This paper proposes a novel pulse width modulation (PWM) for a three-level neutral point clamped (NPC) voltage source inverter (VSI). When the conventional PWM method is used in three-level NPC VSI, dead time is required to prevent a short circuit caused by the operation of complementary devices on the upper and lower arms. However, current distortion is increased because of the dead time and it can also cause a voltage unbalance in the dc-link. To solve this problem, we propose a zero dead-time width modulation (ZDPWM) which does not require dead time used in complementary operation. The proposed technique applies the offset voltage to the space vector pulse width modulation (SVPWM) reference voltage for the same modulation index (MI) as the conventional SVPWM, but any complementary switching operation needs dead time. In addition, the proposed method is divided into four operation sections using the reference voltage and phase current to operate switching devices which flow the current depending on the section. This ZDPWM method is simply implemented by carrier and reference voltage that reduce the current distortion, because complementary operation that needs dead time is not implemented. However, the operation section is delayed due to the sampling delay that occurs during the experiment. Therefore, in this paper, we conduct a modeling of sampling delay to improve the delay of operation section. To verify the principle and feasibility of the proposed ZDPWM method, a simulation and experiment are implemented.
Jin-Wook Kang; Seung-Wook Hyun; Yong Kan; Hoon Lee; Jung-Hyo Lee. A Novel Zero Dead-Time PWM Method to Improve the Current Distortion of a Three-Level NPC Inverter. Electronics 2020, 9, 2195 .
AMA StyleJin-Wook Kang, Seung-Wook Hyun, Yong Kan, Hoon Lee, Jung-Hyo Lee. A Novel Zero Dead-Time PWM Method to Improve the Current Distortion of a Three-Level NPC Inverter. Electronics. 2020; 9 (12):2195.
Chicago/Turabian StyleJin-Wook Kang; Seung-Wook Hyun; Yong Kan; Hoon Lee; Jung-Hyo Lee. 2020. "A Novel Zero Dead-Time PWM Method to Improve the Current Distortion of a Three-Level NPC Inverter." Electronics 9, no. 12: 2195.
This paper proposes a permanent magnet synchronous machine (PMSM) table-based torque control method considering a variable DC-link voltage that can be used in a low cost DSP. The current reference generation based on two-dimensional look-up table (2D-LUT) is widely used for PMSM drives used in industrial applications because of its torque control performance and operation stability. In general, a 2D-LUT is established based on the flux and torque to overcome the variation in DC-link voltage. However, this method requires a flux estimator for estimating the instantaneous flux, which is defined as a division of the operating speed used to obtain the flux data. Therefore, to obtain the operating flux, a variable division calculation or complex controller is used, which can be difficult to process through a low cost digital signal processor. In this paper, a novel look-up table-based control method that uses the newly established speed-torque 2D-LUT is proposed. This 2D-LUT inherently implements data on the d-/q-axis currents throughout the operating regions, not only the speed and torque, but also the DC-link voltage variation. The proposed method was verified through an experiment on the torque control a variation in the DC-link voltage.
Do-Yun Kim; Jung-Hyo Lee. Low Cost Simple Look-Up Table-Based PMSM Drive Considering DC-Link Voltage Variation. Energies 2020, 13, 3904 .
AMA StyleDo-Yun Kim, Jung-Hyo Lee. Low Cost Simple Look-Up Table-Based PMSM Drive Considering DC-Link Voltage Variation. Energies. 2020; 13 (15):3904.
Chicago/Turabian StyleDo-Yun Kim; Jung-Hyo Lee. 2020. "Low Cost Simple Look-Up Table-Based PMSM Drive Considering DC-Link Voltage Variation." Energies 13, no. 15: 3904.
This paper illustrates regenerative battery charging control method of the permanent magnet synchronous motor (PMSM) drive without DC/DC converter. Conventional control methods for battery current and voltage control methods generally use a bidirectional DC/DC converter for regenerative control. The reason to use this DC/DC converter is the DC-Link current ripple of the inverter of is affected by switching of the inverter and the motor speed. This problem causes to use a low pass filter (LPF) for sensing the DC-link current, however, it occurs deteriorating the control performance. In this paper, battery current and voltage control methods using only the motor drive are illustrated. To control the DC-link current, power control is performed using the look-up table (LUT) data that are extracted from the experiment. In addition, an applicable method for the variable DC-link voltage of the proposed regenerative control method is illustrated.
Sung-Tae Ko; Soon-Sun Park; Jung-Hyo Lee; Ko; Park; Lee. Regenerative Battery Charging Control Method for PMSM Drive without a DC/DC Converter. Electronics 2019, 8, 1126 .
AMA StyleSung-Tae Ko, Soon-Sun Park, Jung-Hyo Lee, Ko, Park, Lee. Regenerative Battery Charging Control Method for PMSM Drive without a DC/DC Converter. Electronics. 2019; 8 (10):1126.
Chicago/Turabian StyleSung-Tae Ko; Soon-Sun Park; Jung-Hyo Lee; Ko; Park; Lee. 2019. "Regenerative Battery Charging Control Method for PMSM Drive without a DC/DC Converter." Electronics 8, no. 10: 1126.
This study proposes a field weakening control method with interpolation error compensation of the look-up table based permanent-magnet synchronous machine (PMSM) method. The look-up table (LUT) based control method has robust control characteristics compared to other control methods that use linear controllers for current reference generation. However, it is impossible to store all current references under all circumstances for torque commands. General LUT based control methods use two input parameters. In order to mitigate the effect of discretely stored data, two-dimensional interpolation is used to linearly interpolate values between discontinuous data. However, because the current trajectories of PMSMs are generally ellipsoidal, an error occurs between the linearly interpolated and controllable current references. This study proposes a method to compensate for this interpolation error using a feedforward controller for rapid compensation. The improvement using the proposed method is verified by experiment and simulation.
Young-Bae Ji; Jung-Hyo Lee; Ji; Lee. Feedforward Interpolation Error Compensation Method for Field Weakening Operation Region of PMSM Drive. Electronics 2019, 8, 1052 .
AMA StyleYoung-Bae Ji, Jung-Hyo Lee, Ji, Lee. Feedforward Interpolation Error Compensation Method for Field Weakening Operation Region of PMSM Drive. Electronics. 2019; 8 (9):1052.
Chicago/Turabian StyleYoung-Bae Ji; Jung-Hyo Lee; Ji; Lee. 2019. "Feedforward Interpolation Error Compensation Method for Field Weakening Operation Region of PMSM Drive." Electronics 8, no. 9: 1052.
This paper proposes field weakening control method of the look-up table based permanent magnet synchronous machine (PMSM) with interpolation error compensation. The look-up table based control method has robust control characteristic than other control methods which use linear controller for current reference generation. However, it is impossible to store all current references under all circumstances for torque commands. General look-up table based control method using two input parameters, in order to mitigate the effect of discretely stored data, two-dimension-interpolation method (2D-Interpolation) is used for linear interpolating between discontinuous data. However, due to the current trajectories of PMSM are generally ellipsoidal, the error is occurred between linearly interpolated and controllable current references. This paper proposes a method to compensate this interpolation error using feedforward controller for fast compensation. The improvement of proposed method is verified by experiment and simulation.
Jung-Hyo Lee. DC-link voltage feedforwarded interpolation error compensation method for field weakening operation region of look-up table based PMSM drive. IOP Conference Series: Materials Science and Engineering 2019, 600, 012024 .
AMA StyleJung-Hyo Lee. DC-link voltage feedforwarded interpolation error compensation method for field weakening operation region of look-up table based PMSM drive. IOP Conference Series: Materials Science and Engineering. 2019; 600 (1):012024.
Chicago/Turabian StyleJung-Hyo Lee. 2019. "DC-link voltage feedforwarded interpolation error compensation method for field weakening operation region of look-up table based PMSM drive." IOP Conference Series: Materials Science and Engineering 600, no. 1: 012024.
In this paper, a voltage drop compensation method for hybrid hydrogen fuel cell battery system, with a hydrogen recirculation powering a forklift, is studied. During recirculating hydrogen fuel to recycle hydrogen that has not reacted enough at the system, impurities can be mixed with the hydrogen fuel. This leads to low hydrogen concentration and a drop in the output voltage of the fuel cell system. In excessive voltage drop, the fuel cell system can be shutdown. This paper proposes a voltage drop compensation method using an electrical control algorithm to prevent system shutdown by reducing voltage drop. Technically, voltage drop is typically caused by three kinds of factors: (1) The amount of pure hydrogen supply; (2) the temperature of fuel cell stacks; and (3) the current density to catalysts of the fuel cell. The proposed compensation method detects voltage drop caused by those factors, and generates compensation signals for a controller of a DC–DC converter connecting to the output of the fuel cell stack; thus, the voltage drop is reduced by decreasing output current. At the time, insufficient output current to a load is supplied from the batteries. In this paper, voltage drop caused by the abovementioned three factors is analyzed, and the operating principle of the proposed compensation method is specified. To verify this operation and the feasibility of the proposed method, experiments are conducted by applying it to a 10 kW hybrid fuel cell battery system for a forklift.
Tae-Ho Eom; Jin-Wook Kang; Jintae Kim; Min-Ho Shin; Jung-Hyo Lee; Chung-Yuen Won. Improved Voltage Drop Compensation Method for Hybrid Fuel Cell Battery System. Electronics 2018, 7, 331 .
AMA StyleTae-Ho Eom, Jin-Wook Kang, Jintae Kim, Min-Ho Shin, Jung-Hyo Lee, Chung-Yuen Won. Improved Voltage Drop Compensation Method for Hybrid Fuel Cell Battery System. Electronics. 2018; 7 (11):331.
Chicago/Turabian StyleTae-Ho Eom; Jin-Wook Kang; Jintae Kim; Min-Ho Shin; Jung-Hyo Lee; Chung-Yuen Won. 2018. "Improved Voltage Drop Compensation Method for Hybrid Fuel Cell Battery System." Electronics 7, no. 11: 331.
Young-Sang Ko; Kyung-Min Kang; Jin-Wook Kang; Jung-Hyo Lee; Chung-Yuen Won. Dual Battery Pack Charge/Discharge System for ESS using 3-Level NPC AC/DC PWM Converter. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2018, 32, 24 -32.
AMA StyleYoung-Sang Ko, Kyung-Min Kang, Jin-Wook Kang, Jung-Hyo Lee, Chung-Yuen Won. Dual Battery Pack Charge/Discharge System for ESS using 3-Level NPC AC/DC PWM Converter. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers. 2018; 32 (10):24-32.
Chicago/Turabian StyleYoung-Sang Ko; Kyung-Min Kang; Jin-Wook Kang; Jung-Hyo Lee; Chung-Yuen Won. 2018. "Dual Battery Pack Charge/Discharge System for ESS using 3-Level NPC AC/DC PWM Converter." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 32, no. 10: 24-32.
This paper proposes a position control method for a low-cost exhaust gas recirculation (EGR) valve system for automotive applications. Generally, position control systems used in automotive applications have many restrictions, such as cost and space. The mechanical structure of the actuator causes high friction and large differences between static friction and coulomb friction. When this large friction difference occurs, the position control vibrates when the controller uses a conventional linear controller such as the P or PI controller. In this paper, we introduce an inexpensive position control method that can be applied under the high-difference-friction mechanical systems. The proposed method is verified through the use of experiments by comparing it with the results obtained when using a conventional control system.
Habib Bhuiyan; Jung-Hyo Lee. Low Cost Position Controller for Exhaust Gas Recirculation Valve System. Energies 2018, 11, 2171 .
AMA StyleHabib Bhuiyan, Jung-Hyo Lee. Low Cost Position Controller for Exhaust Gas Recirculation Valve System. Energies. 2018; 11 (8):2171.
Chicago/Turabian StyleHabib Bhuiyan; Jung-Hyo Lee. 2018. "Low Cost Position Controller for Exhaust Gas Recirculation Valve System." Energies 11, no. 8: 2171.
Tae-Ho Eom; Jun-Mo Kim; Jeong Lee; Sung-Mun Jeong; Min-Ho Shin; Jung-Hyo Lee; Chung-Yuen Won. Fuel Cell Simulator considering Hydrogen Recirculation Characteristics. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2018, 32, 8 -19.
AMA StyleTae-Ho Eom, Jun-Mo Kim, Jeong Lee, Sung-Mun Jeong, Min-Ho Shin, Jung-Hyo Lee, Chung-Yuen Won. Fuel Cell Simulator considering Hydrogen Recirculation Characteristics. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers. 2018; 32 (7):8-19.
Chicago/Turabian StyleTae-Ho Eom; Jun-Mo Kim; Jeong Lee; Sung-Mun Jeong; Min-Ho Shin; Jung-Hyo Lee; Chung-Yuen Won. 2018. "Fuel Cell Simulator considering Hydrogen Recirculation Characteristics." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 32, no. 7: 8-19.
In a DC distribution system configured by AC/DC power conversion system (PCS), the voltage control performance of the AC/DC PCS determines the stability and reliability of the DC distribution grid. The DC voltage of grid is maintained by capacitor, thus transient voltage is an inevitable problem when a grid is connected with a high amount of load or renewable energy. Space vector pulse width modulation (SVPWM) is well known as a stable modulation method and is used in AC/DC PCS and many types of topologies, but a solution for the transient states issue of DC link has not clearly been studied. In this paper, a feedforward compensation method based on the mathematical model of SVPWM is proposed to solve the transient state problem in a DC distribution system. The proposed method is verified by simulation and experiment. AC/DC PCS with the proposed feedforward compensation method has more robust DC voltage control characteristics.
Seok-Jin Hong; Seung-Wook Hyun; Kyung-Min Kang; Jung-Hyo Lee; Chung-Yuen Won. Improvement of Transient State Response through Feedforward Compensation Method of AC/DC Power Conversion System (PCS) Based on Space Vector Pulse Width Modulation (SVPWM). Energies 2018, 11, 1468 .
AMA StyleSeok-Jin Hong, Seung-Wook Hyun, Kyung-Min Kang, Jung-Hyo Lee, Chung-Yuen Won. Improvement of Transient State Response through Feedforward Compensation Method of AC/DC Power Conversion System (PCS) Based on Space Vector Pulse Width Modulation (SVPWM). Energies. 2018; 11 (6):1468.
Chicago/Turabian StyleSeok-Jin Hong; Seung-Wook Hyun; Kyung-Min Kang; Jung-Hyo Lee; Chung-Yuen Won. 2018. "Improvement of Transient State Response through Feedforward Compensation Method of AC/DC Power Conversion System (PCS) Based on Space Vector Pulse Width Modulation (SVPWM)." Energies 11, no. 6: 1468.
Ohsuk Kwon; Jungkyun Seo; Jung-Hyo Lee. Low Cost Fast Response Position Controller for Valve System in Automotive Application. Proceedings of The 6th IIAE International Conference on Industrial Application Engineering 2018 2018, 1 .
AMA StyleOhsuk Kwon, Jungkyun Seo, Jung-Hyo Lee. Low Cost Fast Response Position Controller for Valve System in Automotive Application. Proceedings of The 6th IIAE International Conference on Industrial Application Engineering 2018. 2018; ():1.
Chicago/Turabian StyleOhsuk Kwon; Jungkyun Seo; Jung-Hyo Lee. 2018. "Low Cost Fast Response Position Controller for Valve System in Automotive Application." Proceedings of The 6th IIAE International Conference on Industrial Application Engineering 2018 , no. : 1.
This paper proposes paralleled structure of LDC for an electrical vehicle, unlike conventional integral structure, paralleled structure of LDC controls each module of battery independently to solve the temperature unbalance problem among each module during discharging period. Temperature balance control between modules was performed by controlling the amount of discharging current for its corresponding temperature of each module of HVBAT, and temperature fluctuation was confirmed through a thermal camera. Data was collected by experiment about characteristic fluctuation of a battery according to temperature and validity of proposed control method is also proved by experiment.
Min-Ho Shin; Tae-Ho Eom; Jun-Mo Kim; Jeong Lee; Sung-Hoon Kim; Yong-Seok Lee; Jung-Hyo Lee; Chung-Yuen Won. Discharge Control Method of Paralleled LDC System considering Battery Temperature. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2017, 31, 77 -83.
AMA StyleMin-Ho Shin, Tae-Ho Eom, Jun-Mo Kim, Jeong Lee, Sung-Hoon Kim, Yong-Seok Lee, Jung-Hyo Lee, Chung-Yuen Won. Discharge Control Method of Paralleled LDC System considering Battery Temperature. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers. 2017; 31 (3):77-83.
Chicago/Turabian StyleMin-Ho Shin; Tae-Ho Eom; Jun-Mo Kim; Jeong Lee; Sung-Hoon Kim; Yong-Seok Lee; Jung-Hyo Lee; Chung-Yuen Won. 2017. "Discharge Control Method of Paralleled LDC System considering Battery Temperature." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 31, no. 3: 77-83.
A Method to Compensate the Distorted Space Vectors in the Unbalanced Neutral Point Voltage of 3-level NPC PWM Inverters Neutral point voltage;NPC inverter;Space vector;Unbalance; This paper proposes a compensation method to improve the distorted space vectors when a 3-level Neutral Point Clamped (NPC) inverter has an unbalanced neutral point voltage. Since both the neutral point voltage of the DC link and the space vector of a 3-level NPC inverter are closely related depending on the output load connecting state, a distorted space vector can occur when the neutral point voltage of a 3-level NPC inverter is unbalanced. The proposed method can improve the distorted space vectors by adjusting the injection time of the small and medium vectors and by modulating the amplitude of the carrier waveforms. In this paper, the proposed method is verified by both simulation and experimental results based on a 3-level NPC inverter.
Seung-Wook Hyun; Seok-Jin Hong; Jung-Hyo Lee; Chun-Bok Lee; Chung-Yuen Won. A Method to Compensate the Distorted Space Vectors in the Unbalanced Neutral Point Voltage of 3-level NPC PWM Inverters. Journal of Power Electronics 2016, 16, 455 -463.
AMA StyleSeung-Wook Hyun, Seok-Jin Hong, Jung-Hyo Lee, Chun-Bok Lee, Chung-Yuen Won. A Method to Compensate the Distorted Space Vectors in the Unbalanced Neutral Point Voltage of 3-level NPC PWM Inverters. Journal of Power Electronics. 2016; 16 (2):455-463.
Chicago/Turabian StyleSeung-Wook Hyun; Seok-Jin Hong; Jung-Hyo Lee; Chun-Bok Lee; Chung-Yuen Won. 2016. "A Method to Compensate the Distorted Space Vectors in the Unbalanced Neutral Point Voltage of 3-level NPC PWM Inverters." Journal of Power Electronics 16, no. 2: 455-463.
Seung-Wook Hyun; Jung-Hyo Lee; Chung-Yuen Won. Convenient Thermal Modeling for Loss Distribution method of 3-Level Active NPC Inverter using Newton's Law of cooling. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2015, 29, 71 -80.
AMA StyleSeung-Wook Hyun, Jung-Hyo Lee, Chung-Yuen Won. Convenient Thermal Modeling for Loss Distribution method of 3-Level Active NPC Inverter using Newton's Law of cooling. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers. 2015; 29 (9):71-80.
Chicago/Turabian StyleSeung-Wook Hyun; Jung-Hyo Lee; Chung-Yuen Won. 2015. "Convenient Thermal Modeling for Loss Distribution method of 3-Level Active NPC Inverter using Newton's Law of cooling." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 29, no. 9: 71-80.
Jung-Hyo Lee; Chung-Yuen Won. An Efficient Battery Charging Algorithm based on State-of-Charge Estimation using 3-Phase AC-DC Boost Converter. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2015, 29, 96 -102.
AMA StyleJung-Hyo Lee, Chung-Yuen Won. An Efficient Battery Charging Algorithm based on State-of-Charge Estimation using 3-Phase AC-DC Boost Converter. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers. 2015; 29 (9):96-102.
Chicago/Turabian StyleJung-Hyo Lee; Chung-Yuen Won. 2015. "An Efficient Battery Charging Algorithm based on State-of-Charge Estimation using 3-Phase AC-DC Boost Converter." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 29, no. 9: 96-102.
Dong-Kyun Ryu; Hee-Jun Lee; Jung-Hyo Lee; Chung-Yuen Won. Control and Design of a Arc Power Supply for KSTAR's the Neutral Beam Injection. Journal of Electrical Engineering & Technology 2015, 10, 216 -226.
AMA StyleDong-Kyun Ryu, Hee-Jun Lee, Jung-Hyo Lee, Chung-Yuen Won. Control and Design of a Arc Power Supply for KSTAR's the Neutral Beam Injection. Journal of Electrical Engineering & Technology. 2015; 10 (1):216-226.
Chicago/Turabian StyleDong-Kyun Ryu; Hee-Jun Lee; Jung-Hyo Lee; Chung-Yuen Won. 2015. "Control and Design of a Arc Power Supply for KSTAR's the Neutral Beam Injection." Journal of Electrical Engineering & Technology 10, no. 1: 216-226.
Sang-Suk Lee; Soon-Ryung Lee; Bong-Yeon Choi; Jung-Hyo Lee; Chung-Yuen Won. Mode Transfer Sequence and Control of Single-phase UPS System. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2014, 28, 108 -115.
AMA StyleSang-Suk Lee, Soon-Ryung Lee, Bong-Yeon Choi, Jung-Hyo Lee, Chung-Yuen Won. Mode Transfer Sequence and Control of Single-phase UPS System. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers. 2014; 28 (12):108-115.
Chicago/Turabian StyleSang-Suk Lee; Soon-Ryung Lee; Bong-Yeon Choi; Jung-Hyo Lee; Chung-Yuen Won. 2014. "Mode Transfer Sequence and Control of Single-phase UPS System." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 28, no. 12: 108-115.
An-Yeol Ko; Do-Yun Kim; Jung-Hyo Lee; Young-Real Kim; Chung-Yuen Won. Reduction of Current Distortion in PWM Inverter by Variable DC-link Voltage of DC-DC Converter for FCEV. The Transactions of the Korean Institute of Power Electronics 2014, 19, 572 -581.
AMA StyleAn-Yeol Ko, Do-Yun Kim, Jung-Hyo Lee, Young-Real Kim, Chung-Yuen Won. Reduction of Current Distortion in PWM Inverter by Variable DC-link Voltage of DC-DC Converter for FCEV. The Transactions of the Korean Institute of Power Electronics. 2014; 19 (6):572-581.
Chicago/Turabian StyleAn-Yeol Ko; Do-Yun Kim; Jung-Hyo Lee; Young-Real Kim; Chung-Yuen Won. 2014. "Reduction of Current Distortion in PWM Inverter by Variable DC-link Voltage of DC-DC Converter for FCEV." The Transactions of the Korean Institute of Power Electronics 19, no. 6: 572-581.
Jung-Hyo Lee; Chung-Yuen Won. A Performance Improvement Method of PMSM Torque Control Considering DC-link Voltage Variation. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2014, 28, 112 -122.
AMA StyleJung-Hyo Lee, Chung-Yuen Won. A Performance Improvement Method of PMSM Torque Control Considering DC-link Voltage Variation. Journal of the Korean Institute of Illuminating and Electrical Installation Engineers. 2014; 28 (11):112-122.
Chicago/Turabian StyleJung-Hyo Lee; Chung-Yuen Won. 2014. "A Performance Improvement Method of PMSM Torque Control Considering DC-link Voltage Variation." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 28, no. 11: 112-122.
Hee-Jun Lee; Soo-Cheol Shin; Seok-Jin Hong; Seung-Wook Hyun; Jung-Hyo Lee; Chung-Yuen Won. Performance Improvement of Isolated High Voltage Full Bridge Converter Using Voltage Doubler. Journal of Electrical Engineering & Technology 2014, 9, 2224 -2236.
AMA StyleHee-Jun Lee, Soo-Cheol Shin, Seok-Jin Hong, Seung-Wook Hyun, Jung-Hyo Lee, Chung-Yuen Won. Performance Improvement of Isolated High Voltage Full Bridge Converter Using Voltage Doubler. Journal of Electrical Engineering & Technology. 2014; 9 (6):2224-2236.
Chicago/Turabian StyleHee-Jun Lee; Soo-Cheol Shin; Seok-Jin Hong; Seung-Wook Hyun; Jung-Hyo Lee; Chung-Yuen Won. 2014. "Performance Improvement of Isolated High Voltage Full Bridge Converter Using Voltage Doubler." Journal of Electrical Engineering & Technology 9, no. 6: 2224-2236.