Navideh Abbasnezhad

Dr. Navideh Abbasnezhad

Arts et Metiers Institute of Technology, CNAM, LIFSE, HESAM University, 75013 Paris, France
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Bioactive Materials
Verified
Journal Article
Open access
Abbas TcharkhtchiAbbas Tcharkhtchi
Abbas Tcharkhtchi
Navideh AbbasnezhadNavideh Abbasnezhad
Navideh Abbasnezhad
MSM. Zarbini Seydani
M. Zarbini Seydani
Nader ZirakNader Zirak
Nader Zirak
Sedigheh FarzanehSedigheh Farzaneh
Sedigheh Farzaneh
Mohammadali ShirinbayanMohammadali Shirinbayan
Mohammadali Shirinbayan
The masks have always been mentioned as an effective tool against environmental threats. They are considered as protective equipment to preserve the respiratory system against the non-desirable air droplets and aerosols such as the viral or pollution particles. The aerosols can be pollution existence in the air, or the infectious airborne viruses initiated from the sneezing, coughing of the infected people. The filtration efficiency of the different masks against these aerosols are not the same, as the particles have different sizes, shapes, and properties. Therefore, the challenge is to fabricate the filtration masks with higher efficiency to decrease the penetration percentage at the nastiest conditions. To achieve this concept, knowledge about the mechanisms of the penetration of the aerosols through the masks at different effective environmental conditions is necessary. In this paper, the literature about the different kinds of face masks and respiratory masks, common cases of their application, and the advantages and disadvantages of them in this regard have been reviewed. Moreover, the related mechanisms of the penetration of the aerosols through the masks are discussed. The environmental conditions affecting the penetration as well as the quality of the fabrication are studied. Finally, special attention was given to the numerical simulation related to the different existing mechanisms.

17 October 2020 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
Navideh AbbasnezhadNavideh Abbasnezhad
Navideh Abbasnezhad
NZNader Zirak
Nader Zirak
MSMohammadali Shirinbayan
Mohammadali Shirinbayan
SKSmaine Kouidri
Smaine Kouidri
Erfan SalahinejadErfan Salahinejad
Erfan Salahinejad
FBFarid Bakir
Farid Bakir

1 April 2018 in International Journal of Fatigue
Verified
Journal Article
Closed access
Navideh AbbasnezhadNavideh Abbasnezhad
Navideh Abbasnezhad
AKA. Khavandi
A. Khavandi
JFJ. Fitoussi
J. Fitoussi
HAH. Arabi
H. Arabi
Mohammadali ShirinbayanMohammadali Shirinbayan
Mohammadali Shirinbayan
ATA. Tcharkhtchi
A. Tcharkhtchi

1 December 2017 in Composites Part B: Engineering
Verified
Journal Article
Closed access
Mohammadali ShirinbayanMohammadali Shirinbayan
Mohammadali Shirinbayan
JFJ. Fitoussi
J. Fitoussi
Navideh AbbasnezhadNavideh Abbasnezhad
Navideh Abbasnezhad
FMF. Meraghni
F. Meraghni
BSB. Surowiec
B. Surowiec
ATA. Tcharkhtchi
A. Tcharkhtchi

10 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Navideh AbbasnezhadNavideh Abbasnezhad
Navideh Abbasnezhad
MKMohamed KEBDANI
Mohamed KEBDANI
Mohammadali ShirinbayanMohammadali Shirinbayan
Mohammadali Shirinbayan
SCStéphane Champmartin
Stéphane Champmartin
Abbas TcharkhtchiAbbas Tcharkhtchi
Abbas Tcharkhtchi
Farid BakirFarid Bakir
Farid Bakir
In this study, we present a method for prediction of the drug-release profile based on the physical mechanisms that can intervene in drug release from a drug-carrier. The application presented here incorporates the effects of drug concentration and Reynolds number defining the circulating flow in the testing vein. The experimental data used relate to the release of diclofenac from samples of non-degradable polyurethane subjected to static and continuous flow. This case includes simultaneously three mechanisms: burst-release, diffusion and osmotic pressure, identified beforehand here as being able to contribute to the drug liberation. For this purpose, authors coded the Sequential Quadratic Programming Algorithm to solve the problem of non-linear optimization. The experimental data used to develop the mathematical model obtained from release studies carried out in water solution at 37 °C, for three concentrations of diclofenac and two water flow rates. We discuss the contribution of mechanisms and kinetics by considering two aforementioned parameters and, following that, we obtain the specific-model and compare the calculated results with the experimental results for the reserved cases. The results showed that drug percentage mostly affect the burst release, however flow rate has affected the osmotic release. In addition, release kinetics of all the mechanisms have increased by increasing the values of two considered parameters.

5 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Navideh AbbasnezhadNavideh Abbasnezhad
Navideh Abbasnezhad
Nader ZirakNader Zirak
Nader Zirak
SCStéphane Champmartin
Stéphane Champmartin
Mohammadali ShirinbayanMohammadali Shirinbayan
Mohammadali Shirinbayan
Farid BakirFarid Bakir
Farid Bakir
The drug release profile of drug-eluting stents (DESs) is affected by a number of factors, including the formulation, design, and physicochemical properties of the utilized material. DES has been around for twenty years and despite its widespread clinical use, and efficacy in lowering the rate of target lesion restenosis, it still requires additional development to reduce side effects and provide long-term clinical stability. Unfortunately, for analyzing these implants, there is still no globally accepted in vitro test method. This is owing to the stent’s complexity as well as the dynamic arterial compartments of the blood and vascular wall. The former is the source of numerous biological, chemical, and physical mechanisms that are more commonly observed in tissue, lumen, and DES. As a result, universalizing bio-relevant apparatus, suitable for liberation testing of such complex implants is difficult. This article aims to provide a comprehensive review of the methods used for in vitro release testing of DESs. Aspects related to the correlation of the release profiles in the cases of in vitro and in vivo are also addressed.