Peter Wilhelm

Peter Wilhelm

Auto-generated profile, based on publicly available information

Peter Wilhelm

Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Holstenstr, Hamburg, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PBPatrick Beyersdorffer
Patrick Beyersdorffer
WKWolfgang Kunert
Wolfgang Kunert
KJKai Jansen
Kai Jansen
JMJohanna Miller
Johanna Miller
PWPeter Wilhelm
Peter Wilhelm
JRJens Rolinger
Jens Rolinger
Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train the CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labeled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.

28 November 2019 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Closed access
LDLorenz Domhan
Lorenz Domhan
JJJonas Johannink
Jonas Johannink
JMJohanna Miller
Johanna Miller
VSVolker Steger
Volker Steger
ALAlbert Linder
Albert Linder
PWPeter Wilhelm
Peter Wilhelm
OBJECTIVES: Video-assisted thoracic surgery (VATS) is a complex technique requiring dedicated surgical training. Platforms for such training are scarce and often rely on the use of live animals, which raises ethical concerns. The objective of this study was to develop a box trainer that is dedicated for VATS training and able to reproduce bleeding scenarios. METHODS: The developed Tuebingen Thorax Trainer comprises 5 components that are mounted on a human anatomy-like thoracic cavity containing a porcine organ complex. Any standard thoracoscopic instrument can be used. The organ complex is attached to a perfusion module. We assessed the applicability of the system in four 1-day VATS training courses at the Tuebingen Surgical Training Center. Assessment was performed using a questionnaire handed out to all participants. RESULTS: Forty participants have been trained with the Tuebingen Thorax Trainer at our institution since November 2016. Thirty-five (87.5%) participants stated that the Tuebingen Thorax Trainer is an adequate model for VATS training. The ex vivo organ complex was reported to be realistic with regards to the level of detail and scale (76%). A large proportion of participants (27.5%) were experienced with VATS and reported having performed >50 procedures before taking the training course. CONCLUSIONS: This new training device allows realistic training for VATS procedures. ‘Stagnant hydrostatic perfusion’ permits simulation of reproducible bleeding scenarios. The device is low in production costs and offers a strong resemblance to the clinical scenario. It reduces the use of animal models and contributes to the efforts in making surgical skills training for VATS more accessible.

1 November 2020 in Annals of Anatomy - Anatomischer Anzeiger
Verified
Journal Article
Closed access
PWP. Wilhelm
P. Wilhelm
DSD. Stierle
D. Stierle
JRJ. Rolinger
J. Rolinger
CFC. Falch
C. Falch
UDU. Drews
U. Drews
AKA. Kirschniak
A. Kirschniak

28 March 2022 in Joint Diseases and Related Surgery
Verified
Journal Article
Open access
PDF file
VMVincenzo de Matteo
Vincenzo de Matteo
FFFelipe Forero
Felipe Forero
SBSophia-Marlene Busch
Sophia-Marlene Busch
PLPhilip Linke
Philip Linke
PWPeter Wilhelm
Peter Wilhelm
MCMustafa Citak
Mustafa Citak
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.

25 January 2022 in 4open
Verified
Journal Article
Open access
PDF file
JRJens Rolinger
Jens Rolinger
NMNils Model
Nils Model
KJKai Jansen
Kai Jansen
MKMadeleine Knöll
Madeleine Knöll
PBPatrick Beyersdorffer
Patrick Beyersdorffer
PWPeter Wilhelm
Peter Wilhelm
Uncontrolled movement of instruments in laparoscopic surgery can lead to inadvertent tissue damage, particularly when the dissecting or electrosurgical instrument is located outside the field of view of the laparoscopic camera. The incidence and relevance of such events are currently unknown. The present work aims to identify and quantify potentially dangerous situations using the example of laparoscopic cholecystectomy (LC). Twenty-four final year medical students were prompted to each perform four consecutive LC attempts on a well-established box trainer in a surgical training environment following a standardized protocol in a porcine model. The following situation was defined as a critical event (CE): the dissecting instrument was inadvertently located outside the laparoscopic camera’s field of view. Simultaneous activation of the electrosurgical unit was defined as a highly critical event (hCE). Primary endpoint was the incidence of CEs. While performing 96 LCs, 2895 CEs were observed. Of these, 1059 (36.6%) were hCEs. The median number of CEs per LC was 20.5 (range: 1–125; IQR: 33) and the median number of hCEs per LC was 8.0 (range: 0–54, IQR: 10). Mean total operation time was 34.7 min (range: 15.6–62.5 min, IQR: 14.3 min). Our study demonstrates the significance of CEs as a potential risk factor for collateral damage during LC. Further studies are needed to investigate the occurrence of CE in clinical practice, not just for laparoscopic cholecystectomy but also for other procedures. Systematic training of future surgeons as well as technical solutions address this safety issue.

25 September 2019 in Innovative Surgical Sciences
Verified
Journal Article
Open access
PDF file
JMJakob Mann
Jakob Mann
JRJens Rolinger
Jens Rolinger
SASteffen Axt
Steffen Axt
AKAndreas Kirschniak
Andreas Kirschniak
PWPeter Wilhelm
Peter Wilhelm
Background: Transanal total mesorectal excision (taTME) has been subject to extensive research and increasing clinical application. It allows further reduction of trauma by accessing via a natural orifice. Manifold platforms and instruments have been introduced and heterogeneity in surgical techniques exists. Because of the technique’s complexity there is a persistent need for dedicated training devices and concepts.Materials and methods: The key steps of taTME were analyzed and a box trainer with three modules resembling these steps was designed and manufactured. Twenty-one surgically inexperienced medical students performed five repetitions of the three tasks with the new box trainer. Time and error count were analyzed for assessment of a learning curve.Results: A significant reduction of processing time could be demonstrated for tasks 1–3 (p < 0.001; p < 0.001; p = 0.001). The effect size was high for comparison of repetition 1 and 5 and decreased over the course (task 1: r = 0.88 vs. r = 0.21; task 2: r = 0.86 vs. r = 0.23; task 3: r = 0.74 vs. r = 0.44). Also, a significant reduction of errors was demonstrated for tasks 1 and 2. The decrease of effect size was analogously demonstrated.Conclusions: The trainer might help to reduce the use of animal models for testing of platforms and instruments as well as gaining first-hand experience in transanal rectal resection.