Fabiano Gibson Daud Thulu

Mr. Fabiano Gibson Daud Thulu

Malawi Polytechnic
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2022 in Water
Verified
Journal Article
Open access
PDF file
RMRAYMOND SHAIBU MALIKULA
RAYMOND SHAIBU MALIKULA
CKChikumbusko Kaonga
Chikumbusko Kaonga
Harold Wilson Tumwitike MapomaHarold Wilson Tumwitike Mapoma
Harold Wilson Tumwitike Mapoma
FTFabiano Gibson Daud Thulu
Fabiano Gibson Daud Thulu
PCPetra Chiipa
Petra Chiipa
Heavy metals may cause acute and chronic toxic effects to humans and other organisms, hence the need to treat wastewater properly, as it contains these toxicants. This work aimed at assessing zinc, copper, cadmium, and chromium in water, soil, and plants that are irrigated with effluent from Manase and Soche Wastewater Treatment Plants (WWTPs) in Blantyre, Malawi. Atomic Absorption Spectrophotometry (AAS) was used to assess the heavy metals. Heavy Metal Health Risk Assessment (HMHRA) on plants (vegetables) around both WWTPs was also conducted. Average daily dose (ADD) and target hazard quotients (THQ) were used to assess HMHRA. Physicochemical parameters were determined using standard methods from American Public Health Association (APHA). The heavy metal ranges were below detection limit (BDL) to 6.94 mg/L in water, 0.0003 to 4.48 mg/kg in soil, and 3 to 32 mg/L in plants. The results revealed that plants irrigated with effluent from WWTP had high values of aforementioned metals exceeding the Malawi Standards and WHO permissible limits. Furthermore, the health risk assessment values showed that vegetables consumed for a long period of time from Manase WWTP were likely to cause adverse health effects as compared to those from Soche WWTP.

2 December 2021 in Journal of Nuclear Engineering
Verified
Journal Article
Open access
PDF file
FTFabiano Gibson Daud Thulu
Fabiano Gibson Daud Thulu
AEAyah Elshahat
Ayah Elshahat
MHMohamed H. M. Hassan
Mohamed H. M. Hassan
The safety performance of nuclear power plants (NPPs) is a very important factor in evaluating nuclear energy sustainability. Safety analysis of passive and active safety systems have a positive influence on reactor transient mitigation. One of the common transients is primary coolant leg rupture. This study focused on guillotine large break loss of coolant (LB-LOCA) in one of the reactor vessels, in which cold leg rupture occurred, after establishment of a steady-state condition for the VVER-1000. The reactor responses and performance of emergence core cooling systems (ECCSs) were investigated. The main safety margin considered during this simulation was to check the maximum value of the clad surface temperature, and it was then compared with the design licensing limit of 1474 K. The calculations of event progression used the engineering-level RELAP5/SCDAPSIM/MOD3.5 thermal-hydraulic program, which also provide a more detailed treatment of coolant system thermal hydraulics and core behavior. The obtained results show that actuation of ECCSs at their actuation set points provided core cooling by injecting water into the reactor pressure vessel, as expected. The peak cladding temperature did not overpass the licensing limit during this LB-LOCA transient. The primary pressure above the core decreased rapidly from 15.7 MPa to 1 MPa in less than 10 s, then stabilizes up to the end of transient. The fuel temperature decreased from 847 K to 378 K during the first 30 s of the transient time. The coolant leakage reduced from 9945 kg/s to approximately 461 kg/s during the first 190 s in the transient. Overall, the study shows that, within the design of the VVER-1000, safety systems of the have inherent robustness of containing guillotine LB-LOCA.

FTFabiano Gibson Daud Thulu
Fabiano Gibson Daud Thulu
DTDavid Tryson Tembo
David Tryson Tembo
RNRowland Nyirongo
Rowland Nyirongo
PMPatrick Joseph Cardinal Mzaza
Patrick Joseph Cardinal Mzaza
AKAllan Kamfosi
Allan Kamfosi
UCUpile Chitete-Mawenda
Upile Chitete-Mawenda
In this study, electric field and magnetic flux density pollution levels were measured in southern Africa, a case of Blantyre City in Malawi, between 2020 and 2021. Sixty short-term measurements were performed using Trifield Electro Magnetic Frequency meter model TF2 in 30 different locations. Five high-population-dense sampling points were selected from school campuses, hospitals, industrial areas, markets, residential areas, and within the commercial and business center (CBC) of Blantyre. Electric field and magnetic flux density pollution monitoring was conducted between 10:00–12:00 h and 17:00–19:00 h for short-range analysis. Short-range results show that the maximum measured electric field pollution were 249.24 mV/m and 207.85 mV/m between 10:00–12:00 and 17:00–19:00 respectively, which are below the public limits of 4200.00 mV/m for public exposure. Similarly, maximum short-range results for magnetic flux density were 0.073 G and 0.057 G between 10:00–12:00 and 17:00–19:00 respectively which are below the public limits of 2 G for public exposure. Both measured electric and magnetic flux density were compared with the International Commission on Non-Ionizing Radiation Protection (ICNIRP), World health organization (WHO), and Institute of electrical and electronics engineers (IEEE). It was determined that all measured values for both electric and magnetic flux density were smaller than set limits for non-ionizing radiation for both public and occupation health. More importantly, these background measurements establish a baseline for future changes to be compared against public safety.

1 May 2024 in Air
Verified
Journal Article
Open access
PDF file
CUConstance Chifuniro Utsale
Constance Chifuniro Utsale
CKChikumbusko Kaonga
Chikumbusko Kaonga
FTFabiano Gibson Daud Thulu
Fabiano Gibson Daud Thulu
IKIshmael Kosamu
Ishmael Kosamu
FTFred Thomson
Fred Thomson
HSHiroshi Sakugawa
Hiroshi Sakugawa
The increase in industrial activities has raised concerns regarding air quality in urban areas within Malawi. To assess the source apportionment of air quality parameters (AQPs) and noise levels, concentrations of AQPs (CO, TSP, PM 2.5, PM10) and noise levels were monitored at 15 sites in Makata, Limbe, Maselema, Chirimba, and Maone during dry and wet seasons, respectively. Active mobile multi-gas monitors and a Dylos DC1100 PRO Laser Particle Counter (2018 model) were used to monitor AQPs, while Integrated Sound Level Meters were used to measure noise levels. Monitoring and analysis were guided by the World Health Organization (WHO) and Malawi Standards (MS). A Positive Matrix Factorization (PMF) model was used to determine the source apportionment of AQPs, and matrix trajectories analysed air mass movement. In the wet season, the average concentration values of CO, TSP, PM10, and PM2.5 were 0.49 ± 0.65 mg/m3, 85.03 ± 62.18 µg/m3, 14.65 ± 8.13 µg/m3, and 11.52 ± 7.19 µg/m3, respectively. Dry season average concentration values increased to 1.31 ± 0.81 mg/m3, 99.86± 30.06 µg/m3, 24.35 ± 9.53 µg/m3, and 18.28 ± 7.14 µg/m3. Noise levels remained below public MS and WHO standards (85 dB). Positive correlations between AQPs and noise levels were observed, strengthening from weak in the dry season to moderately strong in the wet season. PMF analysis identified key factors influencing AQP accumulation, emphasizing the need for periodic sampling to monitor seasonal pollution trends, considering potential impacts on public health and environmental sustainability. Further studies should look at factors affecting the dynamics of PMF in Blantyre City.

18 January 2022 in Nuclear Science and Engineering
Verified
Journal Article
Closed access
FTFabiano Gibson Daud Thulu
Fabiano Gibson Daud Thulu
AEAyah Elshahat
Ayah Elshahat
MHMohamed Hassan
Mohamed Hassan
It is crucial to do safety evaluation of different postulated transient scenarios in actual nuclear power plants (NPPs). Some of the common analyzed scenarios are primary coolant tube rupture and station blackout (SBO). In this research, it was supposed that after establishment of a steady-state condition, an instantaneous guillotine large-break loss-of-coolant accident (LB-LOCA) of 850-mm inside diameter in one of the reactor vessel cold legs occurred, accompanied with SBO. The event progression and the variation of different reactor parameters like loop pressures, mass flow rates, fuel and clad temperature, injection rate of accumulators (ACCs), decay, and reactor power were investigated using the RELAP5/SCDAPSIM/MOD3.5 thermal-hydraulic program. The reactor consequences due to availability and unavailability of passive ACCs were compared. These kinds of analyses assist in estimating the time available to perform operator safety actions. This in turn aids in emergency planning and severe accident management. The results reveal that fuel damage decreased after the introduction of ACCs. Actuation of ACCs at their actuation setpoints provided core cooling by injecting water into the reactor core. However, ACCs alone are inadequate to contain long-term core cooling during a persistent LB-LOCA. The results obtained in the research were compared with MELCOR 2.1 and ASTEC V1.3, and a cohesive agreement was obtained. Therefore, RELAP5/SCDAPSIM/MOD3.5 is capable of modeling a LB-LOCA and SBO in VVER-1000, and it provides a significant analytical capability of safety systems for specialists in the field in NPP safety.