Jianzhong Wu

Jianzhong Wu


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Applied Energy
Verified
Journal Article
Open access
XLXuezhi Liu
Xuezhi Liu
JWJianzhong Wu
Jianzhong Wu
NJNick Jenkins
Nick Jenkins
ABAudrius Bagdanavicius
Audrius Bagdanavicius
Energy supply systems are usually considered as individual sub-systems with separate energy vectors. However, the use of Combined Heat and Power (CHP) units, heat pumps and electric boilers creates linkages between electricity and heat networks. Two combined analysis methods were developed to investigate the performance of electricity and heat networks as an integrated whole. These two methods were the decomposed and integrated electrical-hydraulic-thermal calculation techniques in the forms of power flow and simple optimal dispatch. Both methods were based on models of the electrical network, hydraulic and thermal circuits, and the coupling components, focusing on CHP units and circulation pumps. A case study of Barry Island electricity and district heating networks was conducted, showing how both electrical and heat demand in a self-sufficient system (no interconnection with external systems) were met using CHP units. The comparison showed that the integrated method requires less iteration than the decomposed method

1 February 2014 in Applied Energy
Verified
Journal Article
Open access
YMYunfei Mu
Yunfei Mu
JWJianzhong Wu
Jianzhong Wu
NJNick Jenkins
Nick Jenkins
HJHongjie Jia
Hongjie Jia
CWChengshan Wang
Chengshan Wang
A Spatial–Temporal model (STM) was developed to evaluate the impact of large scale deployment of plug-in electric vehicles (EVs) on urban distribution networks. The STM runs based on the integration of power system analysis and transportation analysis. Origin–Destination (OD) analysis from intelligent transportation research was used to model the EV mobility. Based on the EV technical and market information provided by the EU MERGE project and the output of OD analysis, a Monte Carlo simulation method was developed within the STM to obtain the EV charging load of each load busbar over time. The STM aims to facilitate power system evaluation and planning, and is able to provide both average values and probabilities of nodal bus voltages and branch loadings. The STM is able to identify the critical network components that will require to be upgraded. A high customer density urban network from the United Kingdom Generic Distribution System combined with geographic information was used as a test system. Two EV charging strategies, “dumb” charging and “smart” charging, were simulated and compared under different EV penetration levels (0%, 25% and 50%) to verify the effectiveness of STM

2 February 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
XJXun Jiang
Xun Jiang
YZYue Zhou
Yue Zhou
WMWenlong Ming
Wenlong Ming
PYPeng Yang
Peng Yang
JWJianzhong Wu
Jianzhong Wu
Soft open points (SOPs) are power electronic devices that are usually placed at normally open points of electricity distribution networks to provide flexible power control to the networks. This paper gives a comprehensive overview of both academic research and industrial practice on SOPs in electricity distribution networks. The topologies of SOPs as multi-functional power electronic devices are identified and compared, which include back-to-back voltage source converters, multi-terminal voltage source converters, unified power flow controllers, and direct AC-to-AC modular multilevel converters. The academic research is reviewed in three aspects, i.e., benefit quantification, control, and optimal siting and sizing of SOPs. The benefit quantification indices are categorized into feeder load balancing, voltage profile improvement, power losses reduction, three-phase balancing and DG hosting capacity enhancement. The control of SOPs is summarized as a three-level control structure, where the system-level and converter-level control are further discussed. For optimal siting and sizing of SOPs, problem formulation and solution methods are analyzed. Besides the academic research, practical industrial projects of SOPs worldwide are also summarized. Finally, opportunities of research and industrial application of SOPs are discussed.

1 May 2015 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MQMeysam Qadrdan
Meysam Qadrdan
MAMuditha Abeysekera
Muditha Abeysekera
MCModassar Chaudry
Modassar Chaudry
JWJianzhong Wu
Jianzhong Wu
NJNick Jenkins
Nick Jenkins

1 March 2016 in Applied Energy
Verified
Journal Article
Open access
WCWanyu Cao
Wanyu Cao
JWJianzhong Wu
Jianzhong Wu
NJNick Jenkins
Nick Jenkins
CWChengshan Wang
Chengshan Wang
TGTimothy Green
Timothy Green
Soft Open Points (SOPs) are power electronic devices installed in place of normally-open points in electrical power distribution networks. They are able to provide active power flow control, reactive power compensation and voltage regulation under normal network operating conditions, as well as fast fault isolation and supply restoration under abnormal conditions. A steady state analysis framework was developed to quantify the operational benefits of a distribution network with SOPs under normal network operating conditions. A generic power injection model was developed and used to determine the optimal SOP operation using an improved Powell’s Direct Set method. Physical limits and power losses of the SOP device (based on back to back voltage-source converters) were considered in the model. Distribution network reconfiguration algorithms, with and without SOPs, were developed and used to identify the benefits of using SOPs. Test results on a 33-bus distribution network compared the benefits of using SOPs, traditional network reconfiguration and the combination of both. The results showed that using only one SOP achieved a similar improvement in network operation compared to the case of using network reconfiguration with all branches equipped with remotely controlled switches. A combination of SOP control and network reconfiguration provided the optimal network operation

1 February 2016 in Applied Energy
Verified
Journal Article
Open access
WCWanyu Cao
Wanyu Cao
JWJianzhong Wu
Jianzhong Wu
NJNick Jenkins
Nick Jenkins
CWChengshan Wang
Chengshan Wang
TGTimothy Green
Timothy Green
Soft Open Points (SOPs) are power electronic devices installed in place of normally-open points in electrical power distribution networks. They are able to provide active power flow control, reactive power compensation and voltage regulation under normal network operating conditions, as well as fast fault isolation and supply restoration under abnormal conditions. Two control modes were developed for the operation of an SOP, using back-to-back voltage-source converters (VSCs). A power flow control mode with current control provides independent control of real and reactive power. A supply restoration mode with a voltage controller enables power supply to isolated loads due to network faults. The operating principle of the back-to-back VSCs based SOP was investigated under both normal and abnormal network operating conditions. Studies on a two-feeder medium-voltage distribution network showed the performance of the SOP under different network-operating conditions: normal, during a fault and post-fault supply restoration. During the change of network operating conditions, a mode switch method based on the phase locked loop controller was used to achieve the transitions between the two control modes. Hard transitions by a direct mode switching were noticed unfavourable, but seamless transitions were obtained by deploying a soft cold load pickup and voltage synchronization process