Wolfgang Kunert

Mr. Wolfgang Kunert


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2011 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
PSPirmin Storz
Pirmin Storz
GBGerhard F. Buess
Gerhard F. Buess
WKWolfgang Kunert
Wolfgang Kunert
AKAndreas Kirschniak
Andreas Kirschniak

18 July 2012 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
WKWolfgang Kunert
Wolfgang Kunert
PSPirmin Storz
Pirmin Storz
AKAndreas Kirschniak
Andreas Kirschniak

8 July 2020 in Surgical Endoscopy
Verified
Journal Article
Open access
PDF file
WKWolfgang Kunert
Wolfgang Kunert
PSPirmin Storz
Pirmin Storz
NDNicolaus Dietz
Nicolaus Dietz
SASteffen Axt
Steffen Axt
CFClaudius Falch
Claudius Falch
PWPeter Wilhelm
Peter Wilhelm
Background: The effectiveness of practical surgical training is characterised by an inherent learning curve. Decisive are individual initial starting capabilities, learning speed, ideal learning plateaus, and resulting learning potentials. The quantification of learning curves requires reproducible tasks with varied levels of difficulty. The hypothesis of this study is that the use of three-dimensional (3D) vision is more advantageous than two-dimensional vision (2D) for the learning curve in laparoscopic training. Methods: Forty laparoscopy novices were recruited and randomised to a 2D Group and a 3D Group. A laparoscopy box trainer with two standardised tasks was used for training of surgical tasks. Task 1 was a positioning task, while Task 2 called for laparoscopic knotting as a more complex process. Each task was repeated at least ten times. Performance time and the number of predefined errors were recorded. 2D performance after 3D training was assessed in an additional final 2D cycle undertaken by the 3D Group. Results: The calculated learning plateaus of both performance times and errors were lower for 3D. Independent of the vision mode the learning curves were smoother (exponential decay) and efficiency was learned faster than precision. The learning potentials varied widely depending on the corresponding initial values and learning plateaus. The final 2D performance time of the 3D-trained group was not significantly better than that of the 2D Group. The final 2D error numbers were similar for all groups. Conclusions: Stereoscopic vision can speed up laparoscopic training. The 3D learning curves resulted in better precision and efficiency. The 3D-trained group did not show inferior performance in the final 2D cycle. Consequently, we encourage the training of surgical competences like suturing and knotting under 3D vision, even if it is not available in clinical routine.

22 July 2020 in Surgical Endoscopy
Verified
Journal Article
Open access
PDF file
JMJohanna Miller
Johanna Miller
MBManuel Braun
Manuel Braun
JBJohannes Bilz
Johannes Bilz
SMSebastian Matich
Sebastian Matich
CNCarsten Neupert
Carsten Neupert
AKAndreas Kirschniak
Andreas Kirschniak
Background: Most currently used surgical robots have no force feedback; the next generation displays forces visually. A novel single-port robotic surgical system called FLEXMIN has been developed. Through an outer diameter of 38 mm, two instruments are teleoperated from a surgeon’s control console including true haptic force feedback. One additional channel incorporates a telescope, another is free for special instrument functions.Methods: This randomized cross-over study analyzed the effect of haptic feedback on the application of intracorporeal forces. In a standardized experiment setup, the subjects had to draw circles with the surgical robot as gently as possible. The applied forces, the required time spans, and predefined error rates were measured.Results: Without haptic feedback, the maximum forces (median/IQR) were 6.43 N/2.96 N. With haptic feedback, the maximum forces were lower (3.57 N/1.94 N,p < 0.001). Also, the arithmetic means of the force progression (p < 0.001) and their standard deviations (p < 0.001) were lower. Not significant were the shorter durations and lower error rates. No sequence effect of force or duration was detected. No characteristic learning or fatigue curve was observed.Conclusions: In the experiment setup, the true haptic force feedback can reduce the applied intracorporeal robotic force to one-half when considering the aspects maximum, means, and standard deviation. Other test tasks are needed to validate the influence of force feedback on surgical efficiency and safety.

1 March 2021 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PBPatrick Beyersdorffer
Patrick Beyersdorffer
WKWolfgang Kunert
Wolfgang Kunert
KJKai Jansen
Kai Jansen
JMJohanna Miller
Johanna Miller
PWPeter Wilhelm
Peter Wilhelm
JRJens Rolinger
Jens Rolinger
Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train the CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labeled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.

20 July 2018 in Surgical Innovation
Verified
Journal Article
Closed access
WKWolfgang Kunert
Wolfgang Kunert
TAThomas Auer
Thomas Auer
PSPirmin Storz
Pirmin Storz
MBManuel Braun
Manuel Braun
AKAndreas Kirschniak
Andreas Kirschniak
CFClaudius Falch
Claudius Falch
Background. To regain 2-eyed vision in laparoscopy, dual-channeled optics have been introduced. With this optics design, the distance between the 2 front lenses defines how much stereoscopic effect is seen. This study quantifies the impact of an enhanced and a reduced stereo effect on surgical task efficiency. Methods. A prospective single-blinded study was performed with 20 laparoscopic novices in an inanimate experimental setting. A standard bichannelled stereo system was used to perform a suturing and knotting task. The working distance and the task size were scaled to vary the stereo effect and, thereby, simulate hypothetic stereo optics with enhanced and reduced optical bases. The task performances were timed, and the number of trials for stitching out was counted. The participants finally filled out a questionnaire to collect subjective impressions. Results. The increase of the stereo effect by 50% caused no objective improvement in laparoscopic knotting compared with typical 3D (control group with stereo basis of 4.5 mm). But ergonomic disadvantages (headache) were subjectively reported in 1 of 20 cases in the questionnaire. The reduction of the stereo effect by one-third led to a significantly longer average execution time. There was no significant dependence found between stereo effect and number of stich-out trials, stitching precision, or knotting quality. Conclusions. Considering laparoscopy, it does not seem advisable to enhance the stereo effect because of ergonomic problems. Otherwise, a miniaturization of the 3D scope (5 mm version) is problematic because its benefit mostly shrinks with the reduced stereo effect.