The presented work focuses on the influence of a water-soluble derivative of cellulose, hydroxyethyl methyl cellulose (HEMC), on gypsum thermal properties. The polymer is used as an additive in the weight fraction, up to 1% of pure gypsum. The water-to-gypsum ratio was taken at a level of 0.74. The study of hemihydrate calcium sulphate hydration of crystalline form was observed using own-made apparatus measuring the temperature of the system during hydration. The presence of the polymer leads to a retardation of the hydration and setting process of gypsum paste. For the purpose of conductivity measurements, an improved method with a “hot wire” setup was used. A decrease of thermal conductivity and density with added HEMC was observed because of structure modifications of the gypsum product. It was concluded that adding HEMC influences not only the water retention coefficient and the rate of setting of gypsum, it also changes the morphological structure of gypsum-polymer composite, which is reflected in the density and thermal conductivity of the final product.
— High‐resolution transmission electron microscopy micrographs of acid‐resistant residues of the Allende, Leoville, and Vigarano meteorites show a great variety of carbon structures: curved and frequently twisted and intertwined graphene sheets, abundant carbon black‐like particles, and hollow “sacs”. It is suggested that perhaps all of these are carriers for the planetary Q‐noble gases in these meteorites. Most of these materials are pyrocarbons that probably formed by the pyrolysis of hydrocarbons either in a gas phase, or on hot surfaces of minerals. An attempt was made to analyze for argon with particle‐induced x‐ray emission in 143 spots of grains of floating and suspended matter from freeze‐dry cycles of an Allende bulk sample in water, and floating “black balls” from sonication in water of samples from the Allende meteorite. The chemical compositions of these particles were obtained, but x‐ray signals at the wavelength of argon were obtained on only a few spots.
This article contains the results of experimental studies of a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken from a progressing turbulent flow within Reynolds numbers (Re = 4700–19,500). Based on conducted experimental data, flow characteristics, and discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 to 0.68 dm3/s, based on rules from the GUM international standard. The value, determined from uncertainty analysis, did not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19,500.
The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distorting element. Clamp-on ultrasonic flow meters are popular among measurement technologies due to their high accuracy and easy, non-invasive installation, because the sensors are mounted directly on the outer surface of the pipe. In industrial applications, installation space is usually limited and, therefore, flow meters frequently have to be mounted directly behind flow disturbances. In such cases, it is necessary to determine the value of the correction factor. The disturbing element was a knife gate valve, a valve often used in flow installations. Water flow velocity tests were performed using an ultrasonic flow meter with clamp-on sensors on the pipeline. The research was performed in 2 series of measurements with different Reynolds numbers of 35,000 and 70,000, which correspond to a velocity of approximately 0.9 m/s and 1.8 m/s. The tests were carried out at different distances from the source of interference, within the range of 3–15 DN (pipe nominal diameter). The position of the sensors at successive measurement points on the circuit of the pipeline was changed by 30 degrees. Flow velocity measurements were carried out for two different levels of the valve’s closure: 1/3 and 1/2 of the valve’s height. For the collected velocity values at single measurement points, the values of the correction coefficient, K, were determined. The results of the tests and calculations prove that compensation error of measurement performed behind the disturbance without keeping the required straight sections of the pipeline is possible by using the factor K*. The analysis of the results made it possible to identify the optimal measuring point at a distance from the knife gate valve as being smaller than specified in the standards and recommendations.
The article contains the results of experimental studies for a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken for a progressing turbulent flow within Reynolds numbers (Re = 4700...19500). Based on experimental data, flow characteristics as well as discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 dm3/s to 0.68 dm3/s. The value does not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19500.
7 August 2023 in Advances in Science and Technology Research Journal
The subject of this paper is the effect of changing the roughness of the inflow surface of an orifice on its characteristics. A sloping segmental orifice was chosen as the reducer and its surface roughness was changed by lining its inflow surface with sandpaper of different roughness parameters....