Marco Montanari

Dr. Marco Montanari


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Santo CatapanoSanto Catapano
Santo Catapano
MFMattia Ferrari
Mattia Ferrari
NMNicola Mobilio
Nicola Mobilio
MMMarco Montanari
Marco Montanari
massimo corsalinimassimo corsalini
massimo corsalini
Francesco GrandeFrancesco Grande
Francesco Grande
Background: To compare the loss of preload in absence of loading and after a fixed number of cyclic loadings on 7-mm distal cantilever in two different connection systems using all-on-four prosthetic model. Methods: Two equal models of an edentulous mandible rehabilitated with all-on-four technique with two types of abutment system (MUA and OT-Bridge) supporting a hybrid prosthesis, were used. Initial torque values of the prosthetic fixing screw, after ten minutes from initial screw tightening and after 400,000 repeated loadings were registered using a mechanical torque gauge. Differences between initial and final torque values were reported for each anchoring system and the two systems were finally compared. Results: No statistically significant differences regarding the loss of preload between MUA and OT-Bridge system were found after 400,000 cyclic loadings; however, in MUA system it was found between anterior and posterior implant screws. A significant difference in preload loss was found only for MUA system comparing the initial screw torque to that measured after 10 min from the tightening in absence of cyclic loadings. Conclusions: Within the limits of the present study, MUA and OT-Bridge may be considered reliable prosthetic anchoring systems able to tolerate repeated cyclic occlusal loads on distal cantilever in all-on-four rehabilitation model without any significant loss of preload in screw tightening.

1 December 2020 in Prosthesis
Verified
Journal Article
Open access
PDF file
MMMarco Montanari
Marco Montanari
RSRoberto Scrascia
Roberto Scrascia
Gabriele CervinoGabriele Cervino
Gabriele Cervino
MPMASSIMO PASI
MASSIMO PASI
EFEmiliano Ferrari
Emiliano Ferrari
Marco TallaricoMarco Tallarico
Marco Tallarico
Purpose: To evaluate preliminary data on survival and success rates of immediately loaded, screw-retained, restorations delivered on lower arches using narrow and low-profile OT Equator abutments. Methods: This retrospective study analyzed data of patients rehabilitated with OT Bridge (fixed prosthetic system built on OT Equator) prosthetic concept from November 2017 to February 2019 in five different centers. Outcome measures were implant and prosthetic survival rates, biological and technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. Results: A total of 60 implants were inserted in 12 patients. Patients were followed for a mean period of 15.8 months (range 12–24). All the patients received OT Equator as intermediate abutments. Four out of 60 implants were connected to the prosthetic framework using only the Seeger system, without a screw. One year after loading, three implants failed (implant survival rate of 95.0%) in two patients. No prosthesis failed and no major biological and technical complications were experienced. One year after initial loading, the marginal bone level was 0.32 ± 0.2 mm. The OHIP before treatment was 87.7 ± 6.0. One year after treatment, OHIP was 23.6 ± 1.2. The difference was statistically significant (64.1 ± 7.2; p = 0.0000). One year after loading, 8.9% of the examined implant sites present positive bleeding on probing, while 5.8% of the implant sites presented plaque. Conclusions: The OT Equator abutments showed successful results when used to support mandible fixed dental prosthesis delivered on 4–6 implants. Whole prosthetic survival and success rates, high patient satisfaction, and good biological parameters were experienced one year after function. Further prospective studies are needed to confirm these preliminary results.

19 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
MMMarco Montanari
Marco Montanari
Luca FiorilloLuca Fiorillo
Luca Fiorillo
Gabriele CervinoGabriele Cervino
Gabriele Cervino
SSSergio Sambataro
Sergio Sambataro
AHAlan Scott Herford
Alan Scott Herford
Marco CicciùMarco Cicciù
Marco Cicciù
The objective of this study was to examine the effect of different conditions of simulated hydrostatic pulpal pressure on the μTBS of HEMA-based and HEMA-free dentin bonding agents (DBAs). The influence of dentin location (deep and superficial) on μTBS was also evaluated. Flat coronal dentin surfaces of extracted human molars were prepared. Three groups of resin-bonded specimens were exposed to different pulpal pressures. Pulpal pressure was maintained for 20 min for each group. A flowable resin composite was used for coronal build-up. The bonded teeth were sectioned and, after 24 h of water storage, stressed to failure using the microtensile tester (μTBS). Failed samples were analyzed by SEM inspection. HEMA-based DBAs were much more sensitive to pulpal pressure conditions than non-HEMA-containing DBAs. Pulpal pressure had a greater influence in deep dentin. The HEMA-free DBA was insensitive to the presence or absence of pulpal pressure condition. SEM inspection confirmed a relationship between the presence of voids inside the HEMA-based DBAs layer and the lower μTBS results. HEMA-based DBAs are more sensitive to pulpal pressure conditions than HEMA-free DBAs. Interestingly, HEMA-free DBA showed a greater number of water droplets at resin–dentin interface in all tested conditions.

19 March 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Claudio StacchiClaudio Stacchi
Claudio Stacchi
ARAntonio Rapani
Antonio Rapani
MMMarco Montanari
Marco Montanari
RMRebecca Martini
Rebecca Martini
Teresa LombardiTeresa Lombardi
Teresa Lombardi
Background: Plasma surface activation of dental implants has been proposed to enhance osseointegration by improving titanium surface chemistry. However, clinical data in humans remain limited. This randomized controlled trial aimed to assess the effect of vacuum plasma treatment on early implant stability in partially edentulous patients. Materials and Methods: In this single-blind, split-mouth randomized controlled trial, 24 patients requiring two contralateral implants were enrolled. Each patient received one plasma-treated implant and one untreated control implant. Vacuum plasma activation was performed immediately before insertion using a specific system (Plasma X Motion, MegaGen, Gyeongbuk, South Korea). Implant stability was assessed at placement and at 7, 14, 21, 28, 42, 60, and 90 days using resonance frequency analysis (Implant Stability Quotient, ISQ). Results: All 48 implants achieved successful osseointegration at 90 days, with no adverse events or complications. Mean insertion torque did not differ significantly between groups (p = 0.86). Both groups exhibited a typical initial reduction in stability, with the lowest ISQ values at 21 days. Plasma-treated implants showed a more favorable recovery pattern, with significantly higher ISQ values than controls at 60 and 90 days (p = 0.04 and p = 0.03, respectively). Nevertheless, the absolute difference in ISQ values between groups remained limited. Conclusion: Vacuum plasma activation of titanium implants may contribute to a more favorable early stability pattern, although both plasma-treated and untreated implants demonstrated predictable osseointegration outcomes. Further research with larger cohorts and longer follow-up is needed to fully assess the clinical significance of these findings.