Paolo Guidorzi

Dr. Paolo Guidorzi

DIN, University of Bologna, Bologna, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2000 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
Massimo GaraiMassimo Garai
Massimo Garai
PGPaolo Guidorzi
Paolo Guidorzi
In the frame of the 1994–1997 Standard, Measurement and Testing program, the European Commission funded a research project, named Adrienne, to define new test methods for measuring the intrinsic characteristics of road traffic noise reducing devices in situ. The research team produced innovative methods for testing the sound reflection/absorption and the airborne sound insulation characteristics of noise barriers. These methods are now under consideration at CEN (European Committee for Standardization), to become European standards. The present work reports a detailed verification of the test method for airborne sound insulation over a selection of 17 noise barriers, representative of the Italian and European production. The samples were tested both outdoors, using the new Adrienne method, and in laboratory, following the European standard EN 1793-2. In both cases the single number rating for airborne sound insulation recommended by the European standard was calculated. The new method proved to be easy to use and reliable for all kinds of barriers. It has been found sensitive to quality of mounting, presence of seals, and other details typical of outdoor installations. The comparison between field and laboratory results shows a good correlation, while existing differences can be explained with the different sound fields and mounting conditions between the outdoor and laboratory tests. It is concluded that the Adrienne method is adequate for its intended use.

1 November 2015 in Energy Procedia
Verified
Journal Article
Open access
PGPaolo Guidorzi
Paolo Guidorzi
LBLuca Barbaresi
Luca Barbaresi
Dario D'OrazioDario D'Orazio
Dario D'Orazio
Massimo GaraiMassimo Garai
Massimo Garai
The measurement of impulse responses inside of a room or a theatre is a critical task in architectural acoustics. The impulse responses are usually measured using either Exponential Sine Sweep (ESS) or Maximum Length Sequence (MLS) signals. The theory behind MLS generation and use is well developed and does not involve computational problems. When a non-linear system is measured, the distortion appears in the deconvolved impulse response as a series of peaks distributed over time, in deterministic positions. In case of presence of noise during the measurement, the phase of any spurious noise, even an impulsive one, is randomly distributed over the entire length of the recovered impulse response. The ESS signal shows some advantages over MLS, such as a better signal to noise ratio (SNR) and a robust non-linearity rejection. Typically, in the same conditions, the ESS has a dynamic range of about 15dB higher than MLS. Nonetheless, the generation of an ESS signal and the subsequent analysis of impulse responses involve some problems whose solutions are not yet common practice and short impulsive noises can contaminate the sampled data, causing bad effects on the deconvolved impulse response, in form of a frequency decreasing sweep. For the above mentioned reasons ESS is generally more suitable than MLS for use in architectural acoustics, but in some cases the use of MLS signal is still to be preferred. Differences and advantages between impulse response measurements obtained by means of MLS or ESS, are analyzed and discussed in this paper and an in-depth analysis of both measurement methods is presented. Some case studies of impulse response measurements performed inside historical Italian opera houses using both MLS and ESS, in non-ideal conditions (for example in presence of spurious noise), are presented and examined, highlighting differences, advantages and pitfalls of both measurement methods

11 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LRLuigi Russi
Luigi Russi
PGPaolo Guidorzi
Paolo Guidorzi
Beatrice PulvirentiBeatrice Pulvirenti
Beatrice Pulvirenti
Davide AguiariDavide Aguiari
Davide Aguiari
Giovanni PauGiovanni Pau
Giovanni Pau
Giovanni SempriniGiovanni Semprini
Giovanni Semprini
This work is aimed at the experimental characterisation of air quality and thermal profile within an electric vehicle cabin, measuring at the same time the HVAC system energy consumption. Pollutant concentrations in the vehicle cabin are measured by means of a low-cost system of sensors. The effects of the HVAC system configuration, such as fresh-air and recirculation mode, on cabin air quality, are discussed. It is shown that the PM concentrations observed in recirculation mode are lower than those in fresh-air mode, while VOC concentrations are generally higher in recirculation than in fresh-air mode. The energy consumption is compared in different configurations of the HVAC system. The novelty of this work is the combined measurement of important comfort parameters such as air temperature distribution and air quality within the vehicle, together with the real time energy consumption of the HVAC system. A wider concept of comfort is enabled, based on the use of low-cost sensors in the automotive field.

1 December 2015 in Building and Environment
Verified
Journal Article
Closed access
Massimo GaraiMassimo Garai
Massimo Garai
PGPaolo Guidorzi
Paolo Guidorzi

1 November 2014 in Acta Acustica united with Acustica
Verified
Journal Article
Closed access
Massimo GaraiMassimo Garai
Massimo Garai
ESEric Schoen
Eric Schoen
GBGottfried Behler
Gottfried Behler
BBBeatriz Bragado
Beatriz Bragado
MCMichael Chudalla
Michael Chudalla
PGPaolo Guidorzi
Paolo Guidorzi

27 December 2019 in Future Cities and Environment
Verified
Journal Article
Open access
PDF file
Giovanni SempriniGiovanni Semprini
Giovanni Semprini
Aminhossein JahanbinAminhossein Jahanbin
Aminhossein Jahanbin
Beatrice PulvirentiBeatrice Pulvirenti
Beatrice Pulvirenti
PGPaolo Guidorzi
Paolo Guidorzi
An accurate assessment of thermal comfort inside a building is essential since it is associated to the human’s perception of well-being and comfort. In the present study, a 3D computational fluid dynamic (CFD) code is employed to evaluate the indoor comfort indexes for a university office located in a historical building, built of thick masonry walls and of large single-glass windows, using fan coil as an air conditioning system. The experimental measurement has been carried out to validate the numerical model and to obtain the required initial and boundary conditions. The experimental set-up employs an innovative system for the sensor localization, based on acoustic sources, signal processing and trilateration algorithms. By means of finite volume method, the turbulent air flow, the local heat transfer characteristics and the operative temperature inside the room are obtained for a typical winter day. The results yielded by numerical simulations allow to evaluate thermal comfort condition at working places inside the office and to identify the best comfort areas. The results show that even when the air temperature is quite uniform inside the room, the operative temperature at the positions where occupants are placed is significantly affected by surface temperature of the windows, due to the large window to wall surface ratio and also by the position and operational condition of fan coil. It is concluded that 3D comfort map allows to optimize internal layout of the office room; furthermore, the possibility of thermal comfort optimization in specific workstation together with local control of heating system lead to gain remarkable energy saving results.