Ryoichi Ohta

Dr. Ryoichi Ohta

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
KMKyojiro Morikawa
Kyojiro Morikawa
RORyoichi Ohta
Ryoichi Ohta
KMKazuma Mawatari
Kazuma Mawatari
TKTakehiko Kitamori
Takehiko Kitamori
In microfluidics, especially in nanofluidics, nanochannels with functionalized surfaces have recently attracted attention for use as a new tool for the investigation of chemical reaction fields. Molecules handled in the reaction field can reach the single–molecule level due to the small size of the nanochannel. In such surroundings, contamination of the channel surface should be removed at the single–molecule level. In this study, it was assumed that metal materials could contaminate the nanochannels during the fabrication processes; therefore, we aimed to develop metal-free fabrication processes. Fused silica channels 1000 nm-deep were conventionally fabricated using a chromium mask. Instead of chromium, electron beam resists more than 1000 nm thick were used and the lithography conditions were optimized. From the results of optimization, channels with 1000 nm scale width and depth were fabricated on fused silica substrates without the use of a chromium mask. In nanofluidic experiments, an oxidation reaction was observed in a device fabricated by conventional fabrication processes using a chromium mask. It was found that Cr6+ remained on the channel surfaces and reacted with chemicals in the liquid phase in the extended nanochannels; this effect occurred at least to the micromolar level. In contrast, the device fabricated with metal-free processes was free of artifacts induced by the presence of chromium. The developed fabrication processes and results of this study will be a significant contribution to the fundamental technologies employed in the fields of microfluidics and nanofluidics.

7 December 2023 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Open access
PDF file
RORyoichi Ohta
Ryoichi Ohta
KMKyojiro Morikawa
Kyojiro Morikawa
YTYoshiyuki Tsuyama
Yoshiyuki Tsuyama
TKTakehiko Kitamori
Takehiko Kitamori
The bonding of glass substrates is an important process in the fabrication of glass micro/nanofluidic devices. In this study, the influence of the surface roughness of glass substrates after low-temperature bonding is investigated. It is found that plasma etching can be used to control the surface roughness to the range 2–9 nm. Substrates with a roughness of 5 nm or less can be bonded. The pressure capacity of devices tends to decrease with increasing surface roughness. A pressure capacity of 500 kPa or higher is obtained with a surface roughness of 2 nm or less. This criterion for bonding conditions can be applied to roughness formed by other methods (e.g. via a Cr layer). The proposed approach will facilitate the design and fabrication of glass micro/nanofluidic devices, especially those that complicated fabrication processes or embedding of multiple materials.

6 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
KMKyojiro Morikawa
Kyojiro Morikawa
HKHaruki Kazumi
Haruki Kazumi
YTYoshiyuki Tsuyama
Yoshiyuki Tsuyama
RORyoichi Ohta
Ryoichi Ohta
TKTakehiko Kitamori
Takehiko Kitamori
In nanofluidics, surface control is a critical technology because nanospaces are surface-governed spaces as a consequence of their extremely high surface-to-volume ratio. Various surface patterning methods have been developed, including patterning on an open substrate and patterning using a liquid modifier in microchannels. However, the surface patterning of a closed nanochannel is difficult. In addition, the surface evaluation of closed nanochannels is difficult because of a lack of appropriate experimental tools. In this study, we verified the surface patterning of a closed nanochannel by vacuum ultraviolet (VUV) light and evaluated the surface using streaming-current measurements. First, the C18 modification of closed nanochannels was confirmed by Laplace pressure measurements. In addition, no streaming-current signal was detected for the C18-modified surface, confirming the successful modification of the nanochannel surface with C18 groups. The C18 groups were subsequently decomposed by VUV light, and the nanochannel surface became hydrophilic because of the presence of silanol groups. In streaming-current measurements, the current signals increased in amplitude with increasing VUV light irradiation time, indicating the decomposition of the C18 groups on the closed nanochannel surfaces. Finally, hydrophilic/hydrophobic patterning by VUV light was performed in a nanochannel. Capillary filling experiments confirmed the presence of a hydrophilic/hydrophobic interface. Therefore, VUV patterning in a closed nanochannel was demonstrated, and the surface of a closed nanochannel was successfully evaluated using streaming-current measurements.

30 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
TLThu H. H. Le
Thu H. H. Le
TMTakumi Matsushita
Takumi Matsushita
RORyoichi Ohta
Ryoichi Ohta
YSYuta Shimoda
Yuta Shimoda
HMHiroaki Matsui
Hiroaki Matsui
TKTakehiko Kitamori
Takehiko Kitamori
Nanofluidic devices have offered us fascinating analytical platforms for chemical and bioanalysis by exploiting unique properties of liquids and molecules confined in nanospaces. The increasing interests in nanofluidic analytical devices have triggered the development of new robust and sensitive detection techniques, especially label-free ones. IR absorption spectroscopy is one of the most powerful biochemical analysis methods for identification and quantitative measurement of chemical species in the label-free and non-invasive fashion. However, the low sensitivity and the difficulties in fabrication of IR-compatible nanofluidic devices are major obstacles that restrict the applications of IR spectroscopy in nanofluidics. Here, we realized the bonding of CaF2 and SiO2 at room temperature and demonstrated an IR-compatible nanofluidic device that allowed the IR spectroscopy in a wide range of mid-IR regime. We also performed the integration of metal-insulator-metal perfect absorber metamaterials into nanofluidic devices for plasmon-enhanced infrared absorption spectroscopy with ultrahigh sensitivity. This study also shows a proof-of-concept of the multi-band absorber by combining different types of nanostructures. The results indicate the potential of implementing metamaterials in tracking several characteristic molecular vibrational modes simultaneously, making it possible to identify molecular species in mixture or complex biological entities.

3 April 2026 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
RORyoichi Ohta
Ryoichi Ohta
ZZZhixin Zhao
Zhixin Zhao
XYXuan Yan
Xuan Yan
RWRuying Wang
Ruying Wang
KMKazuma Mawatari
Kazuma Mawatari
Liquid–liquid phase separation (LLPS) functions as a high-performance reactor strategy in cells, creating dynamic "membrane-less organelles" that selectively concentrate biomolecules. Mimicking this volumetric strategy on a chip offers a route to transcend the capacity and kinetic limits of conventional static surface functionalization; however, engineering applications have been hindered by the stochastic nature of condensate nucleation in bulk mixing. Here, we present "Flow-programmable nanofluidic surface LLPS," a method for deterministically and instantaneously inducing and manipulating surface-mediated LLPS condensates by utilizing the high surface area-to-volume ratio of nanochannels. Unlike random bulk formation, the high surface-to-volume ratio in nanochannels ensures exhaustive molecular recruitment, enabling millisecond-scale equilibration and precise thickness programming governed by diffusion-limited transport physics (δ=Q0.3). Furthermore, the formed condensates exhibit viscous dewetting dynamics, allowing for flow-tunable manipulation including nm-scale thickness control and reversible hydrodynamic peel-off. The unique properties of these surface LLPS reactors hold the potential to overcome limitations of conventional approaches for functional molecule immobilization on 2D surfaces. Examples include the high-capacity accommodation of functional molecules within 3D condensed phases, the dynamic operation of the reactors themselves, and the implementation of complex interactions such as substrate channeling.

8 February 2015 in arXiv
Verified
Preprint
Open access
PDF file
MHM. Harada
M. Harada
SHS. Hasegawa
S. Hasegawa
YKY. Kasugai
Y. Kasugai
SMShin-Ichiro Meigo
Shin-Ichiro Meigo
KSK. Sakai
K. Sakai
JSJ. Spitz
J. Spitz
At the 17th J-PARC PAC, which was held on September 2013, we proposed the sterile neutrino search at J-PARC MLF. After reviewing the proposal, PAC recommended to have a background measurement at the detector's candidate site location in their report to investigate whether the background rates can be manageable for the real experiment or not. Therefore, we have performed the background measurements (MLF; 2013BU1301 test experiment) during the summer of 2014, also following the 18th J-PARC PAC recommendations, and the measurements results are described here.