Petr Mlynek

Dr. Petr Mlynek


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
PMPavel Masek
Pavel Masek
JMJan Mašek
Jan Mašek
PFPetr Frantik
Petr Frantik
RFRadek Fujdiak
Radek Fujdiak
Aleksandr OmetovAleksandr Ometov
Aleksandr Ometov
Jiří MišurecJiří Mišurec
Jiří Mišurec
The unprecedented growth of today’s cities together with increased population mobility are fueling the avalanche in the numbers of vehicles on the roads. This development led to the new challenges for the traffic management, including the mitigation of road congestion, accidents, and air pollution. Over the last decade, researchers have been focusing their efforts on leveraging the recent advances in sensing, communications, and dynamic adaptive technologies to prepare the deployed road traffic management systems (TMS) for resolving these important challenges in future smart cities. However, the existing solutions may still be insufficient to construct a reliable and secure TMS that is capable of handling the anticipated influx of the population and vehicles in urban areas. Along these lines, this work systematically outlines a perspective on a novel modular environment for traffic modeling, which allows to recreate the examined road networks in their full resemblance. Our developed solution is targeted to incorporate the progress in the Internet of Things (IoT) technologies, where low-power, embedded devices integrate as part of a next-generation TMS. To mimic the real traffic conditions, we recreated and evaluated a practical traffic scenario built after a complex road intersection within a large European city.

1 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PMPetr Mlynek
Petr Mlynek
MRMartin Rusz
Martin Rusz
LBLukáš Benešl
Lukáš Benešl
JSJan Slacik
Jan Slacik
PMPetr Musil
Petr Musil
Broadband Power Line communication is considered as one of possible communication technologies for the buildings communication infrastructure in the concept of Smart Building. The possible applications where BPL (Broadband over Power Lines) solution can be used for communication in the concept of Smart Building are Power Quality (PQ) measurement, Electric Vehicle or Micro Grids and Distribution Generation (DG). This article should help to determine clear performance possibilities of BPL for an implementation in Smart Building especially due to a large amount of overhead caused by cybersecurity and the protocol overhead. The possibilities of BPL were measured with five different BPL solutions. The results show a sufficient throughput on the application layer for Smart Building application, because, in the literature, various throughput limits are introduced. According to related work, there are missing measurements on the application layer for laboratory conditions as well as compared with real field measurements. In this article, we also exploit our novel idea of a broadband PLC (Power Line Communication) modem integrated into an electrical outlet.

1 January 2016 in Advances in Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
PMPetr Mlynek
Petr Mlynek
ZEYNEP HASIRCI TUĞCUZEYNEP HASIRCI TUĞCU
ZEYNEP HASIRCI TUĞCU
Jiří MišurecJiří Mišurec
Jiří Mišurec
RFRadek Fujdiak
Radek Fujdiak
The paper deals with simulations of power line channel transfer functions in Network Simulator version 3. Firstly, an empirical model and calculation of the channel transfer function are given to reflect the necessity of channel transfer function for Power Line Communication system design. The framework for Power Line Communication in Network Simulator version 3 and then the necessary extension implementation are introduced. Other simulators are also mentioned. Secondly, various scenarios were implemented for the analysis and simulation of power line channel transfer functions. New scenarios for large topologies and for different approaches to calculate primary parameters were created. In the simulations, various kinds of topologies are considered for an analysis of the power line transfer function. The simulation part also focuses on the simulation of channel transfer function where the time- and frequency-selective impedances are considered. Finally, the last part focuses on measurements and a comparison of the simulation results with real measurements are given

1 April 2015 in Measurement Science Review
Verified
Journal Article
Open access
PMPetr Mlynek
Petr Mlynek
Jiří MišurecJiří Mišurec
Jiří Mišurec
MKMarek Koutný
Marek Koutný
RFRadek Fujdiak
Radek Fujdiak
TJT. Jedlicka
T. Jedlicka
The article describes a way of evaluating the power line channel frequency response and input impedance by means of the linear time-invariant (LTI) power line generator. Two possible methods are introduced for the calculation of primary parameters: the first method depends on the physical realization and physical dimension of the cable, and the second method is derived from the data provided by typical electrical cable manufacturers. Based on these methods, a comparison of transfer functions was made. This is followed by measurement evaluation and numerical verification on a simple topology

15 April 2015 in Elektronika ir Elektrotechnika
Verified
Journal Article
Closed access
PDF file
PMPetr Mlynek
Petr Mlynek
Jiří MišurecJiří Mišurec
Jiří Mišurec
RFRadek Fujdiak
Radek Fujdiak
ZKZ. Kolka
Z. Kolka
LPL. Pospichal
L. Pospichal
In this paper, the radio wireless communication and the narrowband power line communication are analysed, simulated and experimentally verified for Smart Metering systems. This is followed by the proposal of a heterogeneous network, which consists of wireless radio transmission and narrowband power line communication (PLC). In rural and remote areas, due to the low population density and the poor familiarity with new technologies, the heterogeneous radio-PLC network offers a solution for smart grid and smart metering applicationsDOI: http://dx.doi.org/10.5755/j01.eee.21.2.115015

12 April 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPetr Mlynek
Petr Mlynek
Jiří MišurecJiří Mišurec
Jiří Mišurec
PSPavel Silhavy
Pavel Silhavy
RFRadek Fujdiak
Radek Fujdiak
JSJan Slacik
Jan Slacik
ZEYNEP HASIRCI TUĞCUZEYNEP HASIRCI TUĞCU
ZEYNEP HASIRCI TUĞCU
Building real Smart Metering and Smart Grid networks is very expensive and time-consuming and also it is impossible to install different technologies in the same environment only for comparison. Therefore, simulation and experimental pilot measurements are an easy, economical, and time-affordable solution for a first comparison and evaluation of different technologies and solutions. The local area networks (LAN) are the core of Smart Metering and Smart Grid networks. The two predominant technologies are mostly sufficient for LAN networks, Power Line Communication (PLC), and radio frequency (RF) solutions. For PLC it is hard to allow prediction of the behaviour. Performance assessment for point-to-point connection is easy, but for complex PLC networks with repeaters it is quite expensive. Therefore, a simulation is an easy, fast, and cheap solution for understanding the grid configuration, influence of particular topological components, and performance possibilities. Simulation results can, thus, provide material for the design of a telecommunication infrastructure for Smart Metering. This paper presents results of such a simulation study. It is based on realistic PLC channel model implementation in Network Simulator 3, our modification and extension of this implementation for our use case scenario. It uses Shannon’s formula to calculate theoretical maximum channel capacity. In particular, it provides channel capacity and achievable distances of broadband PLC (BB-PLC). In this article we also exploit our novel idea of simple performance assessment of broadband PLC communication via simulation. It is supposed to be used to understand, evaluate, and test the grid configuration before deployment.