Kazuhiro Sakai

Kazuhiro Sakai

Auto-generated profile, based on publicly available information

Kazuhiro Sakai

Center for Space Sciences and Technology, University of Maryland, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2019 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
SBSimon R. Bandler
Simon R. Bandler
JCJames A. Chervenak
James A. Chervenak
ADAaron M. Datesman
Aaron M. Datesman
ADArchana M. Devasia
Archana M. Devasia
MDMichael J. DiPirro
Michael J. DiPirro
BZBen Zeiger
Ben Zeiger
Lynx is an observatory with an x-ray optic with the same focal length of 10 m as Chandra.1 It will have a similar angular resolution as Chandra of 0.5 arc sec but will have orders of magnitude more area and greater off-axis angular resolution, allowing for substantially deeper observations to study arc second astrophysical features in crowded regions of the sky.

19 March 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MDMalcolm Durkin
Malcolm Durkin
JAJoseph S. Adams
Joseph S. Adams
SBSimon R. Bandler
Simon R. Bandler
JCJames A. Chervenak
James A. Chervenak
SCSaptarshi Chaudhuri
Saptarshi Chaudhuri
BYBetty A. Young
Betty A. Young
Time-division multiplexing (TDM) is the backup readout technology for the X-ray Integral Field Unit (X-IFU), a 3168-pixel X-ray transition-edge sensor (TES) array that will provide imaging spectroscopy for european space agency's Athena satellite mission. X-IFU design studies are considering readout with a multiplexing factor of up to 40. We present data showing 40-row TDM readout (32 TES rows + 8 repeats of the last row) of TESs that are of the same type as those being planned for X-IFU, using measurement and analysis parameters within the ranges specified for X-IFU. Single-column TDM measurements have best-fit energy resolution of (1.91 ± 0.01) eV for the Al Kα complex (1.5 keV), (2.10 ± 0.02) eV for Ti Kα (4.5 keV), (2.23 ± 0.02) eV for Mn Kα (5.9 keV), (2.40 ± 0.02) eV for Co Kα (6.9 keV), and (3.44 ± 0.04) eV for Br Kα (11.9 keV). Three-column measurements have best-fit resolution of (2.03 ± 0.01) eV for Ti Kα and (2.40 ± 0.01) eV for Co Kα. The degradation due to the multiplexed readout ranges from 0.1 eV at the lower end of the energy range to 0.5 eV at the higher end. The demonstrated performance meets X-IFU's energy-resolution and energy-range requirements. True 40-row TDM readout, without repeated rows, of kilopixel scale arrays of X-IFU-like TESs is now under development.

24 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SSStephen J. Smith
Stephen J. Smith
JAJoseph S. Adams
Joseph S. Adams
SBSimon R. Bandler
Simon R. Bandler
SBSophie Beaumont
Sophie Beaumont
JCJames A. Chervenak
James A. Chervenak
MWMichael C. Witthoeft
Michael C. Witthoeft
Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA's Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including > 200 pixels, of: 1.95 eV for Ti-Kα (4.5 keV), 1.97 eV for Mn-Kα (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma statistical errors are ≤0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

23 April 2019 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
NWN. A. Wakeham
N. A. Wakeham
JAJ. S. Adams
J. S. Adams
SBS. R. Bandler
S. R. Bandler
SBS. Beaumont
S. Beaumont
JCJ. A. Chervenak
J. A. Chervenak
EWE. J. Wassell
E. J. Wassell
In many superconducting transition-edge sensor (TES) microcalorimeters, the measured electrical noise exceeds theoretical estimates based on a thermal model of a single body thermally connected to a heat bath. Here, we report on noise and complex impedance measurements of a range of designs of TESs made with a Mo/Au bilayer. We have fitted the measured data using a two-body model, where the x-ray absorber and the TES are connected by an internal thermal conductance Gae. We find that the so-called excess noise measured in these devices is consistent with the noise generated from the internal thermal fluctuations between the x-ray absorber and the TES. Our fitted parameters are consistent with the origin of Gae being from the finite thermal conductance of the TES itself. These results suggest that even in these relatively low resistance Mo/Au TESs, the internal thermal conductance of the TES may add significant additional noise and could account for all the measured excess noise. Furthermore, we find that around regions of the superconducting transition with rapidly changing derivative of resistance with respect to temperature, an additional noise mechanism may dominate. These observations may lead to a greater understanding of TES devices and allow the design of TES microcalorimeters with improved performance.

22 March 2019 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
DBDouglas A. Bennett
Douglas A. Bennett
JMJohn A. B. Mates
John A. B. Mates
SBSimon R. Bandler
Simon R. Bandler
DBDaniel T. Becker
Daniel T. Becker
JFJoseph W Fowler
Joseph W Fowler
AWAbigail L. Wessels
Abigail L. Wessels
The Lynx x-ray microcalorimeter (LXM) is an imaging spectrometer proposed as part of the Lynx satellite mission concept currently under study to be a National Aeronautics and Space Administration (NASA) flagship mission.1 Lynx will enable unique astrophysical observations into the x-ray universe due to its high angular resolution and large field of view. Because Lynx will improve sensitivity by two orders of magnitude compared to Chandra,2 it will be able to penetrate into the epoch of reionization to detect x-rays from black holes lighting up the first galaxies and map the baryons in the Cosmic Web and galactic halos.3 Since the majority of the baryonic matter in the universe is visible in either x-ray emission or absorption, Lynx will be a powerful tool for understanding the origins of the cosmos.

8 April 2019 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Open access
PDF file
SSStephen J. Smith
Stephen J. Smith
JAJoseph S. Adams
Joseph S. Adams
SBSimon R. Bandler
Simon R. Bandler
JCJames A. Chervenak
James A. Chervenak
ADAaron M. Datesman
Aaron M. Datesman
EWEdward J. Wassell
Edward J. Wassell
Transition-edge sensors (TESs) are sensitive microcalorimeters under the development for a variety of applications in photon and particle spectroscopy.1,2 These devices consist of a thin superconducting film that is electrically biased in the highly temperature sensitive superconducting-to-normal transition region. Absorption of photon or particle energy causes a change in resistance of the sensor, which is measured as a current change by a superconducting quantum interference device (SQUID) ammeter. We are currently pursuing large format TES arrays3,4 to meet the requirements of proposed future x-ray astronomy missions.5,6 These applications require high fill-factor, kilo-pixel arrays capable of achieving full-width-half maximum (FWHM) energy resolution, ΔEFWHM, of typically a few electron volts in the energy range 0.3 to 10 keV. The maximum number of pixels used in TES arrays is constrained by a number of practical challenges. Position-sensitive microcalorimeters are an alternative approach that provides a means to increase the number of pixels within an array, at some compromise in performance, without the commensurate increase in the number of readout components, wires, and electrical connections. Although position-sensitive microcalorimeters have been investigated in a variety of different forms,7 8. 9. 10. – 11 our recent focus has been on the use of multiabsorber TESs commonly referred to as “hydras.”12,13 These devices consist of a series of individual x-ray absorbers with a different thermal conductance or “link” to a single TES. Each of these links acts as a thermal low-pass filter that gives rise to a different characteristic pulse shape for an x-ray absorbed in each pixel of the hydra. Thus these detectors can be used to provide larger focal plane coverage, or improved angular resolution for the same coverage, at some expense of performance (energy resolution and counting-rate) when compared to arrays of independent pixels. This type of detector has been proposed for a variety of different x-ray mission concepts over the past decade such as the international x-ray observatory (IXO).11,12 For IXO, the hydras were proposed as a way to increase the size of the focal-plane array around a core main array of single-pixel TESs and thus provide a greatly expanded instrument field-of-view (FOV) with only a limited increase in complexity. Results from prototype 4-pixel hydras have demonstrated ΔEFWHM=5 to 6 eV at an x-ray energy of 5.9 keV for devices with a 0.25-mm absorber pitch.12,13