Alessandra Scarton

Prof. Alessandra Scarton

Università degli Studi di Verona
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2023 in Organic Electronics
Verified
Journal Article
Open access
Mattia PetrelliMattia Petrelli
Mattia Petrelli
BSBajramshahe Shkodra
Bajramshahe Shkodra
AFAniello Falco
Aniello Falco
MAMartina Aurora Costa Angeli
Martina Aurora Costa Angeli
SVSahira Vasquez
Sahira Vasquez
LPLuisa Petti
Luisa Petti

1 November 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
LFLuca Ferrari
Luca Ferrari
GBGianluca Bochicchio
Gianluca Bochicchio
ABAlberto Bottari
Alberto Bottari
Alessandra ScartonAlessandra Scarton
Alessandra Scarton
FLFrancesco Lucertini
Francesco Lucertini
SPSilvia Pogliaghi
Silvia Pogliaghi
Inertial Motor sensors (IMUs) are valid instruments for measuring postural sway but their ability to detect changes derived from visual deprivation in healthy older adults requires further investigations. We examined the validity and relationship of IMU sensor-derived postural sway measures compared to force plates for different eye conditions in healthy older adults (32 females, 33 males). We compared the relationship of the center of mass and center of pressure (CoM and CoP)-derived total length, root means square (RMS) distance, mean velocity, and 95% confidence interval ellipse area (95% CI ellipse area). In addition, we examined the relationship of the IMU sensor in discriminating between open- (EO) and closed-eye (EC) conditions compared to the force plate. A significant effect of the instruments and eye conditions was found for almost all the variables. Overall, EO and EC variables within (force plate r, from 0.38 to 0.78; IMU sensor r, from 0.36 to 0.69) as well as between (r from 0.50 to 0.88) instruments were moderately to strongly correlated. The EC:EO ratios of RMS distance and 95% CI ellipse area were not different between instruments, while there were significant differences between total length (p = 0.973) and mean velocity (p = 0.703). The ratios’ correlation coefficients between instruments ranged from moderate (r = 0.65) to strong (r = 0.87). The IMU sensor offers an affordable, valid alternative to a force plate for objective, postural sway assessment.

16 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GBGianluca Bochicchio
Gianluca Bochicchio
LFLuca Ferrari
Luca Ferrari
ABAlberto Bottari
Alberto Bottari
FLFrancesco Lucertini
Francesco Lucertini
Alessandra ScartonAlessandra Scarton
Alessandra Scarton
SPSilvia Pogliaghi
Silvia Pogliaghi
The 5-Sit-to-stand test (5STS) is widely used to estimate lower limb muscle power (MP). An Inertial Measurement Unit (IMU) could be used to obtain objective, accurate and automatic measures of lower limb MP. In 62 older adults (30 F, 66 ± 6 years) we compared (paired t-test, Pearson’s correlation coefficient, and Bland-Altman analysis) IMU-based estimates of total trial time (totT), mean concentric time (McT), velocity (McV), force (McF), and MP against laboratory equipment (Lab). While significantly different, Lab vs. IMU measures of totT (8.97 ± 2.44 vs. 8.86 ± 2.45 s, p = 0.003), McV (0.35 ± 0.09 vs. 0.27 ± 0.10 m∙s−1, p < 0.001), McF (673.13 ± 146.43 vs. 653.41 ± 144.58 N, p < 0.001) and MP (233.00 ± 70.83 vs. 174.84 ± 71.16 W, p < 0.001) had a very large to extremely large correlation (r = 0.99, r = 0.93, and r = 0.97 r = 0.76 and r = 0.79, respectively, for totT, McT, McF, McV and MP). Bland–Altman analysis showed a small, significant bias and good precision for all the variables, but McT. A sensor-based 5STS evaluation appears to be a promising objective and digitalized measure of MP. This approach could offer a practical alternative to the gold standard methods used to measure MP.

15 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LFLuca Ferrari
Luca Ferrari
GBGianluca Bochicchio
Gianluca Bochicchio
ABAlberto Bottari
Alberto Bottari
FLFrancesco Lucertini
Francesco Lucertini
Alessandra ScartonAlessandra Scarton
Alessandra Scarton
SPSilvia Pogliaghi
Silvia Pogliaghi
The 5-Sit-to-stand test (5STS) is used for lower limb muscle power (MP) determination in field/clinical setting. From the time taken to perform five standing movements and three partially verified assumptions (vertical displacement, mean concentric time, and mean force), MP is estimated as the body’s vertical velocity x force. By comparison with a gold standard, laboratory approach (motion capture system and force plate), we aimed to: (1) verify the assumptions; (2) assess the accuracy of the field-estimated MP (MPfield); (3) develop and validate an optimized estimation (MPfield-opt). In 63 older adults (67 ± 6 years), we compared: (i) estimated and measured assumptions (2-WAY RM ANOVA), (ii) MPfield and MPfield-opt with the reference/laboratory method (MPlab) (2-WAY RM ANOVA, Pearson’s correlation coefficient (r), Bland-Altman analysis). There was a significant difference between estimated and measured assumptions (p < 0.001). Following the implementation of the optimized assumptions, MPfield-opt (205.1 ± 55.3 W) was not significantly different from Mlab (199.5 ± 57.9 W), with a high correlation (r = 0.86, p < 0.001) and a non-significant bias (5.64 W, p = 0.537). Provided that corrected assumptions are used, 5STS field test is confirmed a valid time- and cost-effective field method for the monitoring of lower limbs MP, a valuable index of health status in aging.

23 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LSLaura Simoni
Laura Simoni
Alessandra ScartonAlessandra Scarton
Alessandra Scarton
CMClaudio MACCHI
Claudio MACCHI
FGFederico Gori
Federico Gori
GPGuido Pasquini
Guido Pasquini
SPSilvia Pogliaghi
Silvia Pogliaghi
Quantitative and qualitative running gait analysis allows the early identification and the longitudinal monitoring of gait abnormalities linked to running-related injuries. A promising calibration- and marker-less video sensor-based technology (i.e., Graal), recently validated for walking gait, may also offer a time- and cost-efficient alternative to the gold-standard methods for running. This study aim was to ascertain the validity of an improved version of Graal for quantitative and qualitative analysis of running. In 33 healthy recreational runners (mean age 41 years), treadmill running at self-selected submaximal speed was simultaneously evaluated by a validated photosensor system (i.e., Optogait—the reference methodology) and by the video analysis of a posterior 30-fps video of the runner through the optimized version of Graal. Graal is video analysis software that provides a spectral analysis of the brightness over time for each pixel of the video, in order to identify its frequency contents. The two main frequencies of variation of the pixel’s brightness (i.e., F1 and F2) correspond to the two most important frequencies of gait (i.e., stride frequency and cadence). The Optogait system recorded step length, cadence, and its variability (vCAD, a traditional index of gait quality). Graal provided a direct measurement of F2 (reflecting cadence), an indirect measure of step length, and two indexes of global gait quality (harmony and synchrony index). The correspondence between quantitative indexes (Cadence vs. F2 and step length vs. Graal step length) was tested via paired t-test, correlations, and Bland–Altman plots. The relationship between qualitative indexes (vCAD vs. Harmony and Synchrony Index) was investigated by correlation analysis. Cadence and step length were, respectively, not significantly different from and highly correlated with F2 (1.41 Hz ± 0.09 Hz vs. 1.42 Hz ± 0.08 Hz, p = 0.25, r2 = 0.81) and Graal step length (104.70 cm ± 013.27 cm vs. 107.56 cm ± 13.67 cm, p = 0.55, r2 = 0.98). Bland–Altman tests confirmed a non-significant bias and small imprecision between methods for both parameters. The vCAD was 1.84% ± 0.66%, and it was significantly correlated with neither the Harmony nor the Synchrony Index (0.21 ± 0.03, p = 0.92, r2 = 0.00038; 0.21 ± 0.96, p = 0.87, r2 = 0.00122). These findings confirm the validity of the optimized version of Graal for the measurement of quantitative indexes of gait. Hence, Graal constitutes an extremely time- and cost-efficient tool suitable for quantitative analysis of running. However, its validity for qualitative running gait analysis remains inconclusive and will require further evaluation in a wider range of absolute and relative running intensities in different individuals.

7 August 2023 in IEEE Journal on Flexible Electronics
Verified
Journal Article
Open access
Mattia PetrelliMattia Petrelli
Mattia Petrelli
BSBajramshahe Shkodra
Bajramshahe Shkodra
AFAniello Falco
Aniello Falco
MAMartina Aurora Costa Angeli
Martina Aurora Costa Angeli
SVSahira Vasquez
Sahira Vasquez
LPLuisa Petti
Luisa Petti
Electrolyte-gated field-effect transistors (EG-FETs) are widely used in the growing field of biochemical sensing applications, due to their manifold advantages, such as large specific capacitance, low operating voltage, and intrinsic signal amplification. In this work, carbon nanotube EG-FET (EG-CNTFET)-based sensors for ammonium (NH + 4 ) detection are reported. The active semiconducting single-walled carbon nanotube (CNTs) layer was manufactured through a cost-effective and scalable spray deposition technique. To achieve high-quality semiconducting networks, the CNT ink was optimized. Atomic force microscopy analysis was used to optimize the CNT concentration and significantly reduce the post-treatment time from the previously reported 12 h to 1 h. The optimized ink was then used to fabricate EG-CNTFETs first on standard rigid Si/SiO 2 substrate and then on flexible polyimide foils. Both devices showed typical p-type behavior with an on-off ratio in the order of magnitude of 1×10 3 A/A. Furthermore, as proof of concept, we demonstrated the detection of the NH + 4 ions with EG-CNTFETs fabricated on a flexible substrate and functionalized with nonactin ion-selective membrane. The calibration curve of the fabricated sensors showed a linear detection range for ammonium from 0.01mM to 10mM, covering the entire range of physiological concentrations of interest, with an average sensitivity of 0.346 μA/decade and a 94.35% coefficient of determination.