Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train the CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labeled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.
The purpose of this study is to investigate self-reported financial difficulties (FDs) in patients with colorectal cancer (CRC) and to develop easy-to-implement models to predict FDs 1 year after initiation of CRC treatment. In the prospective EDIUM cohort, CRC patients are asked to complete the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire Core 30 (QLQ-C30) and QLQ-CR29 before (T0) and 1 year after initiation of treatment (T1). These patient-reported outcomes are combined with sociodemographic and clinical data. The QLQ-C30 'FD' item is firstly analysed descriptively, together with covariates. Logistic lasso regression was carried out to develop a predictive model (full model) of FDs at T1, and its predictive capacity was assessed. This predictive model was then simplified using easy-to-collect predictors which showed importance in the full model. Of 9124 CRC patients enrolled between October 2018 and May 2023, 6061 completed follow-up questionnaires (T1). Of those initially without FDs (n = 4989), 25% (1248 patients) reported new FDs at T1. These patients were younger [median age 66 versus 72 years; odds ratio (OR) 2.81 (95% confidence interval [CI] 2.46-3.22)] and had a higher proportion of lower educational attainment [74% versus 69%; OR 1.32 (95% CI 1.14-1.54)]. Clinically, FDs were more frequently reported by patients with higher International Union Against Cancer (UICC) stages [48% in stages III/IV versus 32.5% in stages I/II; OR 1.98 (95% CI 1.74-2.26)] and rectal cancer [37% versus 28%; OR 1.52 (95% CI 1.32-1.73)]. The full model [based on a test and training dataset of n = 5910 patients, including 14 predictors, area under the curve (AUC) 0.75] was reduced to two simplified models with only the predictors age, sex (model 1, AUC 0.72)/localisation of tumour (model 2), and FDs at T0 (AUC = 0.74). On this basis, two risk assessment tables were developed. A significant proportion of CRC patients report FDs 1 year after treatment initiation, particularly among socioeconomically disadvantaged groups. Together with the predictive models and two ready-to-use risk assessment tables, these findings can be utilised by clinicians and psychosocial counselling services to provide tailored support options.
1 November 2020 in Annals of Anatomy - Anatomischer Anzeiger
Uncontrolled movement of instruments in laparoscopic surgery can lead to inadvertent tissue damage, particularly when the dissecting or electrosurgical instrument is located outside the field of view of the laparoscopic camera. The incidence and relevance of such events are currently unknown. The present work aims to identify and quantify potentially dangerous situations using the example of laparoscopic cholecystectomy (LC). Twenty-four final year medical students were prompted to each perform four consecutive LC attempts on a well-established box trainer in a surgical training environment following a standardized protocol in a porcine model. The following situation was defined as a critical event (CE): the dissecting instrument was inadvertently located outside the laparoscopic camera’s field of view. Simultaneous activation of the electrosurgical unit was defined as a highly critical event (hCE). Primary endpoint was the incidence of CEs. While performing 96 LCs, 2895 CEs were observed. Of these, 1059 (36.6%) were hCEs. The median number of CEs per LC was 20.5 (range: 1–125; IQR: 33) and the median number of hCEs per LC was 8.0 (range: 0–54, IQR: 10). Mean total operation time was 34.7 min (range: 15.6–62.5 min, IQR: 14.3 min). Our study demonstrates the significance of CEs as a potential risk factor for collateral damage during LC. Further studies are needed to investigate the occurrence of CE in clinical practice, not just for laparoscopic cholecystectomy but also for other procedures. Systematic training of future surgeons as well as technical solutions address this safety issue.