Purpose: Although theoretical modelling is widely used to study different aspects of radiofrequency ablation (RFA), its utility is directly related to its realism. An important factor in this realism is the use of mathematical functions to model the temperature dependence of thermal (k) and electrical (σ) conductivities of tissue. Our aim was to review the piecewise mathematical functions most commonly used for modelling the temperature dependence of k and σ in RFA computational modelling. Materials and methods: We built a hepatic RFA theoretical model of a cooled electrode and compared lesion dimensions and impedance evolution with combinations of mathematical functions proposed in previous studies. We employed the thermal damage contour D63 to compute the lesion dimension contour, which corresponds to Ω = 1, Ω being local thermal damage assessed by the Arrhenius damage model. Results: The results were very similar in all cases in terms of impedance evolution and lesion size after 6 min of ablation. Although the relative differences between cases in terms of time to first roll-off (abrupt increase in impedance) were as much as 12%, the maximum relative differences in terms of the short lesion (transverse) diameter were below 3.5%. Conclusions: The findings suggest that the different methods of modelling temperature dependence of k and σ reported in the literature do not significantly affect the computed lesion diameter.
24 July 2016 in International Journal of Hyperthermia
Purpose: To develop computer models to mimic the impedance-controlled pulsing protocol implemented in radiofrequency (RF) generators used for clinical practice of radiofrequency ablation (RFA), and to assess the appropriateness of the models by comparing the computer results with those obtained in previous experimental studies. Methods: A 12-min RFA was modelled using a cooled electrode (17G, 3 cm tip) inserted in hepatic tissue. The short (transverse) diameter of the coagulation zone was assessed under in vivo (with blood perfusion (BP) and considering clamping) and ex vivo (at 21 °C) conditions. The computer results obtained by programming voltage pulses were compared with current pulses. Results: The differences between voltage and current pulses were noticeable: using current instead of voltage allows larger coagulation zones to be created, due to the higher energy applied by current pulses. If voltage pulses are employed the model can accurately predict the number of roll-offs, although the waveform of the applied power is clearly not realistic. If current voltages are employed, the applied power waveform matches well with those reported experimentally, but there are significantly fewer roll-offs. Our computer results were overall into the ranges of experimental ones. Conclusions: The proposed models reproduce reasonably well the electrical-thermal performance and coagulation zone size obtained during an impedance-controlled pulsing protocol.
The concept of function is a threshold concept in mathematics since it is essential for a deep understanding of the subject and is often problematic for students. Despite the importance of this concept, numerous studies have found that students have several difficulties and misconceptions about it. This work aims to assess, classify and synthesize the existing information about the learning difficulties and misconceptions related to the concept of function. In this sense, the main achievement of the work is the synthesis and classification by topics of the information gathered from the literature.
1 January 2021 in International Journal of Hyperthermia
To study the differences between continuous and short-pulse mode microwave ablation (MWA).We built a computational model for MWA including a 200 mm long and 14 G antenna from Amica-Gen and solved a...
20 February 2009 in Mathematical Medicine and Biology: A Journal of the IMA
In this paper, we solve in an analytical way the thermal-optic coupled problem associated with a 1D model of non-perfused homogeneous biological tissue irradiated by a laser beam. We consider a laser pulse duration of 200 μs and study the temperatures of areas very close to the point of laser beam application. We consider that these values of the temporal and spatial variables mean that the problem has to be solved by means of the hyperbolic heat conduction model instead of the classic or parabolic model. We therefore obtain the solution using both models and apply the temperature profiles obtained to a specific biological tissue for comparison. Finally, we theoretically study the effect of the thermal relaxation time on the temperature profiles in the tissue for both heating and cooling phases (i.e. during and after laser application).
1 January 2015 in Discrete and Continuous Dynamical Systems
The Hyperbolic Heat Transfer Equation describes heat processes in which extremely short periods of time or extreme temperature gradients are involved. It is already known that there are solutions of this equation which exhibit a chaotic behaviour, in the sense of Devaney, on certain spaces of analytic functions with certain growth control. We show that this chaotic behaviour still appears when we add a source term to this equation, i.e. in the Hyperbolic Bioheat Equation. These results can also be applied for the Wave Equation and for a higher order version of the Hyperbolic Bioheat Equation.