Piotr Krzysztof Piechota

Dr. Piotr Krzysztof Piechota


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PSPiotr Krzysztof Synowiec
Piotr Krzysztof Synowiec
AAArtur Andruszkiewicz
Artur Andruszkiewicz
WWWiesław Wędrychowicz
Wiesław Wędrychowicz
PPPiotr Krzysztof Piechota
Piotr Krzysztof Piechota
EWElżbieta Wróblewska
Elżbieta Wróblewska
The subject matter of the article concerns velocities/flow rate measurements in the area of disturbed flows-behind the 90° bend. They were conducted by means of an ultrasonic flowmeter with clamp-on sensors on pipeline, for water and two different Reynolds numbers of 70,000 and 100,000, corresponding to two velocities of approximately 1.42 m/s and 2.04 m/s. The tests were carried out at 12 distances from the disturbance. Sensors on the circumference of the pipeline were mounted 30° each. The correction factor values were calculated for the given measurement geometry. The measurements have shown that the values of this coefficient are always greater than 1, which means that the ultrasonic flow meter understates the speed values. They also showed that already at a distance of 8 nominal diameters from the disturbance, the correction factor does not exceed 1.02, so the measurement errors are within the maximum permissible error (MPE) of a typical ultrasonic flow meter. For distances less than eight nominal diameters from the disturbance, not taking the correction factor value into the account can lead to systematic errors of up to 10.8%. Studies have also proved that in each measurement plane behind the disturbance there are two mounting angles for the ultrasonic sensors, 60° and 240° respectively, for which the correction factor values are minimal. Additionally, using the laser Doppler anemometry (LDA) method, velocity solids were determined at individual distances from the disturbance, and the projections of velocity blocks on the appropriate plane represented velocity profiles and indicated the distances from the disturbance at which these profiles stabilise.

11 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PPPiotr Krzysztof Piechota
Piotr Krzysztof Piechota
PSPiotr Krzysztof Synowiec
Piotr Krzysztof Synowiec
AAArtur Andruszkiewicz
Artur Andruszkiewicz
WWWiesław Wędrychowicz
Wiesław Wędrychowicz
EWElżbieta Wróblewska
Elżbieta Wróblewska
AMAndrzej Mrowiec
Andrzej Mrowiec
The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distorting element. Clamp-on ultrasonic flow meters are popular among measurement technologies due to their high accuracy and easy, non-invasive installation, because the sensors are mounted directly on the outer surface of the pipe. In industrial applications, installation space is usually limited and, therefore, flow meters frequently have to be mounted directly behind flow disturbances. In such cases, it is necessary to determine the value of the correction factor. The disturbing element was a knife gate valve, a valve often used in flow installations. Water flow velocity tests were performed using an ultrasonic flow meter with clamp-on sensors on the pipeline. The research was performed in 2 series of measurements with different Reynolds numbers of 35,000 and 70,000, which correspond to a velocity of approximately 0.9 m/s and 1.8 m/s. The tests were carried out at different distances from the source of interference, within the range of 3–15 DN (pipe nominal diameter). The position of the sensors at successive measurement points on the circuit of the pipeline was changed by 30 degrees. Flow velocity measurements were carried out for two different levels of the valve’s closure: 1/3 and 1/2 of the valve’s height. For the collected velocity values at single measurement points, the values of the correction coefficient, K, were determined. The results of the tests and calculations prove that compensation error of measurement performed behind the disturbance without keeping the required straight sections of the pipeline is possible by using the factor K*. The analysis of the results made it possible to identify the optimal measuring point at a distance from the knife gate valve as being smaller than specified in the standards and recommendations.

7 August 2023 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
AMAndrzej Mrowiec
Andrzej Mrowiec
AAArtur Andruszkiewicz
Artur Andruszkiewicz
PPPiotr Krzysztof Piechota
Piotr Krzysztof Piechota
The subject of this paper is the effect of changing the roughness of the inflow surface of an orifice on its characteristics. A sloping segmental orifice was chosen as the reducer and its surface roughness was changed by lining its inflow surface with sandpaper of different roughness parameters....