Thomas Looi

Dr. Thomas Looi


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2011 in Child's Nervous System
Verified
Journal Article
Closed access
PDF file
NSNikoo R. Saber
Nikoo R. Saber
JPJohn Phillips
John Phillips
TLThomas Looi
Thomas Looi
ZUZoha Usmani
Zoha Usmani
JBJonathan Burge
Jonathan Burge
PKPeter C. W. Kim
Peter C. W. Kim

21 January 2019 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CFCameron Forbrigger
Cameron Forbrigger
ALAndrew Lim
Andrew Lim
OOOnaizah Onaizah
Onaizah Onaizah
SSSajad Salmanipour
Sajad Salmanipour
TLThomas Looi
Thomas Looi
EDEric D. Diller
Eric D. Diller
A novel end-effector for surgical applications is presented that uses magnetic actuation in lieu of a more traditional cable-driven system. The gripper and wrist device consists of several magnets connected with compliant Nitinol joints that allow two rotational degrees of freedom and one gripping degree of freedom. As an end effector for an existing surgical robot arm, this device could augment existing minimally invasive surgical robots by allowing high distal dexterity in surgical sites with narrow and restricted access. A static deflection model of the device is used to design an open loop controller. The current prototype is capable of exerting pushing/pulling forces of 9 mN and gripping forces of 6 mN when magnetic flux densities of 20 mT are applied by a laboratory-scale electromagnetic coil system. These forces could be greatly amplified in a clinical-scale system to make brain tissue resection feasible. Under open loop control, the wrist of the device can maneuver from +π/4 rad to -π/4 rad in less than one second with a maximum error of 0.12 rad.

1 May 2013
Verified
Conference Paper
Closed access
SISantosh Iyer
Santosh Iyer
TLThomas Looi
Thomas Looi
JDJames Drake
James Drake
In this paper, a novel approach for automated suturing is introduced and experimental results are presented. Unlike other similar works, the proposed approach adopts a single arm to implement a suturing task with a standard laparoscopic needle holder and curved suture needle. 3D information is obtained from a clinical (single camera) endoscope through an elliptical/circular pose measurement algorithm, which dynamically tracks the suture needle and surface markers. This drives robotic needle steering through a set of surgeon-defined entry/exit points on a tissue pad phantom. Implementation results indicate good depth resolution (1.5mm) and task repeatability (85%) for a variety of consistency, lighting, and location variation scenarios.

1 May 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TCTianhao Chen
Tianhao Chen
Zia SaadatniaZia Saadatnia
Zia Saadatnia
JKJongwoo Kim
Jongwoo Kim
TLThomas Looi
Thomas Looi
JDJames Drake
James Drake
HNHani E Naguib
Hani E Naguib
Remote-controlled minimally invasive neuroendoscopic robotic surgical tools can be miniaturized to a size of less than 2 mm while maintaining their dexterity and force required to perform operations in brain without an open-skull surgery. However, these platforms lack haptic information to be received by the surgeons, leading to loss of control over tissue and causing unexpected slippage and trauma. This study presents the design of small and highly sensitive material-based sensor being integrated to the tool shaft, known as the concentric tube manipulators, to achieve static and quasi-static force sensing and feedback. Through a 9-element design and contact mechanics modelling, the sensor system can generate real-time polar visual pressure profile displays. Optimizations were performed on the sub-components of the sensor design including microstructures and electrodes to improve detection threshold with reduced hysteresis. The finalized design can sense a force from as low as 14.8 ± 1.22 mN to 1 N with excellent proportionality between the acquired signal and force applied while retaining its flexibility and sterilizability. The sensor will also enhance more intuitive force feedback for surgeons to use the dexterous neurosurgical tool, ensuring safety and quality of operations for minimally invasive surgeries for brain tumor and epilepsy practice.

8 July 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ALAndrew Lim
Andrew Lim
ASAdam Schonewille
Adam Schonewille
CFCameron Forbrigger
Cameron Forbrigger
TLThomas Looi
Thomas Looi
JDJames Drake
James Drake
EDEric Diller
Eric Diller
Robot-assisted minimally invasive surgical (MIS) techniques offer improved instrument precision and dexterity, reduced patient trauma and risk, and promise to lessen the skill gap among surgeons. These approaches are common in general surgery, urology, and gynecology. However, MIS techniques remain largely absent for surgical applications with narrow, confined workspaces, such as neuroendoscopy. The limitation stems from a lack of small yet dexterous robotic tools. In this work, we present the first instance of a surgical robot with a direct magnetically-driven end effector capable of being deployed through a standard neuroendoscopic working channel (3.2 mm outer diameter) and operate at the neuroventricular scale. We propose a physical model for the gripping performance of three unique end-effector magnetization profiles and mechanical designs. Blocking force rates per external magnetic flux density were 0.309 N/T, 0.880 N/T, and 0.351 N/T for the three designs which matched the physical models prediction within 14.9% error. The rate of gripper closure per external magnetic flux density had a mean percent error of 11.2% compared to the model. The robots performance was qualitatively evaluated during a pineal region tumor resection on a tumor analogue in a silicone brain phantom. These results suggest that wireless magnetic actuation may be feasible for dexterously manipulating tissue during minimally invasive neurosurgical procedures.

4 June 2013 in Journal of Therapeutic Ultrasound
Verified
Journal Article
Open access
PDF file
BZBenjamin Zaporzan
Benjamin Zaporzan
AWAdam C Waspe
Adam C Waspe
TLThomas Looi
Thomas Looi
CMCharles Mougenot
Charles Mougenot
APAri Partanen
Ari Partanen
SPSamuel Pichardo
Samuel Pichardo
Background: The availability of open and versatile software tools is a key feature to facilitate pre-clinical research for magnetic resonance imaging (MRI) and magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) and expedite clinical translation of diagnostic and therapeutic medical applications. In the present study, two customizable software tools that were developed at the Thunder Bay Regional Research Institute are presented for use with both MRI and MR-HIFU. Both tools operate in a MATLAB®; environment. The first tool is named MatMRI and enables real-time, dynamic acquisition of MR images with a Philips MRI scanner. The second tool is named MatHIFU and enables the execution and dynamic modification of user-defined treatment protocols with the Philips Sonalleve MR-HIFU therapy system to perform ultrasound exposures in MR-HIFU therapy applications. Methods: MatMRI requires four basic steps: initiate communication, subscribe to MRI data, query for new images, and unsubscribe. MatMRI can also pause/resume the imaging and perform real-time updates of the location and orientation of images. MatHIFU requires four basic steps: initiate communication, prepare treatment protocol, and execute treatment protocol. MatHIFU can monitor the state of execution and, if required, modify the protocol in real time. Results: Four applications were developed to showcase the capabilities of MatMRI and MatHIFU to perform pre-clinical research. Firstly, MatMRI was integrated with an existing small animal MR-HIFU system (FUS Instruments, Toronto, Ontario, Canada) to provide real-time temperature measurements. Secondly, MatMRI was used to perform T2-based MR thermometry in the bone marrow. Thirdly, MatHIFU was used to automate acoustic hydrophone measurements on a per-element basis of the 256-element transducer of the Sonalleve system. Finally, MatMRI and MatHIFU were combined to produce and image a heating pattern that recreates the word ‘HIFU’ in a tissue-mimicking heating phantom. Conclusions: MatMRI and MatHIFU leverage existing MRI and MR-HIFU clinical platforms to facilitate pre-clinical research. MatMRI substantially simplifies the real-time acquisition and processing of MR data. MatHIFU facilitates the testing and characterization of new therapy applications using the Philips Sonalleve clinical MR-HIFU system. Under coordination with Philips Healthcare, both MatMRI and MatHIFU are intended to be freely available as open-source software packages to other research groups.