Abliz Yimit

Prof. Abliz Yimit

Institute of Applied Chemistry, College of Chemistry, Xinjiang University, Urumqi, 830046, Xinjiang, PR China
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2003 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
AYAbliz Yimit
Abliz Yimit
KIKiminori Itoh
Kiminori Itoh
MMMasayuki Murabayashi
Masayuki Murabayashi

4 May 2018 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
HAHannikezi Abudukeremu
Hannikezi Abudukeremu
NKNuerguli Kari
Nuerguli Kari
YZYuan Zhang
Yuan Zhang
JWJiaming Wang
Jiaming Wang
PNPatima Nizamidin
Patima Nizamidin
AYAbliz Yimit
Abliz Yimit

13 March 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
NKNuerguli Kari
Nuerguli Kari
Marco ZannottiMarco Zannotti
Marco Zannotti
Rita GiovannettiRita Giovannetti
Rita Giovannetti
DRDavid Reha
David Reha
BMBabak Minofar
Babak Minofar
AYAbliz Yimit
Abliz Yimit
Metal effects on the gas sensing behavior of metal complexes of 5,10,15,20-tetrakis(4-hydroxyphenyl)porphyrin (THPP) thin film was investigated in terms of detecting NO2 gas by the planar optical waveguide. For this purpose, several THPP and metal complexes were synthesized with different central metal ions: Co(II), Ni(II), Cu(II), and Zn(II). Planar optical gas sensors were fabricated with the metalloporphyrins deposited on K+ ion-exchanged soda-lime glass substrate with the spin coating method serving as host matrices for gas interaction. All of the THPP complex’s films were fully characterized by UV-Vis, IR and XPS spectroscopy, and the laser light source wavelength was selected at 520 and 670 nm. The results of the planar optical waveguide sensor show that the Zn–THPP complex exhibits the strongest response with the lowest detectable gas concentration of NO2 gas for both 520 nm and 670 nm. The Ni–THPP and Co–THPP complexes display good efficiency in the detection of NO2, while, on the other hand, Cu–THPP shows a very low interaction with NO2 gas, with only 50 ppm and 200 ppm detectable gas concentration for 520 nm and 670 nm, respectively. In addition, molecular dynamic simulations and quantum mechanical calculations were performed, proving to be coherent with the experimental results.

1 February 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
TGTurdi Gulmira
Turdi Gulmira
PNPatima Nizamidin
Patima Nizamidin
NKNuerguli Kari
Nuerguli Kari
AYAbliz Yimit
Abliz Yimit
FWFu Wang
Fu Wang
5,10,15,20-Tetraphenylporphyrin (TPP) was synthesized, and a glass optical waveguide (OWG) was coated with a gas-phase protonated TPP thin film to develop a sensor for NH3 gas detection.

1 November 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PNPatima Nizamidin
Patima Nizamidin
AYAbliz Yimit
Abliz Yimit
Yan YinYan Yin
Yan Yin
BKBuayishamu Kutilike
Buayishamu Kutilike
NKNuerguli Kari
Nuerguli Kari
GMGulgina Mamtimin
Gulgina Mamtimin

19 January 2018 in Analytical Letters
Verified
Journal Article
Closed access
PNPatima Nizamidin
Patima Nizamidin
YYYan Yin
Yan Yin
GTGulmira Turdi
Gulmira Turdi
AYAbliz Yimit
Abliz Yimit
The influence of heat-treatment temperature on the optical properties (refractive index, transmittance, and attenuation) and gas sensitivities of nickel-doped lithium iron phosphate (LiFe0.99Ni0.01PO4) thin films were discussed. LiFe0.99Ni0.01PO4 was synthesized in one step using hydrothermal methods and fixed to tin-diffused glass as a sensing film by spin-coating before calcination at different temperatures. The obtained thin films were characterized by refractive index, thickness, attenuation, and porosity, as well as gas sensing performances for benzene, toluene, and xylene. The experimental results indicated that the LiFe0.99Ni0.01PO4 thin films dried at 450°C displayed higher refractive indices, good transparency, and less attenuation; thus, the resulting sensor of a LiFe0.99Ni0.01PO4 thin film/tin-diffused optical wave-guide exhibited a greater response to xylene in the concentration range of 0.1–1000 ppm.