Zia Saadatnia

Dr. Zia Saadatnia

Department of Mechanical and Industrial Engineering, University of Toronto, 27 King's College Cir, Toronto, ON M5S, Canada

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2017 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
Zia SaadatniaZia Saadatnia
Zia Saadatnia
EAEhsan Asadi
Ehsan Asadi
HAHassan Askari
Hassan Askari
JZJean Zu
Jean Zu
EEEbrahim Esmailzadeh
Ebrahim Esmailzadeh

28 February 2018 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
Zia SaadatniaZia Saadatnia
Zia Saadatnia
EAEhsan Asadi
Ehsan Asadi
HAHassan Askari
Hassan Askari
EEEbrahim Esmailzadeh
Ebrahim Esmailzadeh
HNHani E Naguib
Hani E Naguib

1 October 2024 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
OTOmid Aghababaei Tafreshi
Omid Aghababaei Tafreshi
Zia SaadatniaZia Saadatnia
Zia Saadatnia
SGShahriar Ghaffari-Mosanenzadeh
Shahriar Ghaffari-Mosanenzadeh
MRMohammad Mahdi Rastegardoost
Mohammad Mahdi Rastegardoost
CZChangxing Zhang
Changxing Zhang
HNHani E Naguib
Hani E Naguib

1 May 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TCTianhao Chen
Tianhao Chen
Zia SaadatniaZia Saadatnia
Zia Saadatnia
JKJongwoo Kim
Jongwoo Kim
TLThomas Looi
Thomas Looi
JDJames Drake
James Drake
HNHani E Naguib
Hani E Naguib
Remote-controlled minimally invasive neuroendoscopic robotic surgical tools can be miniaturized to a size of less than 2 mm while maintaining their dexterity and force required to perform operations in brain without an open-skull surgery. However, these platforms lack haptic information to be received by the surgeons, leading to loss of control over tissue and causing unexpected slippage and trauma. This study presents the design of small and highly sensitive material-based sensor being integrated to the tool shaft, known as the concentric tube manipulators, to achieve static and quasi-static force sensing and feedback. Through a 9-element design and contact mechanics modelling, the sensor system can generate real-time polar visual pressure profile displays. Optimizations were performed on the sub-components of the sensor design including microstructures and electrodes to improve detection threshold with reduced hysteresis. The finalized design can sense a force from as low as 14.8 ± 1.22 mN to 1 N with excellent proportionality between the acquired signal and force applied while retaining its flexibility and sterilizability. The sensor will also enhance more intuitive force feedback for surgeons to use the dexterous neurosurgical tool, ensuring safety and quality of operations for minimally invasive surgeries for brain tumor and epilepsy practice.

8 September 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Zia SaadatniaZia Saadatnia
Zia Saadatnia
SGShahriar GhaffariMosanenzadeh
Shahriar GhaffariMosanenzadeh
MCMelissa Marquez Chin
Melissa Marquez Chin
HNHani E Naguib
Hani E Naguib
MPMilos R. Popovic
Milos R. Popovic
This study presents a novel type of wet electrode material for electrophysiological monitoring based on a conductive aerogel film. The electrode material incorporates cellulose nanocrystal and fiber as a biocompatible polymer and multi-walled carbon nanotube as a conductive filler. The fabricated electrode is fully characterized to explore the chemical, mechanical, electrical, and water absorption properties. The wet aerogel film presents suitable mechanical flexibility owing to the use of fiber enabling it to be conformal to curved surfaces like human body. The water absorption percentage of the fabricated aerogel film is extremely high (~500%) due to the porosity of the film and hydrophilicity of the base polymer allowing it for effective wet electrode applications. The film is air dryable with a fast (~10 min) and facile wetting process granting the electrode application for long-term, multiple use, and remote monitoring of patients. The electrical impedance range of the fabricated aerogel electrodes is relatively low (20 /cm2-370 /cm2) which is within the range of use for various electrophysiological monitoring purposes such as electrocardiography (ECG) and electroencephalography (EEG). Overall, the presented study introduces a novel wet electrode based on porous and electrically conductive aerogel film to be used for various biomedical applications.