Malte Storm

Dr. Malte Storm


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
CBCarles Bosch
Carles Bosch
TATobias Ackels
Tobias Ackels
APAlexandra Pacureanu
Alexandra Pacureanu
YZYuxin Zhang
Yuxin Zhang
CPChristopher J. Peddie
Christopher J. Peddie
ASAndreas Schaefer
Andreas Schaefer
Understanding the function of biological tissues requires a coordinated study of physiology and structure, exploring volumes that contain complete functional units at a detail that resolves the relevant features. Here, we introduce an approach to address this challenge: Mouse brain tissue sections containing a region where function was recorded using in vivo 2-photon calcium imaging were stained, dehydrated, resin-embedded and imaged with synchrotron X-ray computed tomography with propagation-based phase contrast (SXRT). SXRT provided context at subcellular detail, and could be followed by targeted acquisition of multiple volumes using serial block-face electron microscopy (SBEM). In the olfactory bulb, combining SXRT and SBEM enabled disambiguation of in vivo-assigned regions of interest. In the hippocampus, we found that superficial pyramidal neurons in CA1a displayed a larger density of spine apparati than deeper ones. Altogether, this approach can enable a functional and structural investigation of subcellular features in the context of cells and tissues.

30 July 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SFSilja Flenner
Silja Flenner
MSMalte Storm
Malte Storm
AKAdam Kubec
Adam Kubec
ELElena Longo
Elena Longo
FDFlorian Döring
Florian Döring
IGImke Greving
Imke Greving
Hard X-ray nanotomography enables 3D investigations of a wide range of samples with high resolution (<100 nm) with both synchrotron-based and laboratory-based setups. However, the advantage of synchrotron-based setups is the high flux, enabling time resolution, which cannot be achieved at laboratory sources. Here, the nanotomography setup at the imaging beamline P05 at PETRA III is presented, which offers high time resolution not only in absorption but for the first time also in Zernike phase contrast. Two test samples are used to evaluate the image quality in both contrast modalities based on the quantitative analysis of contrast-to-noise ratio (CNR) and spatial resolution. High-quality scans can be recorded in 15 min and fast scans down to 3 min are also possible without significant loss of image quality. At scan times well below 3 min, the CNR values decrease significantly and classical image-filtering techniques reach their limitation. A machine-learning approach shows promising results, enabling acquisition of a full tomography in only 6 s. Overall, the transmission X-ray microscopy instrument offers high temporal resolution in absorption and Zernike phase contrast, enabling in situ experiments at the beamline.

30 November 2020 in Optics Express
Verified
Journal Article
Open access
SFSilja Flenner
Silja Flenner
AKAdam Kubec
Adam Kubec
CDChristian David
Christian David
MSMalte Storm
Malte Storm
CSClemens F. Schaber
Clemens F. Schaber
JHJohannes Hagemann
Johannes Hagemann
X-ray phase contrast nanotomography enables imaging of a wide range of samples with high spatial resolution in 3D. Near-field holography, as one of the major phase contrast techniques, is often implemented using X-ray optics such as Kirkpatrick-Baez mirrors, waveguides and compound refractive lenses. However, these optics are often tailor-made for a specific beamline and challenging to implement and align. Here, we present a near-field holography setup based on Fresnel zone plates which is fast and easy to align and provides a smooth illumination and flat field. The imaging quality of different types of Fresnel zone plates is compared in terms of the flat-field quality, the achievable resolution and exposure efficiency i.e. the photons arriving at the detector. Overall, this setup is capable of imaging different types of samples at high spatial resolution of below 100 nm in 3D with access to the quantitative phase information.

1 June 2021 in Materials Today Communications
Verified
Journal Article
Open access
CBCyril Besnard
Cyril Besnard
RHRobert A. Harper
Robert A. Harper
TMThomas Moxham
Thomas Moxham
JJJonathan D. James
Jonathan D. James
MSMalte Storm
Malte Storm
Alexander KorsunskyAlexander Korsunsky
Alexander Korsunsky

1 April 2021 in Combustion and Flame
Verified
Journal Article
Closed access
GPG.R. Parker
G.R. Parker
DED.S. Eastwood
D.S. Eastwood
MSMalte Storm
Malte Storm
KVK. Vitharana
K. Vitharana
EHE.M. Heatwole
E.M. Heatwole
NBN.K. Bourne
N.K. Bourne

1 December 2021 in Bioactive Materials
Verified
Journal Article
Open access
BZBerit Zeller-Plumhoff
Berit Zeller-Plumhoff
DLDaniel Laipple
Daniel Laipple
HSHanna Slominska
Hanna Slominska
KIKamila Iskhakova
Kamila Iskhakova
ELElena Longo
Elena Longo
RWRegine Willumeit
Regine Willumeit
Magnesium is attractive for the application as a temporary bone implant due to its inherent biodegradability, non-toxicity and suitable mechanical properties. The degradation process of magnesium in physiological environments is complex and is thought to be a diffusion-limited transport problem. We use a multi-scale imaging approach using micro computed tomography and transmission X-ray microscopy (TXM) at resolutions below 40 nm. Thus, we are able to evaluate the nanoporosity of the degradation layer and infer its impact on the degradation process of pure magnesium in two physiological solutions. Magnesium samples were degraded in simulated body fluid (SBF) or Dulbecco's modified Eagle's medium (DMEM) with 10% fetal bovine serum (FBS) for one to four weeks. TXM reveals the three-dimensional interconnected pore network within the degradation layer for both solutions. The pore network morphology and degradation layer composition are similar for all samples. By contrast, the degradation layer thickness in samples degraded in SBF was significantly higher and more inhomogeneous than in DMEM+10%FBS. Distinct features could be observed within the degradation layer of samples degraded in SBF, suggesting the formation of microgalvanic cells, which are not present in samples degraded in DMEM+10%FBS. The results suggest that the nanoporosity of the degradation layer and the resulting ion diffusion processes therein have a limited influence on the overall degradation process. This indicates that the influence of organic components on the dampening of the degradation rate by the suppression of microgalvanic degradation is much greater in the present study.