Surej Mouli

Dr. Surej Mouli

Aston University
+1
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013
Verified
Conference Paper
Closed access
Surej MouliSurej Mouli
Surej Mouli
RPRamaswamy Palaniappan
Ramaswamy Palaniappan
ISIan P. Sillitoe
Ian P. Sillitoe
JGJohn Gan
John Gan
Among the many paradigms used in brain-computer interface (BCI), steady state visual evoked potential (SSVEP) offers the quickest response; however it is disadvantageous from the point of view of visual fatigue, which prevents subjects from prolonged usage of visual stimuli especially when LEDs are used. In this paper, we propose a visual stimulator using readily available RGB LEDs with clear and frosted glass, with the latter being tested for performance and qualitative user comfort using electroencephalogram (EEG) data from four subjects. Furthermore, we also compare frosted and clear stimuli for three colours Red, Green and Blue with frequency values of 7, 8, 9 and 10 Hz. The results using band-pass filtering and Fast Fourier Transform showed that 7 Hz Green clear LED stimuli gave the highest response in general, although all the subjects indicated that they were more comfortable with frosted LED stimuli.

1 October 2016
Verified
Conference Paper
Closed access
Surej MouliSurej Mouli
Surej Mouli
RPRamaswamy Palaniappan
Ramaswamy Palaniappan
This study investigates the influence of LED visual stimulus brightness in evoking steady state visual evoked potential (SSVEP) responses in brain which can be utilised for vision research, medical diagnostics or for developing brain-computer interfaces (BCI). LED visual stimulus was based on a radial 130 mm chip on board (COB) LEDs emitting green light. The frequencies of the flickers were precisely controlled by a 32-bit microcontroller platform to generate SSVEP with high accuracy. For this study the luminosity of the visual stimulus was controlled externally at levels of 25, 50, 75 and 100% of the maximum visual stimulus brightness. The SSVEP frequencies used to investigate the luminosity effect were 7, 8, 9 and 10 Hz for a period of 30 seconds for all the four luminous levels of the visual stimulus. The study analysed the EEG recordings from five participants comprising of five trials for each frequency and luminous levels of visual stimulus. The results indicated that luminosity at 75% of the full brightness gave significantly higher response for all participants when compared to other luminous levels of the visual stimulus with reduced visual fatigue.

24 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AHAmy Harrison
Amy Harrison
AJAndrea Jester
Andrea Jester
Surej MouliSurej Mouli
Surej Mouli
Antonio FratiniAntonio Fratini
Antonio Fratini
AJAli Jabran
Ali Jabran
Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation. However, current clinical methods rely on subjective observations and limited tests. Smart gloves with inertial measurement unit (IMU) sensors have emerged as tools for capturing digit movements, yet their sensor accuracy remains underexplored. This study developed and validated an IMU-based smart glove system for measuring finger joint movements in individuals with hand differences. The glove measured 3D digit rotations and was evaluated against an industrial robotic arm. Tests included rotations around three axes at 1°, 10°, and 90°, simulating extension/flexion, supination/pronation, and abduction/adduction. The IMU sensors demonstrated high accuracy and reliability, with minimal systematic bias and strong positive correlations (p > 0.95 across all tests). Agreement matrices revealed high agreement (10°) in only 4 trials. The Root Mean Square Error (RMSE) ranged from 1.357 to 5.262 for the 90° tests, 0.094 to 0.538 for the 10° tests, and 0.129 to 0.36 for the 1° tests. Likewise, mean absolute error (MAE) ranged from 0.967 to 4.679 for the 90° tests, 0.073 to 0.386 for the 10° tests, and 0.102 to 0.309 for the 1° tests. The sensor provided precise measurements of digit angles across 0–90° in multiple directions, enabling reliable clinical assessment, remote monitoring, and improved diagnosis, treatment, and rehabilitation for individuals with hand differences.

22 May 2020 in HardwareX
Verified
Journal Article
Open access
Surej MouliSurej Mouli
Surej Mouli
RPRamaswamy Palaniappan
Ramaswamy Palaniappan
A fully customisable chip-on board (COB) LED design to evoke two brain responses simultaneously (steady state visual evoked potential (SSVEP) and transient evoked potential, P300) is discussed in this paper. Considering different possible modalities in brain-computer interfacing (BCI), SSVEP is widely accepted as it requires a lesser number of electroencephalogram (EEG) electrodes and minimal training time. The aim of this work was to produce a hybrid BCI hardware platform to evoke SSVEP and P300 precisely with reduced fatigue and improved classification performance. The system comprises of four independent radial green visual stimuli controlled individually by a 32-bit microcontroller platform to evoke SSVEP and four red LEDs flashing at random intervals to generate P300 events. The system can also record the P300 event timestamps that can be used in classification, to improve the accuracy and reliability. The hybrid stimulus was tested for real-time classification accuracy by controlling a LEGO robot to move in four directions.

5 November 2020 in Technologies
Verified
Journal Article
Open access
PDF file
Surej MouliSurej Mouli
Surej Mouli
Ramaswamy PalaniappanRamaswamy Palaniappan
Ramaswamy Palaniappan
Emmanuel MolefiEmmanuel Molefi
Emmanuel Molefi
Ian McLoughlinIan McLoughlin
Ian McLoughlin
Steady State Visual Evoked Potential (SSVEP) methods for brain–computer interfaces (BCI) are popular due to higher information transfer rate and easier setup with minimal training, compared to alternative methods. With precisely generated visual stimulus frequency, it is possible to translate brain signals into external actions or signals. Traditionally, SSVEP data is collected from the occipital region using electrodes with or without gel, normally mounted on a head cap. In this experimental study, we develop an in-ear electrode to collect SSVEP data for four different flicker frequencies and compare against occipital scalp electrode data. Data from five participants demonstrates the feasibility of in-ear electrode based SSVEP, significantly enhancing the practicability of wearable BCI applications.

17 February 2017 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
Surej MouliSurej Mouli
Surej Mouli
Ramaswamy PalaniappanRamaswamy Palaniappan
Ramaswamy Palaniappan
Steady‐state visual evoked response (SSVEP) is widely used in visual‐based diagnosis and applications such as brain–computer interfacing due to its high information transfer rate and the capability to activate commands through simple gaze control. However, one major impediment in using flashing visual stimulus to obtain SSVEP is eye fatigue that prevents continued long‐term use preventing practical deployment. This combined with the difficulty in establishing precise pulse‐width modulation (PWM) that results in poorer accuracy warrants the development of appropriate approach to solve these issues. Various studies have suggested the usage of high frequencies of visual stimulus to reduce the visual fatigue for the user but this results in poor response performance. Here, the authors study the use of extremely high duty‐cycles in the stimulus in the hope of solving these constraints. Electroencephalogram data was recorded with PWM duty‐cycles of 50–95% generated by a precise custom‐made light‐emitting diode hardware and tested ten subjects responded that increasing duty‐cycles had less visual strain for all the frequency values and the SSVEP exhibited a subject‐independent peak response for duty‐cycle of 85%. This could pave the way for increased usage of SSVEP for practical applications.