Jean-Yves Hihn

Prof. Dr. Jean-Yves Hihn

Institut UTINAM UMR 6213 CNRS, Université de Bourgogne Franche Comté, 16 route de Gray F25030, Besançon Cedex, France

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2016 in Chemical Science
Verified
Journal Article
Open access
PDF file
Miguel Aller PelliteroMiguel Aller Pellitero
Miguel Aller Pellitero
ABAnton Guimerà Brunet
Anton Guimerà Brunet
Maria KitsaraMaria Kitsara
Maria Kitsara
RSRosa Villa Sanz
Rosa Villa Sanz
CRCamille Rubio
Camille Rubio
JCJavier del Campo
Javier del Campo
Electrochromic materials can be used in self-powered electrochemical sensors to display quantitative information without the need for silicon-based electronics or external instrumentation.

1 January 2007 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
Bruno PolletBruno Pollet
Bruno Pollet
JHJean-Yves Hihn
Jean-Yves Hihn
MDMarie Laure Doche
Marie Laure Doche
JLJ. P. Lorimer
J. P. Lorimer
AMA. Mandroyan
A. Mandroyan
TMT. J. Mason
T. J. Mason
The effect of changing the distance of an ultrasonic horn tip from a stationary platinum disk electrode on limiting current density at various electroanalyte concentrations, ultrasonic frequencies (20 and <mml:math display="inline"><mml:mrow><mml:mn>40</mml:mn><mml:mspace width="0.3em"></mml:mspace><mml:mi>kHz</mml:mi></mml:mrow></mml:math>40kHz ), and ultrasonic intensities was studied in an attempt to find the optimum position required for maximum sonoelectrochemical effect in “face-on” mode. Our findings were compared to mathematical models available in the literature, for the mass transport of electroactive species to the electrode under hydrodynamic flow conditions normal to the ultrasonic horn. A good fit with experimental results was found and confirmed the dependence of limiting current to operating parameters such as ultrasonic power, electrode-to-horn distances and electroactive species diffusion coefficient, and also highlighting the importance of ultrasonic frequency. From mass balance equations, it was then possible to develop an approach by analogy to an electrode subjected to pure hydrodynamic flow. A Levich-like equation relating the limiting current density, the square root of ultrasonic intensity, and the inverse square root of the electrode-horn distance was generated for ultrasonic frequencies of 20 and <mml:math display="inline"><mml:mrow><mml:mn>40</mml:mn><mml:mspace width="0.3em"></mml:mspace><mml:mi>kHz</mml:mi></mml:mrow></mml:math>40kHz , allowing the generation of an “equivalent” flow velocity under sonication, an important and useful parameter in chemical engineering.

1 December 2016 in Surface and Coatings Technology
Verified
Journal Article
Closed access
CRC. Rotty
C. Rotty
AMA. Mandroyan
A. Mandroyan
MDMarie Laure Doche
Marie Laure Doche
JHJean-Yves Hihn
Jean-Yves Hihn

21 May 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Stelian LupuStelian Lupu
Stelian Lupu
CECILIA LETECECILIA LETE
CECILIA LETE
Paul Cătălin BalaurePaul Cătălin Balaure
Paul Cătălin Balaure
DCDan Ion Caval
Dan Ion Caval
CMConstantin Mihailciuc
Constantin Mihailciuc
JCJavier del Campo
Javier del Campo
Bio-composite coatings consisting of poly(3,4-ethylenedioxythiophene) (PEDOT) and tyrosinase (Ty) were successfully electrodeposited on conventional size gold (Au) disk electrodes and microelectrode arrays using sinusoidal voltages. Electrochemical polymerization of the corresponding monomer was carried out in the presence of various Ty amounts in aqueous buffered solutions. The bio-composite coatings prepared using sinusoidal voltages and potentiostatic electrodeposition methods were compared in terms of morphology, electrochemical properties, and biocatalytic activity towards various analytes. The amperometric biosensors were tested in dopamine (DA) and catechol (CT) electroanalysis in aqueous buffered solutions. The analytical performance of the developed biosensors was investigated in terms of linear response range, detection limit, sensitivity, and repeatability. A semi-quantitative multi-analyte procedure for simultaneous determination of DA and CT was developed. The amperometric biosensor prepared using sinusoidal voltages showed much better analytical performance. The Au disk biosensor obtained by 50 mV alternating voltage amplitude displayed a linear response for DA concentrations ranging from 10 to 300 μM, with a detection limit of 4.18 μM.

1 July 2011 in Ultrasonics Sonochemistry
Verified
Journal Article
Closed access
JHJean-Yves Hihn
Jean-Yves Hihn
MDMarie Laure Doche
Marie Laure Doche
AMA. Mandroyan
A. Mandroyan
LHL. Hallez
L. Hallez
Bruno PolletBruno Pollet
Bruno Pollet

1 November 2014 in Ultrasonics Sonochemistry
Verified
Journal Article
Closed access
AMAudrey Mandroyan
Audrey Mandroyan
MMMahmoud Mourad-Mahmoud
Mahmoud Mourad-Mahmoud
MDMarie Laure Doche
Marie Laure Doche
JHJean-Yves Hihn
Jean-Yves Hihn