Chengbiao Wan

Chengbiao Wan

Auto-generated profile, based on publicly available information

Chengbiao Wan

Huayin Ordnance Test Center, Huayin, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CWChengbiao Wan
Chengbiao Wan
HPHongfeng Pang
Hongfeng Pang
SMShaofeng Mou
Shaofeng Mou
HLHeng Li
Heng Li
MPMengchun Pan
Mengchun Pan
DYDaoning Yang
Daoning Yang
Magnetic anomaly detection (MAD) is a useful method for the detection of visually obscured ferromagnetic targets. However, when the prior information of the target signal is lacking or inaccurate, the performance of the traditional method based on orthonormal basis functions may degrade rapidly. Therefore, a novel detection method based on a parallel stochastic resonance (PSR) system is proposed, which is named the PSR detector. This method uses a PSR system to improve the signal-to-noise ratio (SNR) and then reveals anomaly signals by energy detector. Experimental results show that the detection probability of PSR detector reaches 70% even if input SNR is −3 dB and approximated to 100% if SNR is 0 dB under the false alarm probability (FAR) of 5%. In particular, the PSR detector provides a higher detection probability than the minimum entropy (ME) detector and a more balanced performance than the detector using a single stochastic resonance (SSR) system when the deterministic parameter of the target signal is lacking.

1 August 2017 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
CWChengbiao Wan
Chengbiao Wan
MPMengchun Pan
Mengchun Pan
QZQi Zhang
Qi Zhang
DCDixiang Chen
Dixiang Chen
HPHongfeng Pang
Hongfeng Pang
XZXuejun Zhu
Xuejun Zhu
In this work, the authors improve the magnetic anomaly detector by using Karhunen–Loeve expansion, for expanding the detection distance of visually obscured ferromagnetic object when the target signal is contaminated by coloured noise. In the detector, the orthonormal basis functions are modified by the autocorrelation function of geomagnetic noise, and the anomaly is detected by matched filtering. Compared with the traditional detector, simulation results show that the modified detector has better performance with coloured Gaussian noise; especially, the improvement is more evident when the noise exponent is bigger. The real geomagnetic noise is proved to be coloured and obey approximate Gaussian distribution by the measurements in experiment. Tests with this noise indicate that the proposed detector achieves an incremental detection probability of 0.1 – 0.2 in the case of low signal‐to‐noise ratio, which makes it more attractive in practice.

26 September 2018 in IEEE Geoscience and Remote Sensing Letters
Verified
Journal Article
Closed access
LYLiu Yang
Liu Yang
ZLZhongyan Liu
Zhongyan Liu
PMPan Mengchun
Pan Mengchun
ZQZhang Qi
Zhang Qi
CDChen Dixiang
Chen Dixiang
ZCZhuo Chen
Zhuo Chen
The decomposition of magnetic dipole signal in orthonormal basis functions (OBFs) is widely used in underwater target detection. Traditionally, only the squared sum of three coefficients is constructed as a magnetic anomaly detector, but the space distribution characteristic of coefficients is not fully utilized. In this letter, the constraint of coefficients is analyzed, and their space distribution constraint that located on an ellipsoid surface is obtained. Moreover, when the magnetization direction of target is nearly horizontal position, the constraint relationship of coefficients in the signal space can be compressed into an elliptical plane. Then, we project the decomposed coefficients of the measured signal onto the elliptical plane to further reduce the noise by about 1/3, and the squared sum of renewed coefficients is constructed as a detector for anomaly judgment. The simulation is conducted, compared with the traditional OBF method, and it can achieve an incremental detection probability of about 6% in the case of low signal-to-noise ratio.

27 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HPHongfeng Pang
Hongfeng Pang
MPMengchun Pan
Mengchun Pan
WQWei Qu
Wei Qu
LQLei Qiu
Lei Qiu
JYJun Yang
Jun Yang
XZXuejun Zhu
Xuejun Zhu
Magnetic sensor array is usually designed for object detection and localization, where sensor coordinate is required to be consistent. Misalignment angles between coordinates should be calculated and calibrated. A new calibration method is proposed in order to calibrate the misalignment error between host frame and sensors. Host platform frame and perpendicular platform are used to obtain misalignment angles of sensor array. Experiment results shows that it can estimate all angles of magnetic sensors and suppress misalignment error. Misalignment RMS error is a reduction from 1109.7 nT with 27.6 nT, which means 2.48% indeed, thus improving the remote sensing accuracy of array which is unified to host frame coordinate.

29 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HPHongfeng Pang
Hongfeng Pang
CWChengbiao Wan
Chengbiao Wan
SMShaofeng Mou
Shaofeng Mou
LWLu Wei
Lu Wei
HLHeng Li
Heng Li
DYDaoning Yang
Daoning Yang
Strap-down geomagnetic vector measurement system usually consists of three-axis magnetometer and inertial units, which is an effective device for measuring geomagnetic vector. However, its measurement accuracy is limited by disturbance of ferromagnetic material, measurement error of magnetometer and error caused by misalignment. Therefore, an integrated calibration method for strap-down geomagnetic vector measurement system is proposed. Firstly, the integrated error model is established, and a system with linear equations constraint is constructed by the measurements of inertial units, three-axis magnetometer and proton magnetometer; secondly, calibration parameters can be estimated by two-step least squares estimation (LSE); finally, geomagnetic vector measurement can be calibrated with these parameters in real time. Simulation results show that the relative errors between estimation and true parameters are less than 3%. Experimental results demonstrate that the errors of strap-down geomagnetic vector measurement system are suppressed effectively after integrated calibration, where North, Vertical and East component measurement errors are reduced from 809.2 nT, 300.0 nT, 776.8 nT to 14.8 nT (1.83% of uncalibrated value), 11.9 nT (3.97%), 32.5 nT (4.18%) respectively, and measurement accuracy of declination and inclination are achieved to 0.1°. Furthermore, the calibration error and time are least compared with traditional methods.

22 September 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RWRundong Wang
Rundong Wang
HPHongfeng Pang
Hongfeng Pang
WZWeigang Zhu
Weigang Zhu
CWChengbiao Wan
Chengbiao Wan
CZCong Zhou
Cong Zhou
YCYiming Cai
Yiming Cai
Magnetic anomaly detection (MAD) technology, which identifies concealed ferromagnetic targets by analyzing weak perturbations in the geomagnetic field, holds significant value in unexploded ordnance (UXO) identification, underwater target detection and related fields. To address the performance limitations of existing non-prior detection methods in low signal-to-noise ratio (SNR) scenarios, this study establishes a novel enhanced MAD framework through comparative analysis of probability density functions (PDFs) between reference signals and target signals, coupled with multi-metric similarity assessment, enabling reliable MAD in both single-sensor and dual-sensor configurations. Theoretical analysis and field experiments show that at SNR = -4 dB, the proposed method can improve the detection probability by 12.7% and 26.2%, respectively, relative to the parallel stochastic resonance (PSR) method and the minimum entropy detection (MED) method. This approach transcends the information dimensionality constraints of traditional entropy features, establishing a new paradigm for prior-free MAD in complex magnetic environments through multi-scale probability density feature extraction.