Chung-Yuen Won

Prof. Chung-Yuen Won

Department of Electrical and Computer Engineering, SungKyunKwan Univ., Suwon, Gyeonggi, Republic of Korea

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
MKMIN SUNG KIM
MIN SUNG KIM
RHRAZA HAIDER
RAZA HAIDER
GCGyu-Jung Cho
Gyu-Jung Cho
CKChul-Hwan Kim
Chul-Hwan Kim
CWChung-Yuen Won
Chung-Yuen Won
JCJong-Seo Chai
Jong-Seo Chai
The increased penetration of distributed generation (DG), renewable energy utilization, and the introduction of the microgrid concept have changed the shape of conventional electric power networks. Most of the new power system networks are transforming into the DG model integrated with renewable and non-renewable energy resources by forming a microgrid. Islanding detection in DG systems is a challenging issue that causes several protection and safety problems. A microgrid operates in the grid-connected or stand-alone mode. In the grid-connected mode, the main utility network is responsible for a smooth operation in coordination with the protection and control units, while in the stand-alone mode, the microgrid operates as an independent power island that is electrically separated from the main utility network. Fast islanding detection is, therefore, necessary for efficient and reliable microgrid operations. Many islanding detection methods (IdMs) are proposed in the literature, and each of them claims better reliability and high accuracy. This study describes a comprehensive review of various IdMs in terms of their merits, viability, effectiveness, and feasibility. The IdMs are extensively analysed by providing a fair comparison from different aspects. Moreover, a fair analysis of a feasible and economical solution in view of the recent research trend is presented.

14 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KCKyoung-Min Choo
Kyoung-Min Choo
CWChung-Yuen Won
Chung-Yuen Won
In this paper, an electrical braking torque limit trajectory is designed to improve the regenerative braking of electric vehicles based on a regenerative power analysis. Even though electric motors generally regenerate electric energy from kinetic energy, the drive system dissipates electric energy under certain low-speed operation conditions. This phenomenon has been addressed in many previous works and most of them compensate for this power dissipation region by modifying the electrical braking torque limit trajectory of the motor. However, the torque limit trajectory has never been considered based on a regenerative power analysis even though an inaccurate torque limit trajectory causes energy loss to the drive system. In this paper, the regenerative power analysis for two major kinds of permanent magnet synchronous motor is performed. Afterward, torque limit trajectories are set based on this analysis so that batteries in electric vehicles can harvest the maximum regenerative energy in any circumstance. To verify the analysis and proposed torque limit trajectories, simulations and experiments are performed.

9 August 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JKJintae Kim
Jintae Kim
HCHangseok Choi
Hangseok Choi
CWChung-Yuen Won
Chung-Yuen Won
A new modulated carrier control (MCC) method is proposed in this paper for power factor correction (PFC) boost converter which provides high power factor (PF) and low total harmonic distortion (THD) in wide input voltage and load range. The proposed MCC method employs a zero current duration (ZCD) demodulator that detects ZCD in each switching cycle to estimate current conduction duration of the boost inductor. Using the estimated signal of the ZCD demodulator, the proposed controller generates a compensated duty signal with a PFC converter to properly operate in continuous conduction mode (CCM) or discontinuous conduction mode (DCM).

2 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
JLJeong Lee
Jeong Lee
KJKIM JUN-MO
KIM JUN-MO
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
Aging increases the internal resistance of a battery and reduces its capacity; therefore, energy storage systems (ESSs) require a battery management system (BMS) algorithm that can manage the state of the battery. This paper proposes a battery efficiency calculation formula to manage the battery state. The proposed battery efficiency calculation formula uses the charging time, charging current, and battery capacity. An algorithm that can accurately determine the battery state is proposed by applying the proposed state of charge (SoC) and state of health (SoH) calculations. To reduce the initial error of the Coulomb counting method (CCM), the SoC can be calculated accurately by applying the battery efficiency to the open circuit voltage (OCV). During the charging and discharging process, the internal resistance of a battery increase and the constant current (CC) charging time decrease. The SoH can be predicted from the CC charging time of the battery and the battery efficiency, as proposed in this paper. Furthermore, a safe system is implemented during charging and discharging by applying a fault diagnosis algorithm to reduce the battery efficiency. The validity of the proposed BMS algorithm is demonstrated by applying it in a 3-kW ESS.

11 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
KKKang Kyungmin
Kang Kyungmin
BCBong-Yeon Choi
Bong-Yeon Choi
HLHoon Lee
Hoon Lee
CAChang-Gyun An
Chang-Gyun An
TKTae-Gyu Kim
Tae-Gyu Kim
CWChung-Yuen Won
Chung-Yuen Won
This paper proposes an artificial neural network (ANN)-based energy management system (EMS) for controlling power in AC–DC hybrid distribution networks. The proposed ANN-based EMS selects an optimal operating mode by collecting data such as the power provided by distributed generation (DG), the load demand, and state of charge (SOC). For training the ANN, profile data on the charging and discharging amount of ESS for various distribution network power situations were prepared, and the ANN was trained with an error rate within 10%. The proposed EMS controls each power converter in the optimal operation mode through the already trained ANN in the grid-connected mode. For the experimental verification of the proposed EMS, a small-scale hybrid AD/DC microgrid was fabricated, and simulations and experiments were performed for each operation mode.

14 October 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SKSung-Hun Kim
Sung-Hun Kim
HBHyung-Jun Byun
Hyung-Jun Byun
WJWon-Sang Jeong
Won-Sang Jeong
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
Bipolar dc microgrid (MG) based on two voltage levels with three wires has higher reliability and flexibility than unipolar dc MG. However, the voltages of bipolar buses are coupled and the voltage of the PN bus affects the voltages of the bipolar buses in bipolar dc MG. In this article, a hierarchical control with voltage balancing and energy management based on the characteristics of bipolar dc MG is proposed. To perform distributed power sharing with coupled voltages, droop-based primary controls for three buses and the coupling relationships between three buses are analyzed. Furthermore, in secondary control, balancing and voltage restoration controls are proposed to compensate for voltage drops caused by the balanced and unbalanced loads. To design the proposed hierarchical control, the stability analysis is performed. Additionally, a tertiary control based on an artificial neural network is proposed for state-of-charge management of bipolar dc MG. Experimental results of the proposed hierarchical control are verified by a lab-scale bipolar dc MG and performance analysis is performed with experimental and ideal results.