Adnan Zahid

Adnan Zahid


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Umer SaeedUmer Saeed
Umer Saeed
SSSyed Yaseen Shah
Syed Yaseen Shah
AZAdnan Zahid
Adnan Zahid
Jawad AhmadJawad Ahmad
Jawad Ahmad
Muhammad ImranMuhammad Imran
Muhammad Imran
Qammer AbbasiQammer Abbasi
Qammer Abbasi
Contactless or non-invasive technology has a significant impact on healthcare applications such as the prediction of COVID-19 symptoms. Non-invasive methods are essential especially during the COVID-19 pandemic as they minimise the burden on healthcare personnel. One notable symptom of COVID-19 infection is a rapid respiratory rate, which requires constant real-time monitoring of respiratory patterns. In this paper, Software Defined Radio (SDR) based Radio-Frequency sensing technique and supervised machine learning algorithm is employed to provide a platform for detecting and monitoring various respiratory: eupnea, biot, bradypnea, sighing, tachypnea, and kussmaul. The variations in Channel State Information produced by human respiratory were utilised to identify distinct respiratory patterns using fine-grained Orthogonal Frequency-Division Multiplexing signals. The proposed platform based on the SDR and the Deep Multilayer Perceptron classifier exhibits the ability to effectively detect and classify the afore-mentioned distinct respiratory with an accuracy of up to 99%. Moreover, the effectiveness of the proposed scheme in terms of diagnosis accuracy, precision, recall, F1-score, and confusion matrix is demonstrated by comparison with a state-of-the-art machine learning classifier: Random Forest.

16 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
NZNuobei Zhang
Nuobei Zhang
HLHaoxuan Li
Haoxuan Li
AZAdnan Zahid
Adnan Zahid
Yue TianYue Tian
Yue Tian
Wenda LiWenda Li
Wenda Li
People counting and occupancy monitoring play a vital role in applications such as intelligent building management, safety control, and resource optimization in future smart cities. Conventional camera and infrared-based methods often suffer from privacy risks, lighting dependency, and limited robustness in complex indoor environments. In this paper, we present a 60 GHz millimeter-wave (mmWave) radar-based occupancy monitoring system that enables accurate and privacy-preserving people counting. The proposed system leverages echo signals processed through Doppler and range spectrogram and analyzed by an enhanced ResNet-50 deep learning model to classify motion states and count individuals. Experimental results collected in a typical indoor environment demonstrate that the system achieves 95.45% accuracy across 6 classes of movements and 98.86% accuracy for people counting (0–3 persons). The method also shows strong adaptability under limited data and robustness to Gaussian blur interference, providing an efficient and reliable solution for intelligent indoor occupancy monitoring.

1 February 2023 in arXiv
Verified
Preprint
Open access
PDF file
ZYZheqi Yu
Zheqi Yu
CZChao Zhang
Chao Zhang
Pedro MachadoPedro Machado
Pedro Machado
AZAdnan Zahid
Adnan Zahid
TFTim. Fernandez-Hart
Tim. Fernandez-Hart
Qammer AbbasiQammer Abbasi
Qammer Abbasi
The growing demand for optimal and low-power energy consumption paradigms for Internet of Things (IoT) devices has garnered significant attention due to their cost-effectiveness, simplicity, and intelligibility. We propose an Artificial Intelligence (AI) hardware energy-efficient framework to achieve optimal energy savings in heterogeneous computing through appropriate power consumption management. A deep reinforcement learning framework is employed, utilizing the Actor-Critic architecture to provide a simple and precise method for power saving. The results of the study demonstrate the proposed approach's suitability for different hardware configurations, achieving notable energy consumption control while adhering to strict performance requirements. The evaluation of the proposed power-saving framework shows that it is more stable, and has achieved more than 23% efficiency improvement, outperforming other methods by more than 5%.