Fabio Oscari

Dr. Fabio Oscari


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Giulio RosatiGiulio Rosati
Giulio Rosati
FOFabio Oscari
Fabio Oscari
SSSimone Spagnol
Simone Spagnol
Federico  AvanziniFederico Avanzini
Federico Avanzini
Masiero StefanoMasiero Stefano
Masiero Stefano
This paper presents the results of a set of experiments in which we used continuous auditory feedback to augment motor training exercises. This feedback modality is mostly underexploited in current robotic rehabilitation systems, which usually implement only very basic auditory interfaces. Our hypothesis is that properly designed continuous auditory feedback could be used to represent temporal and spatial information that could in turn, improve performance and motor learning.

26 June 2012 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
FOFabio Oscari
Fabio Oscari
RSRiccardo Secoli
Riccardo Secoli
Federico  AvanziniFederico Avanzini
Federico Avanzini
Giulio RosatiGiulio Rosati
Giulio Rosati
DRDavid J. Reinkensmeyer
David J. Reinkensmeyer

4 September 2017 in Assembly Automation
Verified
Journal Article
Closed access
LBLuca Barbazza
Luca Barbazza
Maurizio FaccioMaurizio Faccio
Maurizio Faccio
FOFabio Oscari
Fabio Oscari
Giulio RosatiGiulio Rosati
Giulio Rosati
Purpose: This paper aims at analyzing different possible assembly systems, including innovative potential configurations such as the fully flexible assembly systems (FAS), by defining a novel analytical model that focuses on the concept of agility and its impact on the whole system performance, also evaluating the economic convenience in terms of the unit direct production cost. Design/methodology/approach: The authors propose a comparison model derived by Newton’s second law, introducing a quantitative definition of agility (acceleration), resistance of an assembly system to any change of its operative state (inertia) and unit direct production cost (force). Different types of assembly systems (manual, flexible and fully FAS) are analyzed and compared using the proposed model, investigating agility, system inertia and their impact on the unit direct production cost. Findings: The proposed agility definition and the proposed comparison model have been applied considering different sets of parameters as independent variables, such as the number of components to assemble (product model complexity) and the target throughput of the system. The main findings are a series of convenience areas which either, for a given target unit direct production cost (force), defines the most agile system to adopt or, for a given target agility (acceleration), defines the most economical system to adopt, as function of the independent variables. Originality/value: The novelty of this work is, first, the analytical definition of agility applied to assembly systems and contextualized by means of the definition of the new comparison model. The comparison between different assembly systems on the basis of agility, and by using different sets of independent variables, is a further element of interest. Finally, the resulting convenience areas represent a desirable tool that could be used to optimally choose the most suitable assembly system according to one or more system parameters.

16 June 2016 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
FOFabio Oscari
Fabio Oscari
CFChristian Finetto
Christian Finetto
SKSteve A Kautz
Steve A Kautz
Giulio RosatiGiulio Rosati
Giulio Rosati
Robotic neurorehabilitation aims at promoting the recovery of lost function after neurological injury by leveraging strategies of motor learning. One important aspect of the rehabilitation process is the improvement of muscle coordination patterns, which can be drastically altered after stroke. However, it is not fully understood if and how robotic therapy can address these deficits. The aim of our study was to find how muscle coordination, analyzed from the perspective of motor modules, could change during motor adaptation to a dynamic environment generated by a haptic interface. In our experiment we employed the traditional paradigm of exposure to a viscous force field to subjects that grasped the handle of an actuated joystick during a reaching movement (participants moved directly forward and back by 30 c m). EMG signals of ten muscles of the tested arm were recorded. We extracted motor modules from the pooled EMG data of all subjects and analyzed the muscle coordination patterns. We found that the participants reacted by using a coordination strategy that could be explained by a change in the activation of motor modules used during free motion and by two complementary modules. These complementary modules aggregated changes in muscle coordination, and evolved throughout the experiment eventually maintaining a comparable structure until the late phase of re-adaptation. This result suggests that motor adaptation induced by the interaction with a robotic device can lead to changes in the muscle coordination patterns of the subject.

1 October 2016 in Sensors
Verified
Journal Article
Open access
PDF file
FOFabio Oscari
Fabio Oscari
RORoberto Oboe
Roberto Oboe
ODOmar Daud
Omar Daud
Masiero StefanoMasiero Stefano
Masiero Stefano
Giulio RosatiGiulio Rosati
Giulio Rosati
The use of haptic devices in the rehabilitation of impaired limbs has become rather popular, given the proven effectiveness in promoting recovery. In a standard framework, such devices are used in rehabilitation centers, where patients interact with virtual tasks, presented on a screen. To track their sessions, kinematic/dynamic parameters or performance scores are recorded. However, as Internet access is now available at almost every home and in order to reduce the hospitalization time of the patient, the idea of doing rehabilitation at home is gaining wide consent. Medical care programs can be synchronized with the home rehabilitation device; patient data can be sent to the central server that could redirect to the therapist laptop (tele-healthcare). The controversial issue is that the recorded data do not actually represent the clinical conditions of the patients according to the medical assessment scales, forcing them to frequently undergo clinical tests at the hospital. To respond to this demand, we propose the use of a bilateral master/slave haptic system that could allow the clinician, who interacts with the master, to assess remotely and in real time the clinical conditions of the patient that uses the home rehabilitation device as the slave. In this paper, we describe a proof of concept to highlight the main issues of such an application, limited to one degree of freedom, and to the measure of the stiffness and range of motion of the hand.

1 January 2010
Verified
Conference Paper
Closed access
PDF file
SCStefano Cenci
Stefano Cenci
Giulio RosatiGiulio Rosati
Giulio Rosati
Damiano ZanottoDamiano Zanotto
Damiano Zanotto
FOFabio Oscari
Fabio Oscari
ARAldo Rossi
Aldo Rossi
According to a recent report of ILO (International Labour Organization), more than two million people die or loose the working capability every year because of accidents or work-related diseases. A large portion of these accidents are related to the execution of motion and transportation tasks involving heavy duty machines. The insufficient degree of interaction between the human operator and the machine may be regarded as one of the major causes of this phenomenon. The main goal of the tele-operation system presented in this paper is to both preserving slave (machine) stability, by reducing the inputs of slave actuators when certain unsafe working conditions occur, and improving the level of interaction at master (operator) side. Different control schemes are proposed in the paper, including several combinations of master and slave control strategies. The effectiveness of the algorithms is analyzed by presenting some experimental results, based on the use of a two degrees-of-freedom force feedback input device (with one active actuator and one passive stiff joint) coupled with a simulator of a telescopic handler.