Ali Jabran

Dr. Ali Jabran

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
AJAli Jabran
Ali Jabran
CPChris Peach
Chris Peach
LRLei Ren
Lei Ren
Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use. A comprehensive review of in vitro biomechanical studies is needed for the comparison of plates’ mechanical performance and the testing methodologies. This will not only guide clinicians with plate selection but also with the design of future in vitro biomechanical studies. This review was aimed to systematically categorise and review the in vitro biomechanical studies of these plates based on their protocols and discuss their results. The technologies and techniques investigated in these studies were categorised and compared to reach a census where possible. Web of Science and Scopus database search yielded 62 studies. Out of these, 51 performed axial loading, torsion, bending and/or combined bending and axial loading while 11 simulated complex glenohumeral movements by using tendons. Loading conditions and set-up, failure criteria and performance parameters, as well as results for each study, were reviewed. Only two studies tested four-part fracture model while the rest investigated two- and three-part fractures. In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load–displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. Overall, PHILOS was the most tested plate and locking plates demonstrated better mechanical performance than non-locking ones. Conflicting results have been published for their comparison with non-locking blade plates and polyaxial locking screws. Augmentation with cement [calcium phosphate or poly(methyl methacrylate)] or allografts (fibular and femoral head) was found to improve bone-plate constructs’ mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.

1 February 2019 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
JLJing Liu
Jing Liu
ZQZhihui Qian
Zhihui Qian
KWKunyang Wang
Kunyang Wang
JWJianan Wu
Jianan Wu
AJAli Jabran
Ali Jabran
LRLei Ren
Lei Ren
The objective of this study was to investigate the feasibility of using shear wave elastography (SWE) to indirectly measure passive muscle force and to examine the effects of muscle mass and scan angle. We measured the Young's moduli of 24 specimens from six muscles of four swine at different passive muscle loads under different scan angles (0°, 30°, 60° and 90°) using SWE. Highly linear relationships between Young's modulus E and passive muscle force F were found for all 24 muscle specimens at 0o scan angle with coefficients of determination R2 ranging from 0.984 to 0.999. The results indicate that the muscle mass has no significant effect on the muscle E-F relationship, whereas E-F linearity decreases disproportionately with increased scan angle. These findings suggest that SWE, when carefully applied, can provide a highly reliable tool to measure muscle Young's modulus, and could be used to assess the muscle force quantitatively.

1 November 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
AJAli Jabran
Ali Jabran
CPChris Peach
Chris Peach
ZZZhenmin Zou
Zhenmin Zou
LRLei Ren
Lei Ren
Optimal treatment of proximal humerus fractures remains controversial. Locking plates offer theoretical advantages but are associated with complications in the clinic. This study aimed to perform parametric design optimisation of proximal humerus plates to enhance their mechanical performance. A finite element (FE) model was developed that simulated a two-part proximal humerus fracture that had been treated with a Spatial Subchondral Support (S3) plate and subjected to varus bending. The FE model was validated against in vitro biomechanical test results. The predicted load required to apply 5 mm cantilever varus bending was only 0.728% lower. The FE model was then used to conduct a parametric optimisation study to determine the orientations of inferomedial plate screws that would yield minimum fracture gap change (i.e. optimal stability). The feasible design space was automatically identified by imposing clinically relevant constraints, and the creation process of each FE model for the design optimisation was automated. Consequently, 538 FE models were generated, from which the obtained optimal model had 4.686% lower fracture gap change (0.156 mm) than that of the manufacturer’s standard plate. Whereas its screws were oriented towards the inferomedial region and within the range of neck-shaft angle of a healthy subject. The methodology presented in this study promises future applications in patient-specific design optimisation of implants for other regions of the human body.

10 May 2018 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
HHHuajie Hong
Huajie Hong
AJAli Jabran
Ali Jabran
LRLei Ren
Lei Ren
Research on the cable-driven mechanism has greatly developed with the booming of the robots in the past 30 years, and a range of corresponding theoretical studies have been published on them. The large-scale robot or manipulator with the complex cable-driven mechanism can be reconfigured. However, more theoretical studies are required on their topological architecture design and optimization to achieve this. Therefore, the applied cable-driven architectures and the corresponding theoretical studies are reviewed and summarized here. The parallel, serial, and differential architecture are illustrated, as well as their theories and methods, such as the workspace analysis based on the Jacobian matrix, particle swarm optimization and genetic algorithm, and kinematic design based on the graph theory are described. The features of the architecture and the theory studies are concluded. It is hoped that this study will help with design of future studies.

24 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AHAmy Harrison
Amy Harrison
AJAndrea Jester
Andrea Jester
Surej MouliSurej Mouli
Surej Mouli
Antonio FratiniAntonio Fratini
Antonio Fratini
AJAli Jabran
Ali Jabran
Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation. However, current clinical methods rely on subjective observations and limited tests. Smart gloves with inertial measurement unit (IMU) sensors have emerged as tools for capturing digit movements, yet their sensor accuracy remains underexplored. This study developed and validated an IMU-based smart glove system for measuring finger joint movements in individuals with hand differences. The glove measured 3D digit rotations and was evaluated against an industrial robotic arm. Tests included rotations around three axes at 1°, 10°, and 90°, simulating extension/flexion, supination/pronation, and abduction/adduction. The IMU sensors demonstrated high accuracy and reliability, with minimal systematic bias and strong positive correlations (p > 0.95 across all tests). Agreement matrices revealed high agreement (10°) in only 4 trials. The Root Mean Square Error (RMSE) ranged from 1.357 to 5.262 for the 90° tests, 0.094 to 0.538 for the 10° tests, and 0.129 to 0.36 for the 1° tests. Likewise, mean absolute error (MAE) ranged from 0.967 to 4.679 for the 90° tests, 0.073 to 0.386 for the 10° tests, and 0.102 to 0.309 for the 1° tests. The sensor provided precise measurements of digit angles across 0–90° in multiple directions, enabling reliable clinical assessment, remote monitoring, and improved diagnosis, treatment, and rehabilitation for individuals with hand differences.

14 December 2018 in Medical Engineering & Physics
Verified
Journal Article
Closed access
LLLouise Le
Louise Le
AJAli Jabran
Ali Jabran
CPChris Peach
Chris Peach
LRLei Ren
Lei Ren
Plate-based treatment of proximal humerus fractures is associated with a high risk of complications such as screw perforation into glenohumeral joint. Smooth and threaded pegs were developed with the hope of minimising these risks. No consensus exists onto which threading profile achieves stiffest bone-plate construct. This study investigated the biomechanical effect of five percentages of threading on individual humeral head screws on a bone-plate construct. A finite element model simulating a two-part proximal humerus fracture treated with a Spatial Subchondral Support plate was developed and validated against in vitro biomechanical tests. The proportion of the humeral head screw length that was threaded was varied between 0%-100% in 25% increments. A 5-mm cantilever varus displacement was applied and the required load (F5) was calculated. Full (100%) threading achieved the stiffest construct for all six screws. Fully threading all smooth pegs at once increased F5 by 18%. Threading did not increase F5 equally in all screws. Inferior three plate screws exhibited a larger increase in stiffness than superior three. Most of the mechanical benefits of threading in inferior three screws can be achieved by using threaded pegs (50% threading) while the superior three screws need to be fully threaded. In practice, the smooth surface profile may also offer additional mechanical benefits if implanted with longer lengths and larger diameters. Threading is an effective way of increasing the varus bending stiffness of proximal humerus plates constructs.