Omar Daud

Dr. Omar Daud

CEDENNA - Universidad de Santiago de Chile

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2017 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
CTClaudio Tapia
Claudio Tapia
ODOmar Daud
Omar Daud
JRJavier Ruiz-del-Solar
Javier Ruiz-del-Solar

24 January 2021 in Minerals
Verified
Journal Article
Open access
PDF file
ODOmar Daud
Omar Daud
MCMauricio Correa
Mauricio Correa
HEHumberto Estay
Humberto Estay
JRJavier Ruiz-del-Solar
Javier Ruiz-del-Solar
This manuscript describes a method that is based on the implementation and setup of a mechatronic system that can recognize and detect, through thermal analysis, the zones where heap leaching piles may become locally saturated. Such a condition could trigger the potential of liquefaction, generating local or general collapse in the pile. In order to reduce this potential danger, and therefore achieve full stability in the pile, the irrigation system must be properly controlled; for instance, in potentially saturated zones, the irrigation flow can be reduced or eliminated until the saturation has disappeared. The mechatronic system consists of a hexacopter, equipped with a thermal infrared camera mounted on its structure and pointing down to the ground, which is used to obtain the temperature information of the heat transfer between the heap pile and the environment. Such information is very useful, as the level of saturated zones can then be traced. The communication between the operator of the irrigation system and the mechatronic system is based on a radio-frequency link, in which geo-referenced images are transmitted.

1 October 2016 in Sensors
Verified
Journal Article
Open access
PDF file
FOFabio Oscari
Fabio Oscari
RORoberto Oboe
Roberto Oboe
ODOmar Daud
Omar Daud
Masiero StefanoMasiero Stefano
Masiero Stefano
Giulio RosatiGiulio Rosati
Giulio Rosati
The use of haptic devices in the rehabilitation of impaired limbs has become rather popular, given the proven effectiveness in promoting recovery. In a standard framework, such devices are used in rehabilitation centers, where patients interact with virtual tasks, presented on a screen. To track their sessions, kinematic/dynamic parameters or performance scores are recorded. However, as Internet access is now available at almost every home and in order to reduce the hospitalization time of the patient, the idea of doing rehabilitation at home is gaining wide consent. Medical care programs can be synchronized with the home rehabilitation device; patient data can be sent to the central server that could redirect to the therapist laptop (tele-healthcare). The controversial issue is that the recorded data do not actually represent the clinical conditions of the patients according to the medical assessment scales, forcing them to frequently undergo clinical tests at the hospital. To respond to this demand, we propose the use of a bilateral master/slave haptic system that could allow the clinician, who interacts with the master, to assess remotely and in real time the clinical conditions of the patient that uses the home rehabilitation device as the slave. In this paper, we describe a proof of concept to highlight the main issues of such an application, limited to one degree of freedom, and to the measure of the stiffness and range of motion of the hand.

13 September 2016 in Robotica
Verified
Journal Article
Closed access
PDF file
ODOmar Daud
Omar Daud
RORoberto Oboe
Roberto Oboe
FOFabio Oscari
Fabio Oscari
Masiero StefanoMasiero Stefano
Masiero Stefano
Giulio RosatiGiulio Rosati
Giulio Rosati
SUMMARY: Haptic devices have proven effective in stimulating proprioceptive sensing in post-stroke patients. In this work, pre-existing devices were used together in a remote environment for the teleassessment of impaired hands. A four-channel bilateral control system in the presence of large and variable time delay is proposed as a proof of concept. Time delay is managed with a novel communication disturbance observer (CDOB). The system also employed a scaling down compensation value (SDCV) for the CDOB. The proposed control system was tested successfully in bilateral haptic interaction, simulating a remote motor and functional evaluation of patients' hands, guaranteeing safe and stable interaction, even in the presence of large network delays.