
This paper studies a second order generalized integrator-frequency locked loop (SOGI-FLL) control scheme applicable for 3-phase alternating current/direct current (AC/DC) pulse width modulation (PWM) converters used in DC distribution systems. The 3-phase AC/DC PWM converter is the most important power conversion system of DC distribution, since it can boost 380 Vrms 3-phase line-to-line AC voltage to 700 Vdc DC output with various DC load devices and grid voltages. The direct-quadrature (d-q) transformation, positive sequence voltage extraction, proportional integral (PI) voltage/current control, and phase locked loop (PLL) are necessary to control the 3-phase AC/DC PWM converter. Besides, a digital filter, such as low pass filter and all pass filter, are essential in the conventional synchronous reference frame-phase locked loop (SRF-PLL) method to eliminate the low order harmonics of input. However, they limit the bandwidth of the controller, which directly affects the output voltage and load of 3-phase AC/DC PWM converter when sever voltage fluctuation, such as sag, swell, etc. occurred in the grid. On the other hand, the proposed control method using SOGI-FLL is able to do phase angle detection, positive sequence voltage extraction, and harmonic filtering without additional digital filters, so that more stable and fast transient control is achieved in the DC distribution system. To verify the improvement of the characteristics in the unbalanced voltage and frequency fluctuation of the grid, a simulation and experiment are implemented with 50 kW 3-phase AC/DC PWM converter used in DC distribution.
This paper proposes a novel pulse width modulation (PWM) for a three-level neutral point clamped (NPC) voltage source inverter (VSI). When the conventional PWM method is used in three-level NPC VSI, dead time is required to prevent a short circuit caused by the operation of complementary devices on the upper and lower arms. However, current distortion is increased because of the dead time and it can also cause a voltage unbalance in the dc-link. To solve this problem, we propose a zero dead-time width modulation (ZDPWM) which does not require dead time used in complementary operation. The proposed technique applies the offset voltage to the space vector pulse width modulation (SVPWM) reference voltage for the same modulation index (MI) as the conventional SVPWM, but any complementary switching operation needs dead time. In addition, the proposed method is divided into four operation sections using the reference voltage and phase current to operate switching devices which flow the current depending on the section. This ZDPWM method is simply implemented by carrier and reference voltage that reduce the current distortion, because complementary operation that needs dead time is not implemented. However, the operation section is delayed due to the sampling delay that occurs during the experiment. Therefore, in this paper, we conduct a modeling of sampling delay to improve the delay of operation section. To verify the principle and feasibility of the proposed ZDPWM method, a simulation and experiment are implemented.
In this paper, a voltage drop compensation method for hybrid hydrogen fuel cell battery system, with a hydrogen recirculation powering a forklift, is studied. During recirculating hydrogen fuel to recycle hydrogen that has not reacted enough at the system, impurities can be mixed with the hydrogen fuel. This leads to low hydrogen concentration and a drop in the output voltage of the fuel cell system. In excessive voltage drop, the fuel cell system can be shutdown. This paper proposes a voltage drop compensation method using an electrical control algorithm to prevent system shutdown by reducing voltage drop. Technically, voltage drop is typically caused by three kinds of factors: (1) The amount of pure hydrogen supply; (2) the temperature of fuel cell stacks; and (3) the current density to catalysts of the fuel cell. The proposed compensation method detects voltage drop caused by those factors, and generates compensation signals for a controller of a DC–DC converter connecting to the output of the fuel cell stack; thus, the voltage drop is reduced by decreasing output current. At the time, insufficient output current to a load is supplied from the batteries. In this paper, voltage drop caused by the abovementioned three factors is analyzed, and the operating principle of the proposed compensation method is specified. To verify this operation and the feasibility of the proposed method, experiments are conducted by applying it to a 10 kW hybrid fuel cell battery system for a forklift.