View All Publications
31 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
DKDo-Yun Kim
Do-Yun Kim
JLJung-Hyo Lee
Jung-Hyo Lee
This paper proposes a permanent magnet synchronous machine (PMSM) table-based torque control method considering a variable DC-link voltage that can be used in a low cost DSP. The current reference generation based on two-dimensional look-up table (2D-LUT) is widely used for PMSM drives used in industrial applications because of its torque control performance and operation stability. In general, a 2D-LUT is established based on the flux and torque to overcome the variation in DC-link voltage. However, this method requires a flux estimator for estimating the instantaneous flux, which is defined as a division of the operating speed used to obtain the flux data. Therefore, to obtain the operating flux, a variable division calculation or complex controller is used, which can be difficult to process through a low cost digital signal processor. In this paper, a novel look-up table-based control method that uses the newly established speed-torque 2D-LUT is proposed. This 2D-LUT inherently implements data on the d-/q-axis currents throughout the operating regions, not only the speed and torque, but also the DC-link voltage variation. The proposed method was verified through an experiment on the torque control a variation in the DC-link voltage.

4 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
DKDo-Yun Kim
Do-Yun Kim
JLJung-Hyo Lee
Jung-Hyo Lee
This paper proposes a compensation method for interpolation error of the maximum power control of a PMSM control system that generates current commands through a look-up table. A torque control system using a look-up table created through experiments has superior characteristics, such as control stability and torque accuracy, compared to a system that executes torque control via a linear controller based on modeling. However, it is impossible to generate information on all the currents for the output torque in the table. Therefore, because the data stored in the look-up table have a discrete characteristic, they are linearly interpolated to generate a current command for the torque command. However, the PMSM current trajectory is generally elliptical, which causes an error owing to linear interpolation, reducing the maximum output power. In particular, when the table data are insufficient, such as in the high-speed operation range, the reduced maximum output cannot be ignored. This paper proposes a compensation method for the interpolation error using two feedforward compensators and a PI controller, which was verified through experiments.

19 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
JKJin-Wook Kang
Jin-Wook Kang
SHSeung-Wook Hyun
Seung-Wook Hyun
YKYong Kan
Yong Kan
HLHoon Lee
Hoon Lee
JLJung-Hyo Lee
Jung-Hyo Lee
This paper proposes a novel pulse width modulation (PWM) for a three-level neutral point clamped (NPC) voltage source inverter (VSI). When the conventional PWM method is used in three-level NPC VSI, dead time is required to prevent a short circuit caused by the operation of complementary devices on the upper and lower arms. However, current distortion is increased because of the dead time and it can also cause a voltage unbalance in the dc-link. To solve this problem, we propose a zero dead-time width modulation (ZDPWM) which does not require dead time used in complementary operation. The proposed technique applies the offset voltage to the space vector pulse width modulation (SVPWM) reference voltage for the same modulation index (MI) as the conventional SVPWM, but any complementary switching operation needs dead time. In addition, the proposed method is divided into four operation sections using the reference voltage and phase current to operate switching devices which flow the current depending on the section. This ZDPWM method is simply implemented by carrier and reference voltage that reduce the current distortion, because complementary operation that needs dead time is not implemented. However, the operation section is delayed due to the sampling delay that occurs during the experiment. Therefore, in this paper, we conduct a modeling of sampling delay to improve the delay of operation section. To verify the principle and feasibility of the proposed ZDPWM method, a simulation and experiment are implemented.

31 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
WJWon-Sang Jeong
Won-Sang Jeong
YLYoon-Seong Lee
Yoon-Seong Lee
JLJung-Hyo Lee
Jung-Hyo Lee
CLChang-Hee Lee
Chang-Hee Lee
CWChung-Yuen Won
Chung-Yuen Won
This paper proposes a space vector modulation (SVM)-based common-mode (CM) currents reduction method of an H8 inverter for permanent magnet synchronous motor (PMSM) drives. There are power quality issues in the PMSM drive systems, such as current distortions and CM electromagnetic interference (EMI) due to the fast-switching operation of the inverter. These issues are related to CM voltage (CMV) and CM current (CMC). Although several studies have been conducted to reduce the CMV and CMC, some CMV variations and CMCs are still generated in the real implementation. Unlike conventional methods, the proposed method selects the voltage vectors with similar CMV levels and arranges them considering the series-connected switch operation of the H8 inverter in a voltage vector modulation sequence. At a low modulation index (MI), the proposed method completely restricts the CMV variations into six times. At high MI, the proposed method synthesizes the reference voltage vector differently, depending on the position of the reference vector, to reduce both current distortions and CMCs. The validity of the proposed method is verified through simulations and experimental results.

18 September 2019 in Electronics
Verified
Journal Article
Open access
PDF file
YJYoung-Bae Ji
Young-Bae Ji
JLJung-Hyo Lee
Jung-Hyo Lee
This study proposes a field weakening control method with interpolation error compensation of the look-up table based permanent-magnet synchronous machine (PMSM) method. The look-up table (LUT) based control method has robust control characteristics compared to other control methods that use linear controllers for current reference generation. However, it is impossible to store all current references under all circumstances for torque commands. General LUT based control methods use two input parameters. In order to mitigate the effect of discretely stored data, two-dimensional interpolation is used to linearly interpolate values between discontinuous data. However, because the current trajectories of PMSMs are generally ellipsoidal, an error occurs between the linearly interpolated and controllable current references. This study proposes a method to compensate for this interpolation error using a feedforward controller for rapid compensation. The improvement using the proposed method is verified by experiment and simulation.

17 November 2018 in Electronics
Verified
Journal Article
Open access
PDF file
TETae-Ho Eom
Tae-Ho Eom
JKJin-Wook Kang
Jin-Wook Kang
JKJintae Kim
Jintae Kim
MSMin-Ho Shin
Min-Ho Shin
JLJung-Hyo Lee
Jung-Hyo Lee
CWChung-Yuen Won
Chung-Yuen Won
In this paper, a voltage drop compensation method for hybrid hydrogen fuel cell battery system, with a hydrogen recirculation powering a forklift, is studied. During recirculating hydrogen fuel to recycle hydrogen that has not reacted enough at the system, impurities can be mixed with the hydrogen fuel. This leads to low hydrogen concentration and a drop in the output voltage of the fuel cell system. In excessive voltage drop, the fuel cell system can be shutdown. This paper proposes a voltage drop compensation method using an electrical control algorithm to prevent system shutdown by reducing voltage drop. Technically, voltage drop is typically caused by three kinds of factors: (1) The amount of pure hydrogen supply; (2) the temperature of fuel cell stacks; and (3) the current density to catalysts of the fuel cell. The proposed compensation method detects voltage drop caused by those factors, and generates compensation signals for a controller of a DC–DC converter connecting to the output of the fuel cell stack; thus, the voltage drop is reduced by decreasing output current. At the time, insufficient output current to a load is supplied from the batteries. In this paper, voltage drop caused by the abovementioned three factors is analyzed, and the operating principle of the proposed compensation method is specified. To verify this operation and the feasibility of the proposed method, experiments are conducted by applying it to a 10 kW hybrid fuel cell battery system for a forklift.