Zoltan Vilagosh

Dr. Zoltan Vilagosh

Swinburne University of Technology, Melbourne.

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2019 in Bioelectromagnetics
Verified
Journal Article
Closed access
PDF file
Zoltan VilagoshZoltan Vilagosh
Zoltan Vilagosh
ALAlireza Lajevardipour
Alireza Lajevardipour
AWAndrew Wood
Andrew Wood

19 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMeguya Ryu
Meguya Ryu
SNSoon Hock Ng
Soon Hock Ng
VIJAYAKUMAR ANANDVIJAYAKUMAR ANAND
VIJAYAKUMAR ANAND
SLStefan Lundgaard
Stefan Lundgaard
JHJingwen Hu
Jingwen Hu
JMJunko Morikawa
Junko Morikawa
Capabilities of the attenuated total reflection (ATR) at THz wavelengths for increased sub-surface depth characterisation of (bio-)materials are presented. The penetration depth of a THz evanescent wave in biological samples is dependent on the wavelength and temperature and can reach 0.1–0.5 mm depth, due to the strong refractive index change ∼0.4 of the ice-water transition; this is quite significant and important when studying biological samples. Technical challenges are discussed when using ATR for uneven, heterogeneous, high refractive index samples with the possibility of frustrated total internal reflection (a breakdown of the ATR reflection mode into transmission mode). Local field enhancements at the interface are discussed with numerical/analytical examples. Maxwell’s scaling is used to model the behaviour of absorber–scatterer inside the materials at the interface with the ATR prism for realistic complex refractive indices of bio-materials. The modality of ATR with a polarisation analysis is proposed, and its principle is illustrated, opening an invitation for its experimental validation. The sensitivity of the polarised ATR mode to the refractive index between the sample and ATR prism is numerically modelled and experimentally verified for background (air) spectra. The design principles of polarisation active optical elements and spectral filters are outlined. The results and proposed concepts are based on experimental conditions at the THz beamline of the Australian Synchrotron.

30 January 2020 in Scientific Reports
Verified
Journal Article
Open access
Zoltan VilagoshZoltan Vilagosh
Zoltan Vilagosh
ALAlireza Lajevardipour
Alireza Lajevardipour
AWAndrew Wood
Andrew Wood
There is increasing interest in applications which use the 30 to 90 GHz frequency range, including automotive radar, 5 G cellular networks and wireless local area links. This study investigated pulsed 30–90 GHz radiation penetration into the human ear canal and tympanic membrane using computational phantoms. Modelling involved 100 ps and 20 ps pulsed excitation at three angles: direct (orthogonal), 30° anterior, and 45° superior to the ear canal. The incident power flux density (PD) estimation was normalised to the International Commission on Non-Ionizing Radiation Protection (1998) standard for general population exposure of 10 Wm−2 and occupational exposure of 50 Wm−2. The PD, specific absorption rate (SAR) and temperature rise within the tympanic membrane was highly dependent on the incident angle of the radiation and frequency. Using a 30 GHz pulse directed orthogonally into the ear canal, the PD in the tympanic membrane was 0.2% of the original maximal signal intensity. The corresponding PD at 90 GHz was 13.8%. A temperature rise of 0.032° C (+20%, −50%) was noted within the tympanic membrane using the equivalent of an occupational standard exposure at 90 GHz. The central area of the tympanic membrane is exposed in a preferential way and local effects on small regions cannot be excluded. The authors strongly advocate further research into the effects of radiation above 60 GHz on the structures of the ear to assist the process of setting standards.

4 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Zoltan VilagoshZoltan Vilagosh
Zoltan Vilagosh
ALAlireza Lajevardipour
Alireza Lajevardipour
DADominique Appadoo
Dominique Appadoo
SNSoon Hock Ng
Soon Hock Ng
Saulius JuodkazisSaulius Juodkazis
Saulius Juodkazis
AWAndrew Wood
Andrew Wood
The penetration depth of an evanescent wave in Attenuated Total Reflection (ATR) is dependent on the wavelength of the radiation utilised. At THz frequencies, the penetration depth into biological tissues is in the order of 0.1 to 0.5 mm; rendered pig lard was used as a model sample in this study. A method for the direct measurement of the evanescent wave penetration depth is presented which allows for the estimation of the dispersion of the complex refractive index by using the reflection of the evanescent wave from varying sample depths. The method employs frustrated total internal reflection, and has been demonstrated by using the THz/Far-IR beamline at the Australian synchrotron, and modelled using finite difference time domain (FDTD) simulations.

28 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Negin ForoughimehrNegin Foroughimehr
Negin Foroughimehr
Zoltan VilagoshZoltan Vilagosh
Zoltan Vilagosh
Ali YavariAli Yavari
Ali Yavari
AWAndrew Wood
Andrew Wood
Due to increasing interest in imaging, industrial, and the development of wireless communication operating at THz frequencies, it is crucial to ascertain possible health impacts arising from exposure to THz radiation. This paper reports on the pilot study of transmittance and absorbance spectra of the porcine cornea following THz frequency irradiation at a synchrotron THz/Far-IR beamline. The exposure period was 4 hours. One cornea was exposed to the radiation, with a second cornea acting as a control. An Attenuated Total Reflection (ATR) apparatus was used, and the frequency range of 2.4 to 8 THz was selected to evaluate any changes. It was found that the synchrotron THz radiation intensities are too low to produce induced corneal injury, but may lead to subtle changes in the state of water. Our results suggest that THz spectroscopy is a promising modality for corneal tissue hydration sensing.

12 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Zoltan VilagoshZoltan Vilagosh
Zoltan Vilagosh
ALAlireza Lajevardipour
Alireza Lajevardipour
DADominique Appadoo
Dominique Appadoo
Saulius JuodkazisSaulius Juodkazis
Saulius Juodkazis
AWAndrew Wood
Andrew Wood
A novel method of investigating the temperature dependent variation of aspects of the complex refractive index n* in samples in the THz range using continuous, non-polarised, synchrotron radiation is presented. The method relies on the use of ATR apparatus, and retains the advantage of minimal sample preparation, which is a feature of ATR techniques. The method demonstrates a “proof of concept” of monitoring temperature reflectance whilst continuously heating or cooling samples by using a temperature variable Thermal Sample Stage. The method remains useful when the refractive index of the sample precludes attenuated total reflection study. This is demonstrated with the water reflectance experiments. The temperature dependent ATR reflectance of tissue-representative fats (lard and Lurpak® butter) was investigated with the novel approach. Both are within the ATR range of the diamond crystal in a “true” ATR mode. Lard showed no clear temperature variation between −15 °C and 24 °C at 0.7 to 1.15 THz or 1.70 to 2.25 THz. Lard can be regarded as having invariable, constant, dielectric properties within mixtures when biological substances are being assessed for temperature dependent dielectric variation within the stated THz ranges. Lurpak® butter (water content 14.7%) displayed temperature dependent reflected signal intensity features with a steady decline in reflectivity with increasing temperature. This is in line with the temperature-dependent behaviour of liquid water. There is no rapid change in reflected signal intensity even at −20 °C, suggesting that emulsified water retains liquid-water-like THz properties at freezing temperatures.