Santo Catapano

Prof. Dr. Santo Catapano

UNIFE
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 1997 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PBP. Baldissara
P. Baldissara
Santo CatapanoSanto Catapano
Santo Catapano
RSR. Scotti
R. Scotti

massimo corsalinimassimo corsalini
massimo corsalini
GBGiuseppe Barile
Giuseppe Barile
Santo CatapanoSanto Catapano
Santo Catapano
ACanna maria ciocia
anna maria ciocia
ACAssunta Casorelli
Assunta Casorelli
Saverio CapodiferroSaverio Capodiferro
Saverio Capodiferro
The number of patients undergoing a surgical resection of the maxilla for oncological reasons is constantly increasing, the most common complication of which remains the communication between oral and nasal cavities. On the basis of data arising from the literature regarding the treatment options of maxillary oncological post-surgical defects, obturator prosthesis remains the most used worldwide. We studied 25 patients (with at least 1-year follow up) rehabilitated by obturator prosthesis after maxillary resection leading to oro-nasal communication, providing data on the objective/subjective evaluation of such rehabilitation and mastication performance measured by a two-color chewing gum test. The type of defect was classified according to the classification system proposed by Aramany. Among the patients in our study, 72% rated a higher score for either stability and retention than for aesthetic appearance, as confirmed by the Kapur score rated by clinicians. The two-color chewing gum test shows similar results as only one patient had insufficient chewing function. Interestingly, we found no correlation between the masticatory function and residual denture, confirming that the maxillary obturator remains a predictable solution in such patients regardless of the anatomical alterations following surgery.

28 March 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
Francesco GrandeFrancesco Grande
Francesco Grande
FTFabio Tesini
Fabio Tesini
MPMario Cesare Pozzan
Mario Cesare Pozzan
Edoardo Mochi ZamperoliEdoardo Mochi Zamperoli
Edoardo Mochi Zamperoli
Massimo CarossaMassimo Carossa
Massimo Carossa
Santo CatapanoSanto Catapano
Santo Catapano
Today, two different types of CAD-CAM fabrication methods for complete denture bases are available besides the conventional protocols: a subtractive milling process from a prepolymerized block of polymethylmethacrylate and an additive manufacturing process that built the denture base using a light-cured liquid in a VAT-polymerization process. The aim of this study was to evaluate and to compare the accuracy and precision of denture prosthetic bases made with subtractive and additive manufacturing technologies and to compare them with a denture base with the conventional method in muffle. From the results obtained, 3D printing dentures show a statistically significant higher accuracy than milled prosthetic bases. Milled prosthetic bases have similar accuracy than conventional fabricated dentures.

20 May 2011 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
NMNicola Mobilio
Nicola Mobilio
ICI. Casetta
I. Casetta
ECE. Cesnik
E. Cesnik
Santo CatapanoSanto Catapano
Santo Catapano

11 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Santo CatapanoSanto Catapano
Santo Catapano
MFMattia Ferrari
Mattia Ferrari
NMNicola Mobilio
Nicola Mobilio
MMMarco Montanari
Marco Montanari
massimo corsalinimassimo corsalini
massimo corsalini
Francesco GrandeFrancesco Grande
Francesco Grande
Background: To compare the loss of preload in absence of loading and after a fixed number of cyclic loadings on 7-mm distal cantilever in two different connection systems using all-on-four prosthetic model. Methods: Two equal models of an edentulous mandible rehabilitated with all-on-four technique with two types of abutment system (MUA and OT-Bridge) supporting a hybrid prosthesis, were used. Initial torque values of the prosthetic fixing screw, after ten minutes from initial screw tightening and after 400,000 repeated loadings were registered using a mechanical torque gauge. Differences between initial and final torque values were reported for each anchoring system and the two systems were finally compared. Results: No statistically significant differences regarding the loss of preload between MUA and OT-Bridge system were found after 400,000 cyclic loadings; however, in MUA system it was found between anterior and posterior implant screws. A significant difference in preload loss was found only for MUA system comparing the initial screw torque to that measured after 10 min from the tightening in absence of cyclic loadings. Conclusions: Within the limits of the present study, MUA and OT-Bridge may be considered reliable prosthetic anchoring systems able to tolerate repeated cyclic occlusal loads on distal cantilever in all-on-four rehabilitation model without any significant loss of preload in screw tightening.

20 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
MPMario Cesare Pozzan
Mario Cesare Pozzan
Francesco GrandeFrancesco Grande
Francesco Grande
Edoardo Mochi ZamperoliEdoardo Mochi Zamperoli
Edoardo Mochi Zamperoli
FTFabio Tesini
Fabio Tesini
Massimo CarossaMassimo Carossa
Massimo Carossa
Santo CatapanoSanto Catapano
Santo Catapano
The aim of this study was to evaluate the stability of prosthetic screws after applying cyclic loadings in an “all-on-four” rehabilitation model with the OT Bridge system. The model was tested both with and without anterior screws. Four implant analogues following the “all-on-four” concept were inserted in an edentulous mandibular resin model. An OT Bridge system with a Cr–Co prosthetic framework was fabricated. Depending on the presence or absence of one or two anterior screws on the implant analogues, three groups were created, i.e., Gr.1: three tightening screws, Gr.2: two tightening screws, Control Group: four tightening screws. Each single group underwent subsequent 400,000 cyclic loads, simulating approximately a year of chewing by using a dynamometer machine. This cycle was repeated five times for each group, and preload loss values were evaluated on each prosthetic screw after each cycle. All the data obtained were analyzed by one-way ANOVA and Student’s t-test. No statistically significant differences after intragroup analysis were found. A statistically significant difference within the Gr.1 between the screws in positions 33 and 36, equal to 15.2% (p-value = 0.0176), was found. The OT Bridge seems a useful system to maintain the retention of a prosthesis during mechanical stress conditions even in the absence of one screw in an “all-on-four” rehabilitation. This could represent a good solution to solve the esthetic problem of the screw buccal access hole for fixed solutions.